SINGLE-CELL LEVEL MEASUREMENT OF SHAPE, SHEAR STRESS DISTRIBUTION AND GENE EXPRESSION OF ENDOTHELIAL CELLS IN MICROFLUIDIC CHIPS

被引:0
|
作者
Rossi, Massimiliano [1 ]
Lindken, Ralph [1 ]
Hierck, Beerend P.
Westerweel, Jerry [1 ]
机构
[1] Delft Univ Technol, Lab Aero & Hydrodynam, Delft, Netherlands
关键词
FLOW; SYSTEM;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
A measurement technique based on micro-PIV that allows a non-intrusive, non-tactile determination of the topography and shear stress distribution on endothelial cell cultures with a super-cell resolution is presented. The cells are grown in microfluidic perfusion chips where constant steady flow is applied. The expression of shear responsive gene KLF2 of individual cells is measured simultaneously with the shape and shear stress distribution of the same cell. Due to the super-cell resolution of the technique we can study the correlation of the measured quantities in different parts within the cell such as the nucleus or the cytoplasm. Results on human and chicken endothelial cells are shown.
引用
收藏
页码:1093 / 1098
页数:6
相关论文
共 50 条
  • [31] Aggregating transcript-level analyses for single-cell differential gene expression
    Becht, Etienne
    Zhao, Edward
    Amezquita, Robert
    Gottardo, Raphael
    NATURE METHODS, 2020, 17 (06) : 583 - +
  • [32] Beyond comparisons of means: understanding changes in gene expression at the single-cell level
    Vallejos, Catalina A.
    Richardson, Sylvia
    Marioni, John C.
    GENOME BIOLOGY, 2016, 17
  • [33] Microfluidic single-cell real-time PCR for comparative analysis of gene expression patterns
    Sanchez-Freire, Veronica
    Ebert, Antje D.
    Kalisky, Tomer
    Quake, Stephen R.
    Wu, Joseph C.
    NATURE PROTOCOLS, 2012, 7 (05) : 829 - 838
  • [34] Microfluidic single-cell real-time PCR for comparative analysis of gene expression patterns
    Veronica Sanchez-Freire
    Antje D Ebert
    Tomer Kalisky
    Stephen R Quake
    Joseph C Wu
    Nature Protocols, 2012, 7 : 829 - 838
  • [35] A microfluidic platform for high-purity separating circulating tumor cells at the single-cell level
    Wang, Kun
    Zhou, Lin
    Zhao, Simin
    Cheng, Zule
    Qiu, Shihui
    Lu, Yunxing
    Wu, Zhenhua
    Wahab, Abdel Hady A. Abdel
    Mao, Hongju
    Zhao, Jianlong
    TALANTA, 2019, 200 : 169 - 176
  • [36] Receding meniscus induced docking of yeast cells inside microfluidic channels at single-cell level
    Park, Min Cheol
    Hur, Jae Young
    Kwon, Keon Woo
    Park, Jee Won
    Park, Sang-Hyun
    Suh, Kahp Y.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 246 - +
  • [37] Single-cell level array of yeast cells in pumpless microfluidic channels induced by receding meniscus
    Park, Min Cheol
    Hur, Jae Young
    Kwon, Keon Woo
    Park, Sang-Hyun
    Suh, Kahp Y.
    2006 IEEE SENSORS, VOLS 1-3, 2006, : 638 - +
  • [38] A novel microfluidic chip integrated with Pt micro-thermometer for temperature measurement at the single-cell level
    Chen, Kai
    Liang, Baihui
    Yang, Ping
    Li, Min
    Yuan, Haojun
    Wu, Jinlei
    Gao, Wanlei
    Jin, Qinghui
    HELIYON, 2024, 10 (09)
  • [39] SHEAR-STRESS INDUCES EXPRESSION OF CNP GENE IN HUMAN ENDOTHELIAL-CELLS
    OKAHARA, K
    KAMBAYASHI, J
    OHNISHI, T
    FUJIWARA, Y
    KAWASAKI, T
    MONDEN, M
    FEBS LETTERS, 1995, 373 (02) : 108 - 110
  • [40] Gene expression profile of human endothelial cells exposed to sustained fluid shear stress
    Wasserman, SM
    Mehraban, F
    Komuves, LG
    Yang, RB
    Tomlinson, JE
    Zhang, Y
    Spriggs, F
    Topper, JN
    PHYSIOLOGICAL GENOMICS, 2002, 12 (01) : 13 - 23