A novel microfluidic chip integrated with Pt micro-thermometer for temperature measurement at the single-cell level

被引:1
|
作者
Chen, Kai [1 ,4 ]
Liang, Baihui [2 ,3 ]
Yang, Ping [1 ]
Li, Min [1 ]
Yuan, Haojun [1 ]
Wu, Jinlei [1 ]
Gao, Wanlei [1 ,4 ,5 ]
Jin, Qinghui [1 ,4 ]
机构
[1] Ningbo Univ, Coll Informat Sci & Engn, Ningbo 315211, Zhejiang, Peoples R China
[2] Hlth & Intelligent Kitchen Engn Res Ctr Zhejiang P, Ningbo 315336, Zhejiang, Peoples R China
[3] Ningbo Fotile Kitchen Ware Co, Ningbo 315336, Zhejiang, Peoples R China
[4] Chinese Acad Sci, State Key Lab Transducer Technol, Shanghai Inst Microsyst & Informat Technol, Shanghai 200050, Peoples R China
[5] Ningbo Univ, Fac Elect Engn & Comp Sci, Ningbo 315211, Zhejiang, Peoples R China
关键词
Single cell isolation; Pt electrode-based thermometer; Microfluidic chip; In-situ temperature detection; Tumor cell analysis;
D O I
10.1016/j.heliyon.2024.e30649
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Noninvasive and sensitive thermometry of a single cell during the normal physiological process is crucial for analyzing fundamental cellular metabolism and applications to cancer treatment. However, current thermometers generally sense the average temperature variation for many cells, thereby failing to obtain real-time and continuous data of an individual cell. In this study, we employed platinum (Pt) electrodes to construct an integrated microfluidic chip as a single-cell thermometer. The single-cell isolation unit in the microchip consisted of a main channel, which was connected to the inlet and outlet of a single-cell capture funnel. A single cell can be trapped in the funnel and the remaining cells can bypass and flow along the main channel to the outlet. The best capture ratio of a single MCF7 cell at a single-cell isolation unit was 90 % under optimal condition. The thermometer in the micro-chip had a temperature resolution of 0.007 degrees C and showed a good linear relationship in the range of 20-40 degrees C (R2 = 0.9999). Slight temperature increment of different single tumor cell (MCF7 cell, H1975 cell, and HepG2 cell) cultured on the chip was continuously recorded under normal physiological condition. In addition, the temperature variation of single MCF7 cell in-situ after exposure to a stimulus (4 % paraformaldehyde treatment) was also monitored, showing an amplitude of temperature fluctuations gradually decreased over time. Taken together, this integrated microchip is a practical tool for detecting the change in the temperature of a single cell in real-time, thereby offering valuable information for the drug screening, diagnosis, and treatment of cancer.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Microfluidic Chip for Detection of Drug Resistance at the Single-cell Level
    Song, Kena
    Yu, Zhangqing
    Zu, Xiangyang
    Huang, Lei
    Fu, Dongliao
    Yao, Jingru
    Hu, Zhigang
    Xue, Yun
    MICROMACHINES, 2023, 14 (01)
  • [2] A Microfluidic Chip for Screening and Sequencing of Monoclonal Antibody at a Single-Cell Level
    Zhang, Weikai
    Li, Qin
    Jia, Fei
    Hu, Zhiyuan
    Wei, Zewen
    ANALYTICAL CHEMISTRY, 2021, 93 (29) : 10099 - 10105
  • [3] Measurement of Single-Cell Deformability Using Impedance Analysis on Microfluidic Chip
    Kim, Dongil
    Choi, Eunpyo
    Choi, Sung Sik
    Lee, Sangho
    Park, Jungyul
    Yun, Kwang-Seok
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2010, 49 (12)
  • [4] Single-cell sorting using integrated pneumatic valve droplet microfluidic chip
    Zhou, Yang
    Yu, Zhibin
    Wu, Man
    Lan, Yuwei
    Jia, Chunping
    Zhao, Jianlong
    TALANTA, 2023, 253
  • [5] Single-cell metabolite analysis on a microfluidic chip
    Wang, Chenlong
    Hu, Wanting
    Guan, Liandi
    Yang, Xiaoping
    Liang, Qionglin
    CHINESE CHEMICAL LETTERS, 2022, 33 (06) : 2883 - 2892
  • [6] Microfluidic Chip for Single-cell Interaction Anaysis
    Hsu, Chia-Hsien
    2019 13TH IEEE INTERNATIONAL CONFERENCE ON NANO/MOLECULAR MEDICINE & ENGINEERING (IEEE-NANOMED 2019), 2019, : 57 - 58
  • [7] Single-cell metabolite analysis on a microfluidic chip
    Chenlong Wang
    Wanting Hu
    Liandi Guan
    Xiaoping Yang
    Qionglin Liang
    Chinese Chemical Letters, 2022, 33 (06) : 2883 - 2892
  • [8] A MICROFLUIDIC CHIP FOR SCREENING HIGH-PRODUCING HYBRIDOMAS AT THE SINGLE-CELL LEVEL
    Zhang, Wei K.
    Li, Ren
    Fang, Zhi G.
    Hu, Zhi Y.
    Wei, Ze W.
    Li, Qin
    2019 IEEE 32ND INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2019, : 422 - 425
  • [9] Multilayer electrodes DEP chip for single-cell level impedance measurement
    Chuang, Cheng-Hsin
    Wei, Ching-Hua
    Hsu, You-Ming
    Lu, Jian-Tang
    2007 2ND IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1-3, 2007, : 568 - +
  • [10] Tunable microfluidic chip for single-cell deformation study
    Ruiyun Zhang
    Xuexin Duan
    Shuaihua Zhang
    Wenlan Guo
    Chen Sun
    Ziyu Han
    Nanotechnology and Precision Engineering, 2023, 6 (02) : 29 - 36