Potential thermal artifacts in hip joint wear simulators

被引:1
|
作者
Lu, Z [1 ]
McKellop, H
Liao, P
Benya, P
机构
[1] Los Angeles Orthopaed Hosp, J Vernon Luck Orthopaed Res Ctr, Los Angeles, CA USA
[2] Univ So Calif, Sch Med, Dept Orthopaed, Los Angeles, CA 90033 USA
[3] Univ So Calif, Dept Biomed Engn, Los Angeles, CA 90089 USA
来源
关键词
wear; hip prosthesis; polyethylene; frictional heat; hip simulator;
D O I
10.1002/(SICI)1097-4636(1999)48:4<458::AID-JBM9>3.3.CO;2-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Frictional heat was monitored during wear tests of ultrahigh molecular weight polyethylene acetabular cups bearing against femoral balls of metal or ceramic in a hip simulator, using bovine serum as a lubricant. About 1 to 2 h of continuous cycling were required for the temperature in the zone of contact between the cup and ball to rise to its maximum steady value, and this equilibrium temperature was markedly higher with increased load and/or cycling rate, Frictional heating caused substantial precipitation of the proteins from the serum and, in some of the tests running at 1.5 or 2 Hz, an adherent proteinaceous layer was observed attached to the surface of the balls. The maximum temperature was also substantially higher in tests run with the cup mounted above the ball rather than below. Surprisingly, the tests running at higher frictional torque and temperature (i.e., those with the most protein precipitation and/or adherent layers) produced the least wear of. the polyethylene. This might have been due to the solid proteins that formed a protective layer between the ball and cup. Because patients with hip prostheses typically do not walk for hours without rest, the maximum temperatures irt vivo are likely to be much lower than those reached in the hip simulator, Therefore, the affects of protein precipitation on the resultant wear properties of the materials should be considered potential artifacts of the hip simulator tests. Increasing the volume of the lubricant bath reduced the maximum temperatures for tests running at 1.5 Nz but had little affect at 2 Hz. Reducing the cycling rate is an effective way to avoid overheating of the specimens, but this necessarily extends the time required to complete a test. (C) 1999 John Wiley & Sons, Inc.
引用
收藏
页码:458 / 464
页数:7
相关论文
共 50 条
  • [41] A multi-station hip joint simulator study and wear characterization of commercial hip endoprostheses
    Jono, K
    Takigawa, Y
    Takadama, H
    Mizuno, M
    Nakamura, T
    27TH INTERNATIONAL COCOA BEACH CONFERENCE ON ADVANCED CERAMICS AND COMPOSITES: A, 2003, 24 (03): : 255 - 260
  • [42] Three-axis hip joint simulator for wear and friction studies on total hip prostheses
    Saikko, Vesa O.
    Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1996, 210 (03) : 175 - 185
  • [43] Potential of wear resistant coatings on Ti-6Al-4V for artificial hip joint bearing surfaces
    Oesterle, W.
    Klaffke, D.
    Griepentrog, M.
    Gross, U.
    Kranz, I.
    Knabe, Ch.
    WEAR, 2008, 264 (7-8) : 505 - 517
  • [44] Micro-Raman spectroscopy for the crystallinity characterization of UHMWPE hip cups run on joint simulators
    Bertoluzza, A
    Fagnano, C
    Rossi, M
    Tinti, A
    Cacciari, GL
    JOURNAL OF MOLECULAR STRUCTURE, 2000, 521 : 89 - 95
  • [45] Wear tests in a hip joint simulator of different CoCrMo counterfaces on UHMWPE
    Gonzalez-Mora, V. A.
    Hoffmann, M.
    Stroosnijder, R.
    Gil, F. J.
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2009, 29 (01): : 153 - 158
  • [46] FRICTION AND WEAR STUDIES ON TOTAL HIP-JOINT REPLACEMENT PROSTHESES
    SIMON, SR
    WEIGHTMA.BO
    PAUL, IL
    ROSE, RM
    RADIN, EL
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (03): : 661 - &
  • [47] Frictional heating of bearing materials tested in a hip joint wear simulator
    Lu, Z
    McKellop, H
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (01) : 101 - 108
  • [49] Numerical wear simulation of artificial hip joint: tribological behaviour of UHMWPE
    Almohallami, A.
    Bouguecha, A.
    Stukenborg-Colsman, C.
    Lerch, M.
    Nolte, I
    Behrens, B-A
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S1170 - S1171
  • [50] Lubrication modeling and wear calculation in artificial hip joint during the gait
    Ruggiero, Alessandro
    Sicilia, Alessandro
    TRIBOLOGY INTERNATIONAL, 2020, 142