Reliability of computer-assisted retinal vessel measurement in a population

被引:121
|
作者
Sherry, LM
Wang, JJ
Rochtchina, E
Wong, TY
Klein, R
Hubbard, LD
Mitchell, P
机构
[1] Univ Sydney, Westmead Hosp, Dept Ophthalmol, Ctr Vis Res, Westmead, NSW 2145, Australia
[2] Univ Sydney, Westmead Millennium Inst, Sydney, NSW 2006, Australia
[3] Univ Sydney, Save Sight Inst, Sydney, NSW 2006, Australia
[4] Univ Wisconsin, Dept Ophthalmol & Visual Sci, Madison, WI USA
来源
关键词
grading; intragrader agreement; intergrader agreement; quadratic weighted kappa statistic; reliability; retinal vessel width;
D O I
10.1046/j.1442-9071.2002.00520.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The purpose of the study was to assess the intergrader and intragrader reliability of computer-assisted retinal vessel dia-meter measurement in a defined, community-based population. Retinal photographs from participants in the Blue Mountains Eye Study were digitized using standard techniques. A grader identified all retinal vessels located 0.5-1.0 disc diameter from the optic disc margin, and a computer program measured the width of these vessels. Intergrader and intragrader reliability was assessed on a random sub-sample of 184 and 97 images, respectively, using quadratic weighted kappa (kappa) and correlation analysis (R-2). Intergrader reliability was high for summary indices of retinal arteriolar (kappa = 0.85, R (2) = 0.88) and venular (kappa = 0.90, R-2 = 0.90) diameters, and their ratio, the arteriole-to-venule ratio (kappa = 0.75, R-2 = 0.79). Intragrader reliability was also high, with kappa values ranging from 0.80 to 0.93 and from 0.80 to 0.92 for graders 1 and 2, respectively. It is concluded that the retinal vessel diameters could be reliably measured using computer-assisted software and may be used for population-based research.
引用
收藏
页码:179 / 182
页数:4
相关论文
共 50 条
  • [1] Computer-assisted retinal vessel measurement in an older population: correlation between right and left eyes
    Leung, H
    Wang, JJ
    Rochtchina, E
    Tan, AG
    Wong, TY
    Hubbard, LD
    Klein, R
    Mitchell, P
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2003, 31 (04): : 326 - 330
  • [2] COMPUTER-ASSISTED MEASUREMENT OF VESSEL DIAMETER AND BLOOD VELOCITY
    GOODMAN, AH
    [J]. MICROVASCULAR RESEARCH, 1980, 19 (02) : 249 - 249
  • [3] Computer-Assisted Evaluation of Retinal Vessel Diameter in Retinitis Pigmentosa
    Sodi, Andrea
    Mucciolo, Dario Pasquale
    Murro, Vittoria
    Zoppetti, Claudia
    Terzuoli, Bianca
    Mecocci, Alessandro
    Virgili, Gianni
    Rizzo, Stanislao
    [J]. OPHTHALMIC RESEARCH, 2016, 56 (03) : 139 - 144
  • [4] Computer-assisted retinal vessel diameter evaluation in Fabry disease
    Sodi, Andrea
    Nicolosi, Cristina
    Vicini, Giulio
    Lenzetti, Chiara
    Virgili, Gianni
    Rizzo, Stanislao
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (01) : 173 - 178
  • [5] Computer-Assisted Measurement of Retinal Vascular Width and Tortuosity in Retinopathy of Prematurity
    Kiely, Amanda E.
    Wallace, David K.
    Freedman, Sharon F.
    Zhao, Zheen
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2010, 128 (07) : 847 - 852
  • [6] Computer-assisted evaluation of retinal vessel tortuosity in moderate-to-late preterm children
    Raffa, Lina
    Abudawd, Ola
    Bugshan, Nada
    Fageeh, Samiha
    Ramos, Lucia
    Novo, Jorge
    Rouco, Jose
    Ortega, Marcos
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (05) : 1874 - 1882
  • [7] COMPUTER-ASSISTED ACCUMULATION OF RELIABILITY INFORMATION
    MORRIS, JD
    [J]. EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1979, 39 (03) : 645 - 647
  • [8] A comparative study on the repeatability and reliability between the manual and computer-assisted cephalometric measurement
    Iacob, Mihnea
    Cozma, Danut
    Zetu, Irina Nicoleta
    [J]. 2013 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2013,
  • [9] Computer-assisted Cobb measurement of scoliosis
    Nachiappan Chockalingam
    Peter H. Dangerfield
    Giannis Giakas
    Tom Cochrane
    John C. Dorgan
    [J]. European Spine Journal, 2002, 11 : 353 - 357
  • [10] COMPUTER-ASSISTED MEASUREMENT OF REPLICON AUTORADIOGRAMS
    MASON, DC
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 1978, 8 (03) : 177 - 186