Reliability of computer-assisted retinal vessel measurement in a population

被引:123
|
作者
Sherry, LM
Wang, JJ
Rochtchina, E
Wong, TY
Klein, R
Hubbard, LD
Mitchell, P
机构
[1] Univ Sydney, Westmead Hosp, Dept Ophthalmol, Ctr Vis Res, Westmead, NSW 2145, Australia
[2] Univ Sydney, Westmead Millennium Inst, Sydney, NSW 2006, Australia
[3] Univ Sydney, Save Sight Inst, Sydney, NSW 2006, Australia
[4] Univ Wisconsin, Dept Ophthalmol & Visual Sci, Madison, WI USA
来源
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY | 2002年 / 30卷 / 03期
关键词
grading; intragrader agreement; intergrader agreement; quadratic weighted kappa statistic; reliability; retinal vessel width;
D O I
10.1046/j.1442-9071.2002.00520.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The purpose of the study was to assess the intergrader and intragrader reliability of computer-assisted retinal vessel dia-meter measurement in a defined, community-based population. Retinal photographs from participants in the Blue Mountains Eye Study were digitized using standard techniques. A grader identified all retinal vessels located 0.5-1.0 disc diameter from the optic disc margin, and a computer program measured the width of these vessels. Intergrader and intragrader reliability was assessed on a random sub-sample of 184 and 97 images, respectively, using quadratic weighted kappa (kappa) and correlation analysis (R-2). Intergrader reliability was high for summary indices of retinal arteriolar (kappa = 0.85, R (2) = 0.88) and venular (kappa = 0.90, R-2 = 0.90) diameters, and their ratio, the arteriole-to-venule ratio (kappa = 0.75, R-2 = 0.79). Intragrader reliability was also high, with kappa values ranging from 0.80 to 0.93 and from 0.80 to 0.92 for graders 1 and 2, respectively. It is concluded that the retinal vessel diameters could be reliably measured using computer-assisted software and may be used for population-based research.
引用
收藏
页码:179 / 182
页数:4
相关论文
共 50 条
  • [31] Reliability of light microscopy and a computer-assisted replica measurement technique for evaluating the fit of dental copings
    Rudolph, Heike
    Ostertag, Silke
    Ostertag, Michael
    Walter, Michael H.
    Luthardt, Ralph Gunnar
    Kuhn, Katharina
    JOURNAL OF APPLIED ORAL SCIENCE, 2018, 26
  • [32] Design and development of a computer-assisted retinal laser surgery system
    Wright, Cameron H. G.
    Barrett, Steven F.
    Welch, Ashley J.
    JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (04)
  • [33] HERETAIN - A COMPUTER-ASSISTED DIAGNOSIS SYSTEM FOR INHERITED RETINAL DISEASES
    DEBBASCH, JM
    DARMONI, SJ
    LEBBE, J
    VIGNES, R
    COSCAS, G
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1993, 16 (6-7): : 392 - 396
  • [34] Computer-Assisted Cobb Angle Measurement on Posteroanterior Radiographs
    Zhang, J.
    Lou, E.
    Le, L. H.
    Hill, D.
    Raso, J.
    Wang, Y.
    RESEARCH INTO SPINAL DEFORMITIES 6, 2008, 140 : 151 - +
  • [35] IMAGE MEASUREMENT TECHNIQUES UTILIZING A COMPUTER-ASSISTED COMPARATOR
    HELMERING, RJ
    PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 1979, 45 (06): : 786 - 786
  • [36] FOCUS ON MICROSCOPY - MEASUREMENT IN THE AGE OF COMPUTER-ASSISTED MICROSCOPY
    FOSTER, BM
    MILLER, WI
    AMERICAN LABORATORY, 1994, 26 (17) : 54 - 57
  • [37] MODEL FOR COMPUTER-ASSISTED CRITERION-REFERENCED MEASUREMENT
    FERGUSON, RL
    EDUCATION, 1970, 91 (01): : 25 - 31
  • [38] ONLINE PORTAL IMAGING - COMPUTER-ASSISTED ERROR MEASUREMENT
    LAM, WC
    HERMAN, MG
    LAM, KS
    LEE, DJ
    RADIOLOGY, 1991, 179 (03) : 871 - 873
  • [39] COMPUTER-ASSISTED MEASUREMENT OF RIGIDITY FOR DIFFERENTIATION OF PSYCHOPATHOLOGICAL GROUPS
    GRUNBERGER, J
    LINZMAYER, L
    STOHR, H
    WITTEK, R
    SALETU, B
    WIENER MEDIZINISCHE WOCHENSCHRIFT, 1988, 138 (09) : 206 - 212
  • [40] COMPUTER-ASSISTED MEASUREMENT OF FULL VENEER CROWN TAPER
    NOLAN, K
    CASSIDY, M
    JOURNAL OF DENTAL RESEARCH, 1989, 68 (04) : 584 - 584