Determination of cadmium and lead in high purity uranium compounds by flame atomic absorption spectrometry with on-line micro-column preconcentration by CL-7301 resin

被引:8
|
作者
Li, Bo-ping [1 ]
Luo, Ming-biao [1 ]
Li, Jiang-qiang [1 ]
Liu, Wei [1 ]
Sun, Yu-zhen [1 ]
Guo, Guo-long [1 ]
机构
[1] E China Inst Technol, Key Lab Nucl Resources & Environm, Minist Educ, Fuzhou 344000, JX, Peoples R China
关键词
D O I
10.1007/s10967-007-7175-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line solid phase micro-column extraction and determination system for trace Cd and Pb in nuclear fuel grade uranium compounds was established. The preconcentration of trace elements Cd and Pb from uranium compounds was achieved by adsorbing Cd and Pb on CL-7301 resin in hydroiodic acid media, while the uranyl ion passed through. The method coupled with flame atomic absorption spectrometry (FAAS) was applied to analysis trace Cd and Pb in real samples. The preconcentration factors obtained by this method were 320 and 180 each for Cd and Pb, respectively. Under the optimized conditions, the detection limits corresponding to three times the standard deviation of the blank were found to be 0.13 ng center dot mL(-1) and 0.37 ng center dot mL(-1) for Cd and Pb, respectively. The relative standard deviation (RSD) and the recoveries of standard addition (spiked with 1-5 ng of Cd and Pb) were of < 5% (n = 10) and 96.2%-102.3%, respectively. Precision was also evaluated and found to be <= 4.3% (N = 11). The proposed method was successfully used for the determination of trace Cd and Pb in commercially available uranium compounds (e.g., uranyl acetate and triuranium octoxide).
引用
收藏
页码:3 / 8
页数:6
相关论文
共 50 条
  • [1] Determination of cadmium and lead in high purity uranium compounds by flame atomic absorption spectrometry with on-line micro-column preconcentration by CL-7301 resin
    Bo-ping Li
    Ming-biao Luo
    Jiang-qiang Li
    Wei Liu
    Yu-zhen Sun
    Guo-long Guo
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 278 : 3 - 8
  • [2] Determination of lead and calcium by using combination of flame atomic absorption spectrometry with micro-column preconcentration
    Liu, WH
    Hu, W
    Zhou, ZM
    Zhao, L
    Zhao, F
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (08) : 925 - 927
  • [3] Determination of cadmium by combination of flame atomic absorption spectrometry with graphite particulate micro-column of electrochemical preconcentration
    Liu, WH
    Tan, JH
    Zhang, D
    Fu, Q
    Shan, SY
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (01) : 117 - 119
  • [4] Determination of lead by on-line solid phase extraction using a PTFE micro-column and flame atomic absorption spectrometry
    Zachariadis, GA
    Anthemidis, AN
    Bettas, PG
    Stratis, JA
    TALANTA, 2002, 57 (05) : 919 - 927
  • [5] On-line preconcentration system using a mini-column of activated carbon for cadmium and lead determination in water by flame atomic absorption spectrometry
    Quinaia, Sueli Percio
    Ezequiel Rollembergb, Maria do Carmo
    Borba da Silva, Jose Bento
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2006, 51 (05): : 225 - 233
  • [6] On-line preconcentration system for cadmium determination in environmental samples by flame atomic absorption spectrometry
    Soylak, M
    Narin, I
    CHEMIA ANALITYCZNA, 2005, 50 (04): : 705 - 715
  • [7] Automatic on-line column preconcentration system for determination of cadmium by electrothermal atomic absorption spectrometry
    Alonso, EIV
    Gil, LP
    Cordero, MTS
    de Torres, AG
    Pavón, JMC
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (03) : 293 - 295
  • [8] An on-line separation and preconcentration system coupled with flame atomic absorption spectrometry for the determination of lead
    Dasbasi, Teslima
    Sacmaci, Serife
    Sahan, Serkan
    Ulgen, Ahmet
    Kartal, Senol
    ANALYTICAL METHODS, 2013, 5 (13) : 3307 - 3313
  • [9] Determination of Bi in high-purity lead and cadmium metals by flame atomic absorption spectrometry after on-line matrix separation
    Wu, XZ
    Liu, P
    Pu, QS
    Su, ZX
    CHEMIA ANALITYCZNA, 2002, 47 (05): : 713 - 723
  • [10] A sequential injection on-line column preconcentration system for determination of cadmium by electrothermal atomic absorption spectrometry
    Xu, ZR
    Pan, HY
    Xu, SK
    Fang, ZL
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (03) : 213 - 219