ECHO DECORRELATION IMAGING OF RABBIT LIVER AND VX2 TUMOR DURING IN VIVO ULTRASOUND ABLATION

被引:19
|
作者
Fosnight, Tyler R. [1 ]
Hooi, Fong Ming [1 ]
Keil, Ryan D. [1 ]
Ross, Alexander P. [1 ]
Subramanian, Swetha [1 ]
Akinyi, Teckla G. [1 ]
Killin, Jakob K. [1 ]
Barthe, Peter G. [2 ]
Rudich, Steven M. [3 ]
Ahmad, Syed A. [4 ]
Rao, Marepalli B. [1 ,5 ]
Mast, T. Douglas [1 ]
机构
[1] Univ Cincinnati, Biomed Engn, 231 Albert Sabin Way,ML 0586, Cincinnati, OH 45267 USA
[2] Guided Therapy Syst Ardent Sound, Mesa, AZ USA
[3] Gift Life Michigan, Ann Arbor, MI USA
[4] Univ Cincinnati, Surg, 231 Albert Sabin Way,ML 0586, Cincinnati, OH 45267 USA
[5] Univ Cincinnati, Environm Hlth, 231 Albert Sabin Way,ML 0586, Cincinnati, OH 45267 USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2017年 / 43卷 / 01期
基金
美国国家卫生研究院;
关键词
Echo decorrelation imaging; Therapy monitoring; Thermal ablation; Bulk ultrasound ablation; High-intensity focused ultrasound; INTENSITY FOCUSED ULTRASOUND; RADIO-FREQUENCY ABLATION; MOTION; MANAGEMENT; SYSTEM; TISSUE;
D O I
10.1016/j.ultrasmedbio.2016.08.025
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In open surgical procedures, image-ablate ultrasound arrays performed thermal ablation and imaging on rabbit liver lobes with implanted VX2 tumor. Treatments included unfocused (bulk ultrasound ablation, N = 10) and focused (high-intensity focused ultrasound ablation, N = 13) exposure conditions. Echo decorrelation and integrated backscatter images were formed from pulse-echo data recorded during rest periods after each therapy pulse. Echo decorrelation images were corrected for artifacts using decorrelation measured prior to ablation. Ablation prediction performance was assessed using receiver operating characteristic curves. Results revealed significantly increased echo decorrelation and integrated backscatter in both ablated liver and ablated tumor relative to unablated tissue, with larger differences observed in liver than in tumor. For receiver operating characteristic curves computed from all ablation exposures, both echo decorrelation and integrated backscatter predicted liver and tumor ablation with statistically significant success, and echo decorrelation was significantly better as a predictor of liver ablation. These results indicate echo decorrelation imaging is a successful predictor of local thermal ablation in both normal liver and tumor tissue, with potential for real-time therapy monitoring. (E-mail: doug.mast@uc.edu) (C) 2016 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:176 / 186
页数:11
相关论文
共 50 条
  • [31] Optimized Echo Decorrelation Imaging Feedback for Bulk Ultrasound Ablation Control
    Abbass, Mohamed A.
    Garbo, Allison-Joy
    Mahalingam, Neeraja
    Killin, Jakob K.
    Mast, T. Douglas
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (10) : 1743 - 1755
  • [32] Ultrasound Monitoring of In Vitro Radio Frequency Ablation by Echo Decorrelation Imaging
    Mast, T. Douglas
    Pucke, Daniel P.
    Subramanian, Swetha E.
    Bowus, William J.
    Rudich, Steven M.
    Buell, Joseph F.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (12) : 1685 - 1697
  • [33] Transcatheter arterial chemoembolization (TACE) with iRGD peptide in rabbit VX2 liver tumor
    Liu, Xianchuang
    Xie, Yang
    Qi, Xun
    Xu, Ke
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2020, 16 (07) : 1703 - 1709
  • [34] Doxorubicin nanobubble for combining ultrasonography and targeted chemotherapy of rabbit with VX2 liver tumor
    Meng, Mingming
    Gao, Jie
    Wu, Chongchong
    Zhou, Xuan
    Zang, Xuefeng
    Lin, Xiangchun
    Liu, Hong
    Wang, Canghai
    Su, Hui
    Liu, Kuiliang
    Wang, Yadan
    Xue, Xinying
    Wu, Jing
    TUMOR BIOLOGY, 2016, 37 (07) : 8673 - 8680
  • [35] SUPER-RESOLUTION ULTRASOUND LOCALIZATION MICROSCOPY ON A RABBIT LIVER VX2 TUMOR MODEL: AN INITIAL FEASIBILITY STUDY
    Zhang, Wei
    Lowerison, Matthew R.
    Dong, Zhijie
    Miller, Rita J.
    Keller, Krista A.
    Song, Pengfei
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (08): : 2416 - 2429
  • [36] Preparation of microspheres encapsulating sorafenib and catalase and their application in rabbit VX2 liver tumor
    Li, Xihan
    Yu, Hui
    Huang, Ying
    Chen, Yu
    Wang, Jialun
    Xu, Lei
    Zhang, Feng
    Zhuge, Yuzheng
    Zou, Xiaoping
    BIOMEDICINE & PHARMACOTHERAPY, 2020, 129
  • [37] Diffusion-weighted magnetic resonance imaging to evaluate microvascular density after transarterial embolization ablation in a rabbit VX2 liver tumor model
    Qian, Ting
    Chen, Maozhen
    Gao, Feng
    Meng, Fanhua
    Gao, Xiaohui
    Yin, Huabin
    MAGNETIC RESONANCE IMAGING, 2014, 32 (08) : 1052 - 1057
  • [38] TUMOR TARGETING BY ARTERIAL ADMINISTRATION OF LIPIDS - RABBIT MODEL WITH VX2 CARCINOMA IN THE LIVER
    IWAI, K
    MAEDA, H
    KONNO, T
    MATSUMURA, Y
    YAMASHITA, R
    YAMASAKI, K
    HIRAYAMA, S
    MIYAUCHI, Y
    ANTICANCER RESEARCH, 1987, 7 (03) : 321 - 327
  • [39] MICROSCOPIC ANALYSIS OF ARTERIAL MICROSPHERE DISTRIBUTION IN RABBIT LIVER AND HEPATIC VX2 TUMOR
    PILLAI, KM
    MCKEEVER, PE
    KNUTSEN, CA
    TERRIO, PA
    PRIESKORN, DM
    ENSMINGER, WD
    SELECTIVE CANCER THERAPEUTICS, 1991, 7 (02): : 39 - 48
  • [40] Theranostic application of lipiodol for transarterial chemoembolization in a VX2 rabbit liver tumor model
    van Breugel, Johanna Maria Mijntje
    Geschwind, Jean-Francois
    Mirpour, Sahar
    Savic, Lynn Jeanette
    Zhang, Xuchen
    Duran, Rafael
    Lin, MingDe
    Miszczuk, Milena
    Liapi, Eleni
    Chapiro, Julius