Comparative performance analysis of fruit fly optimisation algorithm for multi-area multi-source automatic generation control under deregulated environment

被引:74
|
作者
Mohanty, Banaja [1 ]
Hota, Prakash Kumar [1 ]
机构
[1] Veer Surendra Sai Univ Technol, Dept Elect Engn, Burla 768018, Odisha, India
关键词
power system interconnection; hydrothermal power systems; nuclear power stations; power generation control; electricity supply industry deregulation; optimisation; three-term control; PI control; sensitivity analysis; thermal power stations; comparative performance analysis; fruit fly optimisation algorithm; multiarea multisource automatic generation control; deregulated environment; swarm optimisation algorithm; multiarea multisource interconnected power system; reheat thermal generating unit; hydro generating unit; nuclear generating unit; generation rate constraint; AC-DC link; proportional-integral controller; integral controller; proportional-integral-derivative controller; integral-double derivative controller; proportional-integral-double derivative controller; PIDD controller; IDD controller; system parameter variation; LOAD FREQUENCY CONTROL; POWER-SYSTEM; AGC; SIMULATION; MODEL;
D O I
10.1049/iet-gtd.2015.0284
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new swarm optimisation algorithm, that is, fruit fly optimisation algorithm is proposed to tuned several classical controllers for multi-area multi-source interconnected power system under deregulated environment. In deregulated environment, for multi-source combination of reheat thermal, hydro and nuclear generating units in each control area with appropriate generation rate constraint and AC/DC link. The performance of several controller such as integral (I), proportional-integral, proportional-integral-derivative, integral-double derivative (IDD) and proportional-integral-double derivative (PIDD) are compared under different power system scenario and it is found that PIDD controller performs better than other controllers. Then sensitivity analysis is performed with system parameter variation from their nominal values. Sensitivity analysis reveals that optimum gains of PIDD controller need not be reset for wide variation in system parameters.
引用
收藏
页码:1845 / 1855
页数:11
相关论文
共 50 条
  • [41] Mitigation of cyber-physical attacks in multi-area automatic generation control
    Alhalali, Safoan
    Nielsen, Christopher
    ElShatshat, Ramadan
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 112 : 362 - 369
  • [42] The application of ANN technique to automatic generation control for multi-area power system
    Zeynelgil, HL
    Demiroren, A
    Sengor, NS
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2002, 24 (05) : 345 - 354
  • [43] Recent Strategies for Automatic Generation Control of Multi-Area Interconnected Power Systems
    Kumar, Ashwini
    Singh, Omveer
    [J]. 2019 3RD INTERNATIONAL CONFERENCE ON RECENT DEVELOPMENTS IN CONTROL, AUTOMATION & POWER ENGINEERING (RDCAPE), 2019, : 153 - 158
  • [44] Load-Frequency Control of Multi-Area Power System Based on the Improved Weighted Fruit Fly Optimization Algorithm
    Wang, Nian
    Zhang, Jing
    He, Yu
    Liu, Min
    Zhang, Ying
    Chen, Chaokuan
    Gu, Yerui
    Ren, Yongheng
    [J]. ENERGIES, 2020, 13 (02)
  • [45] Combined Voltage and Frequency Control of a Multi-Area Multi-Source System Using SFLA Optimized TID Controller
    Babu, Naladi Ram
    Sahu, Devesh Kumar
    Saikia, Lalit Chandra
    Ramoji, Satish Kumar
    [J]. 2019 IEEE 16TH INDIA COUNCIL INTERNATIONAL CONFERENCE (IEEE INDICON 2019), 2019,
  • [46] AGC of a multi-area thermal system under deregulated environment using a non-integer controller
    Debbarma, Sanjoy
    Saikia, Lalit Chandra
    Sinha, Nidul
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2013, 95 : 175 - 183
  • [47] A Review and Advance Technology in Multi-Area Automatic Generation Control by Using Minority Charge Carrier Inspired Algorithm
    Madichetty, Sreedhar
    Panda, Susmita
    Mishra, Sambeet
    Dasgupta, Abhijit
    [J]. INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2013, 14 (06) : 609 - 627
  • [48] A Novel Robust Automatic Generation Control in Interconnected Multi-Area Power System Based on Bat Inspired Algorithm
    Kouba, Nour El Yakine
    Menaa, Mohamed
    Hasni, Mourad
    Boudour, Mohamed
    [J]. 3RD INTERNATIONAL CONFERENCE ON CONTROL, ENGINEERING & INFORMATION TECHNOLOGY (CEIT 2015), 2015,
  • [49] Firefly algorithm optimized fuzzy PID controller for AGC of multi-area multi-source power systems with UPFC and SMES
    Pradhan, Pratap Chandra
    Sahu, Rabindra Kumar
    Panda, Sidhartha
    [J]. ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2016, 19 (01): : 338 - 354
  • [50] Dandelion Optimizer-Based Combined Automatic Voltage Regulation and Load Frequency Control in a Multi-Area, Multi-Source Interconnected Power System with Nonlinearities
    Ali, Tayyab
    Malik, Suheel Abdullah
    Daraz, Amil
    Aslam, Sheraz
    Alkhalifah, Tamim
    [J]. ENERGIES, 2022, 15 (22)