A novel microfluidic chip integrated with Pt micro-thermometer for temperature measurement at the single-cell level

被引:1
|
作者
Chen, Kai [1 ,4 ]
Liang, Baihui [2 ,3 ]
Yang, Ping [1 ]
Li, Min [1 ]
Yuan, Haojun [1 ]
Wu, Jinlei [1 ]
Gao, Wanlei [1 ,4 ,5 ]
Jin, Qinghui [1 ,4 ]
机构
[1] Ningbo Univ, Coll Informat Sci & Engn, Ningbo 315211, Zhejiang, Peoples R China
[2] Hlth & Intelligent Kitchen Engn Res Ctr Zhejiang P, Ningbo 315336, Zhejiang, Peoples R China
[3] Ningbo Fotile Kitchen Ware Co, Ningbo 315336, Zhejiang, Peoples R China
[4] Chinese Acad Sci, State Key Lab Transducer Technol, Shanghai Inst Microsyst & Informat Technol, Shanghai 200050, Peoples R China
[5] Ningbo Univ, Fac Elect Engn & Comp Sci, Ningbo 315211, Zhejiang, Peoples R China
关键词
Single cell isolation; Pt electrode-based thermometer; Microfluidic chip; In-situ temperature detection; Tumor cell analysis;
D O I
10.1016/j.heliyon.2024.e30649
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Noninvasive and sensitive thermometry of a single cell during the normal physiological process is crucial for analyzing fundamental cellular metabolism and applications to cancer treatment. However, current thermometers generally sense the average temperature variation for many cells, thereby failing to obtain real-time and continuous data of an individual cell. In this study, we employed platinum (Pt) electrodes to construct an integrated microfluidic chip as a single-cell thermometer. The single-cell isolation unit in the microchip consisted of a main channel, which was connected to the inlet and outlet of a single-cell capture funnel. A single cell can be trapped in the funnel and the remaining cells can bypass and flow along the main channel to the outlet. The best capture ratio of a single MCF7 cell at a single-cell isolation unit was 90 % under optimal condition. The thermometer in the micro-chip had a temperature resolution of 0.007 degrees C and showed a good linear relationship in the range of 20-40 degrees C (R2 = 0.9999). Slight temperature increment of different single tumor cell (MCF7 cell, H1975 cell, and HepG2 cell) cultured on the chip was continuously recorded under normal physiological condition. In addition, the temperature variation of single MCF7 cell in-situ after exposure to a stimulus (4 % paraformaldehyde treatment) was also monitored, showing an amplitude of temperature fluctuations gradually decreased over time. Taken together, this integrated microchip is a practical tool for detecting the change in the temperature of a single cell in real-time, thereby offering valuable information for the drug screening, diagnosis, and treatment of cancer.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Microfluidic integrated optoelectronic tweezers for single-cell preparation and analysis
    Huang, Kuo-Wei
    Wu, Yi-Chien
    Lee, Ji-Ann
    Chiou, Pei-Yu
    LAB ON A CHIP, 2013, 13 (18) : 3721 - 3727
  • [32] Erratum: Integrated microfluidic device for single-cell trapping and spectroscopy
    C. Liberale
    G. Cojoc
    F. Bragheri
    P. Minzioni
    G. Perozziello
    R. La Rocca
    L. Ferrara
    V. Rajamanickam
    E. Di Fabrizio
    I. Cristiani
    Scientific Reports, 3
  • [33] Profiling lymphocyte interactions at the single-cell level by microfluidic cell pairing
    Burak Dura
    Stephanie K. Dougan
    Marta Barisa
    Melanie M. Hoehl
    Catherine T. Lo
    Hidde L. Ploegh
    Joel Voldman
    Nature Communications, 6
  • [34] Profiling lymphocyte interactions at the single-cell level by microfluidic cell pairing
    Dura, Burak
    Dougan, Stephanie K.
    Barisa, Marta
    Hoehl, Melanie M.
    Lo, Catherine T.
    Ploegh, Hidde L.
    Voldman, Joel
    NATURE COMMUNICATIONS, 2015, 6
  • [35] Measurement and Modeling of Signaling at the Single-Cell Level
    Kolitz, Sarah E.
    Lauffenburger, Douglas A.
    BIOCHEMISTRY, 2012, 51 (38) : 7433 - 7443
  • [36] Micro-sized syringes for single-cell fluidic access integrated on a micro-electrode array CMOS chip
    Huys, Roeland
    Braeken, Dries
    Micholt, Liesbeth
    Jans, Danny
    Stassen, Andim
    Collaert, Nadine
    Loo, Josine
    Bartic, Carmen
    Verstreken, Kris
    Eberle, Wolfgang
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 7650 - 7653
  • [37] AM-DMF-SCP: Integrated Single-Cell Proteomics Analysis on an Active Matrix Digital Microfluidic Chip
    Yang, Zhicheng
    Jin, Kai
    Chen, Yimin
    Liu, Qian
    Chen, Hongxu
    Hu, Siyi
    Wang, Yuqiu
    Pan, Zilu
    Feng, Fang
    Shi, Mude
    Xie, Hua
    Ma, Hanbin
    Zhou, Hu
    JACS AU, 2024, 4 (05): : 1811 - 1823
  • [38] Measurement of single-cell adhesion strength using a microfluidic assay
    Christ, Kevin V.
    Williamson, Kyle B.
    Masters, Kristyn S.
    Turner, Kevin T.
    BIOMEDICAL MICRODEVICES, 2010, 12 (03) : 443 - 455
  • [39] Measurement of single-cell adhesion strength using a microfluidic assay
    Kevin V. Christ
    Kyle B. Williamson
    Kristyn S. Masters
    Kevin T. Turner
    Biomedical Microdevices, 2010, 12 : 443 - 455
  • [40] Microfluidic Chip-Based Automatic System for Sequencing Patient-Derived Organoids at the Single-Cell Level
    Wu, Xin
    Li, Bowen
    Wang, Yadong
    Xue, Jianchao
    Zhao, Huiting
    Huang, Zhicheng
    Zheng, Zhibo
    Liang, Naixin
    Wei, Zewen
    ANALYTICAL CHEMISTRY, 2024, 96 (42) : 17027 - 17036