Comparison of Sensor Detection Sensitivity in Repetitive Partial Discharge Inception Voltage Measurement for Twisted Pair Placed in Stator

被引:0
|
作者
Nakamura, Keigo [1 ]
Uchimura, Tomoki [1 ]
Kozako, Masahiro [1 ]
Hikita, Masayuki [1 ]
Ueno, Takahisa [2 ]
Sun, Jintong [3 ]
Sakurai, Takayuki [3 ]
Nakayama, Kazuhisa [3 ]
Ikegami, Tomomi [3 ]
Karasawa, Kazunari [3 ]
机构
[1] Kyushu Inst Technol, Fac Engn, Dept Elect Engn & Elect, 1-1 Sensui Cho, Kitakyushu, Fukuoka, Japan
[2] Oita Coll, Natl Inst Technol, Dept Elect & Elect Engn, 1666 Oaza Maki, Oita, Japan
[3] Toshiba Mitsubishi Elect Ind Syst Corp, Chuo Ku, Tokyo Sq Garden,3-1-1 Kyobashi, Tokyo, Japan
关键词
Inverter surge; repetitive partial discharge; inception voltage; twisted pair; electromagnetic sensor; Stator;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
RPDIV (Repetitive Partial Discharge Inception Voltage) measurement becomes essential to fulfill a certificate test according to IEC60034-18-41IS for inverter-fed motor. In measurement of RPDIV, electromagnetic antenna is often used as a PD sensor. Thus, the detection sensitivity of the sensor is crucial to properly determine RPDIV. This paper deals with sensitivity comparison between kinds of electromagnetic sensors and a PD measuring device connected to a measurement circuit for RPDIV measurement of twisted pair placed in stator.
引用
收藏
页码:239 / 242
页数:4
相关论文
共 50 条
  • [41] Using partial discharge measurement technology to implement predictive maintenance in high voltage motor and generator stator windings
    Stone, G
    Kapler, J
    1997 IEEE/PCA CEMENT INDUSTRY TECHNICAL CONFERENCE - XXXIX CONFERENCE RECORD, 1997, : 63 - 68
  • [42] Comparison between RF and electrical signals from the partial discharge activity of twisted pair cables at reduced pressures
    Given, M. J.
    Mason, R.
    Judd, M.
    McGlone, P.
    Timoshkin, I. V.
    Wilson, M. P.
    2011 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS 1 AND 2, 2011, : 514 - 517
  • [43] Partial Discharge Detection of High Voltage Switchgear Using a Ultra High Frequency Sensor
    Shin, Jong-Yeol
    Lee, Young-Sang
    Hong, Jin-Woong
    TRANSACTIONS ON ELECTRICAL AND ELECTRONIC MATERIALS, 2013, 14 (04) : 211 - 215
  • [44] Design of UHF Antenna Sensor for Partial Discharge Detection in High Voltage S ubstation
    Mukhtar, Sharulnizam Mohd
    Isa, Muzamir
    Al-Hadi, Azremi Abdullah
    MALAYSIAN TECHNICAL UNIVERSITIES CONFERENCE ON ENGINEERING AND TECHNOLOGY 2017 (MUCET 2017), 2018, 318
  • [45] A fiber optic sensor for the detection of Partial Discharge within the High Voltage power transformer
    Sarkar, B.
    Koley, C.
    Roy, N. K.
    Kumbhakar, P.
    FOUNDATIONS AND FRONTIERS IN COMPUTER, COMMUNICATION AND ELECTRICAL ENGINEERING, 2016, : 177 - 181
  • [46] Study of Polarization Sensitivity of UHF Sensor for Partial Discharge Detection in Gas Insulated Switchgear
    Yadam, Yugandhara Rao
    Ramanujam, Sarathi
    Arunachalam, Kavitha
    IEEE SENSORS JOURNAL, 2023, 23 (02) : 1214 - 1223
  • [47] Partial Discharge Propagation inside a High Voltage Transformer Winding: Comparison of Measurement and Simulation
    Abd Rahman, M. S.
    Rapisarda, P.
    Lewin, P. L.
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 56 - 59
  • [48] Comparison of Partial Discharge Measurement Methods under the Oscillating Lightning Impulse Voltage in GIS
    Liang, Jianfeng
    Zhang, Liang
    Li, Junhao
    Li, Yanming
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 900 - 903
  • [49] Round-Robin Test of Repetitive Partial Discharge Inception Voltage Measurements on Complete Winding of 4 kW Random-Wound Motor
    Kikuchi, Yusuke
    Nagata, Masayoshi
    Kanazawa, Seiji
    Ishida, Takahiro
    Nagao, Masayuki
    Murakami, Yoshinobu
    Ueno, Takahisa
    Hikita, Masayuki
    2016 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2016, : 248 - 251
  • [50] Round-robin test of repetitive partial discharge inception voltage measurements on complete winding of 4 kW random-wound motor
    Univ. of Hyogo, 2167 Shosha, Himeji, Hyogo
    671-2280, Japan
    不详
    437-8555, Japan
    不详
    870-0152, Japan
    不详
    870-119, Japan
    不详
    441-8580, Japan
    不详
    804-8550, Japan
    Electr. Insulation Conf., EIC, (248-251):