ECHO DECORRELATION IMAGING OF RABBIT LIVER AND VX2 TUMOR DURING IN VIVO ULTRASOUND ABLATION

被引:19
|
作者
Fosnight, Tyler R. [1 ]
Hooi, Fong Ming [1 ]
Keil, Ryan D. [1 ]
Ross, Alexander P. [1 ]
Subramanian, Swetha [1 ]
Akinyi, Teckla G. [1 ]
Killin, Jakob K. [1 ]
Barthe, Peter G. [2 ]
Rudich, Steven M. [3 ]
Ahmad, Syed A. [4 ]
Rao, Marepalli B. [1 ,5 ]
Mast, T. Douglas [1 ]
机构
[1] Univ Cincinnati, Biomed Engn, 231 Albert Sabin Way,ML 0586, Cincinnati, OH 45267 USA
[2] Guided Therapy Syst Ardent Sound, Mesa, AZ USA
[3] Gift Life Michigan, Ann Arbor, MI USA
[4] Univ Cincinnati, Surg, 231 Albert Sabin Way,ML 0586, Cincinnati, OH 45267 USA
[5] Univ Cincinnati, Environm Hlth, 231 Albert Sabin Way,ML 0586, Cincinnati, OH 45267 USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2017年 / 43卷 / 01期
基金
美国国家卫生研究院;
关键词
Echo decorrelation imaging; Therapy monitoring; Thermal ablation; Bulk ultrasound ablation; High-intensity focused ultrasound; INTENSITY FOCUSED ULTRASOUND; RADIO-FREQUENCY ABLATION; MOTION; MANAGEMENT; SYSTEM; TISSUE;
D O I
10.1016/j.ultrasmedbio.2016.08.025
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In open surgical procedures, image-ablate ultrasound arrays performed thermal ablation and imaging on rabbit liver lobes with implanted VX2 tumor. Treatments included unfocused (bulk ultrasound ablation, N = 10) and focused (high-intensity focused ultrasound ablation, N = 13) exposure conditions. Echo decorrelation and integrated backscatter images were formed from pulse-echo data recorded during rest periods after each therapy pulse. Echo decorrelation images were corrected for artifacts using decorrelation measured prior to ablation. Ablation prediction performance was assessed using receiver operating characteristic curves. Results revealed significantly increased echo decorrelation and integrated backscatter in both ablated liver and ablated tumor relative to unablated tissue, with larger differences observed in liver than in tumor. For receiver operating characteristic curves computed from all ablation exposures, both echo decorrelation and integrated backscatter predicted liver and tumor ablation with statistically significant success, and echo decorrelation was significantly better as a predictor of liver ablation. These results indicate echo decorrelation imaging is a successful predictor of local thermal ablation in both normal liver and tumor tissue, with potential for real-time therapy monitoring. (E-mail: doug.mast@uc.edu) (C) 2016 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:176 / 186
页数:11
相关论文
共 50 条
  • [21] Quantitative Study of Elasticity of Rabbit VX2 Liver Tumor with Alternated Cooling and Heating Treatment based on ARFI Ultrasound Imaging Technique
    Di Sun
    Cong Wei
    E. Shen
    Tao Ying
    Bing Hu
    Scientific Reports, 6
  • [22] Quantitative Study of Elasticity of Rabbit VX2 Liver Tumor with Alternated Cooling and Heating Treatment based on ARFI Ultrasound Imaging Technique
    Sun, Di
    Wei, Cong
    Shen, E.
    Ying, Tao
    Hu, Bing
    SCIENTIFIC REPORTS, 2016, 6
  • [23] HEMOCOAGULASE COMBINED WITH MICROBUBBLE-ENHANCED ULTRASOUND CAVITATION FOR AUGMENTED ABLATION OF MICROVASCULATURE IN RABBIT VX2 LIVER TUMORS
    Yang, Qian
    Tang, Peng
    He, Guangbin
    Ge, Shuping
    Liu, Liwen
    Zhou, Xiaodong
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (08): : 1658 - 1670
  • [24] Radio-frequency tissue ablation of VX2 tumor nodules in the rabbit lung
    Goldberg, SN
    Gazelle, GS
    Compton, CC
    Mueller, PR
    McLoud, TC
    ACADEMIC RADIOLOGY, 1996, 3 (11) : 929 - 935
  • [25] SSTR2-based reporter imaging in a rabbit VX2 tumor model
    Ravoori, Murali
    Han, Lin
    Singh, Sheela
    Dixon, Katherine
    Duggal, Jyoti
    Uthamanthil, Rajesh
    Gupta, Sanjay
    Wright, Kenneth
    Kundra, Vikas
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [26] Percutaneous Ultrasound Guided Implantation of VX2 for Creation of a Rabbit Hepatic Tumor Model
    White, Sarah B.
    Chen, Jeane
    Gordon, Andrew C.
    Harris, Kathleen R.
    Nicolai, Jodi R.
    West, Derek L.
    Larson, Andrew C.
    PLOS ONE, 2015, 10 (04):
  • [27] Dependence of ultrasound echo decorrelation on local tissue temperature during ex vivo radiofrequency ablation
    Subramanian, Swetha
    Schmidt, Daniel T.
    Rao, Marepalli B.
    Mast, T. Douglas
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (06): : 2356 - 2371
  • [28] Efficacy of MR-guided focused ultrasound thermal ablation of rabbit VX2 tumors
    Yin, Xiangtao
    Zhang, Yongzhi
    Tam, Karen
    McDannold, Nathan
    Hynynen, Kullervo
    THERAPEUTIC ULTRASOUND, 2006, 829 : 491 - +
  • [29] Quantitative Proton MR Spectroscopy as a Biomarker of Tumor Necrosis in the Rabbit VX2 Liver Tumor
    Buijs, Manon
    Vossen, Josephina A.
    Geschwind, Jean-Francois H.
    Salibi, Nouha
    Pan, Li
    Ventura, Veronica Prieto
    Liapi, Eleni
    Lee, Kwang Hun
    Kamel, Ihab R.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (08) : 1175 - 1180
  • [30] ENDOLYMPHATIC BCG THERAPY IN RABBIT VX2 TUMOR
    EDWARDS, JM
    ODONNELL, TF
    JOHNSON, H
    RUTT, D
    KINMONTH, JB
    SURGICAL FORUM, 1975, 26 : 147 - 149