An Adaptive Calibration Method for Parallel ADC Acquisition System

被引:0
|
作者
Ma Yufei [1 ]
Chen Gang [1 ]
机构
[1] Shenyang Ligong Univ, Fac Informat Sci & Engn, Shenyang 110159, Peoples R China
关键词
Parallel ADC Sampling; Non-uniform Errors; Adaptive; Calibration;
D O I
10.1109/ICMTMA.2013.50
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
At present, a commonly used method for increasing the sampling rate is multi-chip ADC in parallel time-interleaved sampling, in theory, which is improving the sampling rate. However, in practical applications, the mismatch between the channel due to the chip ADC is not fully same leading the splicing signal to non-uniform sampling signal, severely reducing the performance of the sampling system. Based on the characteristics of non-uniform errors of the parallel ADC sampling system, establishing the basic model of non-uniform errors estimation and correction. In this paper, a improved variable step LMS adaptive algorithm is applied. In the Matlab environment, simulation experiment show that this method realized the comprehensive correction of non-uniform errors, and is feasible and practical.
引用
收藏
页码:170 / 173
页数:4
相关论文
共 50 条
  • [31] A sampling ADC data acquisition system for positron emission tomography
    Mann, A
    Grube, B
    Konorov, I
    Paul, S
    Schmitt, L
    McElroy, DP
    Ziegler, SI
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 296 - 300
  • [32] A HIGH-SPEED ADC FOR RABBIT SYSTEM DATA ACQUISITION
    OLIVER, J
    BLOCKER, C
    KESTEN, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) : 236 - 239
  • [33] Simultaneous sampling ADC data acquisition system for the QUIET experiment
    Bogdan, Mircea
    Samtleben, Dorothea
    Vanderlinde, Keith
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1077 - 1079
  • [34] Adaptive calibration method for camera distortion
    Huang, Chiung-Wei
    Chou, Chang-Min
    Lin, Ting-Wei
    Chang, Cheng-Yuan
    JOURNAL OF VIBRATION AND CONTROL, 2013, 19 (01) : 86 - 93
  • [35] Subband Adaptive Reconstruction Method Based on Digital Bandwidth Interleaving Acquisition System
    Chen, Zhihong
    Ye, Peng
    Yang, Kuojun
    Chen, Li
    Ming, Ruiyuan
    Chen, Aijun
    Zheng, Zhiyu
    Li, Chengyang
    Wei, Ming
    2024 IEEE AUTOTESTCON, 2024,
  • [36] Accurate calibration method for a fringe projection system by projecting an adaptive fringe pattern
    Gonzalez, Andres
    Meneses, Jaime
    APPLIED OPTICS, 2019, 58 (17) : 4610 - 4615
  • [37] Method of data acquisition by a group of parallel interfaces
    Liu, Zhengxi
    Tao, Shiguang
    Fan, Yixiang
    Hedianzixue Yu Tance Jishu/Nuclear Electronics & Detection Technology, 2000, 20 (02): : 154 - 156
  • [38] An improved parallel acquisition method for BDS signals
    Li, Jian, 1600, China Spaceflight Society (35):
  • [39] A Calibration Method of Compliant Planar Parallel Manipulator
    Lin, Jian-feng
    Qi, Chen-kun
    Wu, Yu-ze
    Gao, Feng
    INTELLIGENT ROBOTICS AND APPLICATIONS, ICIRA 2021, PT II, 2021, 13014 : 257 - 266
  • [40] A direct calibration method for line structured light measurement system based on parallel lines
    Wang, Zhaoxu
    Fu, Yanjun
    Zhong, Kejun
    Li, Ye
    Bao, Wei
    OPTICS COMMUNICATIONS, 2022, 508