Comparative performance analysis of fruit fly optimisation algorithm for multi-area multi-source automatic generation control under deregulated environment

被引:74
|
作者
Mohanty, Banaja [1 ]
Hota, Prakash Kumar [1 ]
机构
[1] Veer Surendra Sai Univ Technol, Dept Elect Engn, Burla 768018, Odisha, India
关键词
power system interconnection; hydrothermal power systems; nuclear power stations; power generation control; electricity supply industry deregulation; optimisation; three-term control; PI control; sensitivity analysis; thermal power stations; comparative performance analysis; fruit fly optimisation algorithm; multiarea multisource automatic generation control; deregulated environment; swarm optimisation algorithm; multiarea multisource interconnected power system; reheat thermal generating unit; hydro generating unit; nuclear generating unit; generation rate constraint; AC-DC link; proportional-integral controller; integral controller; proportional-integral-derivative controller; integral-double derivative controller; proportional-integral-double derivative controller; PIDD controller; IDD controller; system parameter variation; LOAD FREQUENCY CONTROL; POWER-SYSTEM; AGC; SIMULATION; MODEL;
D O I
10.1049/iet-gtd.2015.0284
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new swarm optimisation algorithm, that is, fruit fly optimisation algorithm is proposed to tuned several classical controllers for multi-area multi-source interconnected power system under deregulated environment. In deregulated environment, for multi-source combination of reheat thermal, hydro and nuclear generating units in each control area with appropriate generation rate constraint and AC/DC link. The performance of several controller such as integral (I), proportional-integral, proportional-integral-derivative, integral-double derivative (IDD) and proportional-integral-double derivative (PIDD) are compared under different power system scenario and it is found that PIDD controller performs better than other controllers. Then sensitivity analysis is performed with system parameter variation from their nominal values. Sensitivity analysis reveals that optimum gains of PIDD controller need not be reset for wide variation in system parameters.
引用
收藏
页码:1845 / 1855
页数:11
相关论文
共 50 条
  • [31] Maiden Application of Coyote Optimizer Algorithm with TIDN Controller in AGC of a Multi-Area Multi-Source System
    Babu, Naladi Ram
    Narrisetty, Varun
    Saikia, Lalit Chandra
    [J]. 2019 IEEE 16TH INDIA COUNCIL INTERNATIONAL CONFERENCE (IEEE INDICON 2019), 2019,
  • [32] A Novel Approach for Automatic Generation Control of a Multi-Area Power System
    Khuntia, Swasti R.
    Panda, Sidhartha
    [J]. 2011 24TH CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (CCECE), 2011, : 1182 - 1187
  • [33] LFC of an interconnected power system with multi-source power generation in deregulated power environment
    Parmar, K. P. Singh
    Majhi, S.
    Kothari, D. P.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 57 : 277 - 286
  • [34] Performance Enhancement of Automatic Generation Control for a Multi-Area Power System in the Presence of Communication Delay
    Rahimi, Kaveh
    Famouri, Parviz
    [J]. 2013 NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2013,
  • [35] MFO algorithm based fuzzy-PID controller in Automatic generation control of multi-area system
    Sahu, Prakash Chandra
    Prusty, Ramesh Chandra
    Panda, Sidhartha
    [J]. PROCEEDINGS OF 2017 IEEE INTERNATIONAL CONFERENCE ON CIRCUIT ,POWER AND COMPUTING TECHNOLOGIES (ICCPCT), 2017,
  • [36] Iterative LMI-Tuned PID Controller for Robust Decentralized Multi-Area Automatic Generation Control in Deregulated Electricity Markets
    Anuoluwapo, Gbadega Peter
    Yanxia, Sun
    [J]. INTERNATIONAL JOURNAL OF ENGINEERING RESEARCH IN AFRICA, 2024, 71 : 109 - 140
  • [37] Power Flow Analysis Considering Automatic Generation Control for Multi-Area Interconnection Power Networks
    Dong, Xiaoming
    Sun, Hua
    Wang, Chengfu
    Yun, Zhihao
    Wang, Yiming
    Zhao, Penghui
    Ding, Yuanyuan
    Wang, Yong
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (06) : 5200 - 5208
  • [38] Load Frequency Control of a Multi-area, Multi-source System Using Firefly Algorithm Optimized F2DOFIDD Controller
    Sarma, Upasana
    Saikia, Lalit Chandra
    Saha, Arindita
    Dash, Puja
    [J]. PROCEEDINGS OF THE 2016 IEEE REGION 10 CONFERENCE (TENCON), 2016, : 1475 - 1479
  • [39] Quasi oppositional harmony search algorithm based controller tuning for load frequency control of multi-source multi-area power system
    Shankar, G.
    Mukherjee, V.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 75 : 289 - 302
  • [40] Automatic Generation Control of Multi-area Hydro System Using Classical Controllers
    Saikia, Lalit Chandra
    Bharali, A.
    Dixit, O.
    Malakar, T.
    Sharma, B.
    Kouli, S.