Reliability of computer-assisted retinal vessel measurement in a population

被引:123
|
作者
Sherry, LM
Wang, JJ
Rochtchina, E
Wong, TY
Klein, R
Hubbard, LD
Mitchell, P
机构
[1] Univ Sydney, Westmead Hosp, Dept Ophthalmol, Ctr Vis Res, Westmead, NSW 2145, Australia
[2] Univ Sydney, Westmead Millennium Inst, Sydney, NSW 2006, Australia
[3] Univ Sydney, Save Sight Inst, Sydney, NSW 2006, Australia
[4] Univ Wisconsin, Dept Ophthalmol & Visual Sci, Madison, WI USA
来源
关键词
grading; intragrader agreement; intergrader agreement; quadratic weighted kappa statistic; reliability; retinal vessel width;
D O I
10.1046/j.1442-9071.2002.00520.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The purpose of the study was to assess the intergrader and intragrader reliability of computer-assisted retinal vessel dia-meter measurement in a defined, community-based population. Retinal photographs from participants in the Blue Mountains Eye Study were digitized using standard techniques. A grader identified all retinal vessels located 0.5-1.0 disc diameter from the optic disc margin, and a computer program measured the width of these vessels. Intergrader and intragrader reliability was assessed on a random sub-sample of 184 and 97 images, respectively, using quadratic weighted kappa (kappa) and correlation analysis (R-2). Intergrader reliability was high for summary indices of retinal arteriolar (kappa = 0.85, R (2) = 0.88) and venular (kappa = 0.90, R-2 = 0.90) diameters, and their ratio, the arteriole-to-venule ratio (kappa = 0.75, R-2 = 0.79). Intragrader reliability was also high, with kappa values ranging from 0.80 to 0.93 and from 0.80 to 0.92 for graders 1 and 2, respectively. It is concluded that the retinal vessel diameters could be reliably measured using computer-assisted software and may be used for population-based research.
引用
收藏
页码:179 / 182
页数:4
相关论文
共 50 条
  • [41] COMPUTER-ASSISTED HIGH-VOLTAGE WAVEFORM MEASUREMENT
    WALTER, CW
    MCMILLIAN, GB
    SMITH, KA
    DUNNING, FB
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (11): : 2171 - 2172
  • [42] COMPUTER-ASSISTED METHOD FOR SPEECH PRECISION AND CONSISTENCY MEASUREMENT
    PISANI, R
    TOSI, O
    BERTACCINI, G
    FOLIA PHONIATRICA, 1992, 44 (1-2): : 63 - 64
  • [43] COMPUTER-ASSISTED LEUKOCYTE ADHESION MEASUREMENT IN INTRAVITAL MICROSCOPY
    ZEINTL, H
    SACK, FU
    INTAGLIETTA, M
    MESSMER, K
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1989, 8 (03): : 293 - 302
  • [44] COMPUTER-ASSISTED MEASUREMENT OF PERIPHERAL-BLOOD FLOW
    MCCULLAGH, PJ
    MCALLISTER, HG
    MCCAFFREY, PM
    FOX, JS
    TAGGART, AJ
    RIDDELL, JG
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1988, 12 (01) : 7 - 14
  • [45] Smart Computer-Assisted Cognitive Rehabilitation for the Ageing Population
    Oliver, Miguel
    Gonzalez, Pascual
    Montero, Francisco
    Pascual Molina, Jose
    Fernandez-Caballero, Antonio
    AMBIENT INTELLIGENCE - SOFTWARE AND APPLICATIONS (ISAMI 2016), 2016, 476 : 197 - 205
  • [46] Reliability and objectivity of computer-assisted myotonometry in the region of lumbar musculature
    Brockow, T
    Schreiber, U
    Smolenski, U
    Loth, D
    Unbehauen, P
    Callies, R
    PHYSIKALISCHE MEDIZIN REHABILITATIONSMEDIZIN KURORTMEDIZIN, 1996, 6 (06) : 217 - 222
  • [47] INCREASING THE RELIABILITY OF COMPUTER-ASSISTED BINDING PARAMETER-ESTIMATION
    TOTHFALUSI, L
    MAGYAR, K
    PHARMACOLOGICAL RESEARCH, 1992, 25 : 89 - 90
  • [48] Reliability analysis framework for computer-assisted medical decision systems
    Habas, Piotr A.
    Zurada, Jacek M.
    Elmaghraby, Adel S.
    Tourassi, Georgia D.
    MEDICAL PHYSICS, 2007, 34 (02) : 763 - 772
  • [49] A RELIABILITY STUDY OF COMPUTER-ASSISTED IMPLANT RELATED BONE LEVELS
    HABSHA, E
    CHAYTOR, DV
    ZARB, GA
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 111 - 111
  • [50] INTERRATER RELIABILITY OF COMPUTER-ASSISTED SCORING OF BREATHING DURING SLEEP
    LORD, S
    SAWYER, B
    POND, D
    OCONNELL, D
    EYLAND, A
    MANT, A
    HENSLEY, MJ
    SAUNDERS, NA
    SLEEP, 1989, 12 (06) : 550 - 558