Electrooxidation Behavior and Amperometric Determination of Sotalol on a Graphene Oxide Nanosheets-modified Glassy Carbon Electrode

被引:11
|
作者
Heli, Hossein [1 ]
Zare, Seyede Nasrin [2 ]
Sattarahmady, Naghmeh [3 ,4 ,5 ]
Karimian, Khashayar [6 ]
机构
[1] Iranian Space Res Ctr, Inst Mech, Shiraz 7155863333, Iran
[2] Islamic Azad Univ, Firouzabad Branch, Dept Chem, Firouzabad, Iran
[3] Shiraz Univ Med Sci, Sch Med, Dept Med Phys, Shiraz, Iran
[4] Shiraz Univ Med Sci, Sch Pharm, Pharmaceut Sci Res Ctr, Shiraz, Iran
[5] Shiraz Univ Med Sci, Sch Adv Med Sci & Technol, Dept Nanomed, Shiraz, Iran
[6] Arasto Pharmaceut Chem Inc, Tehran, Iran
基金
美国国家科学基金会;
关键词
Graphene; sotalol; modified electrode; electrocatalysis; nanosensor; SENSITIVE DETECTION; NANOCOMPOSITE; NANOPARTICLES; PLASMA; FIBRILLATION; OXIDATION; SENSOR;
D O I
10.2174/1573412911309030007
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The electrochemical behavior of sotalol was investigated on a graphene oxide nanosheets-modified glassy carbon electrode in a phosphate buffer solution, pH 7.4. Cyclic voltammetry and chronoamperometry were employed to obtain information about the electrooxidation process. During the electrooxidation of sotalol, one irreversible anodic peak appeared in the voltammograms. Some kinetic parameters, such as the diffusion and charge transfer coefficients were obtained. An amperometric procedure was developed for the determination of sotalol, a detection limit of 7.57 mu M, a linear dynamic range of 0.1 to 2.24 mM, and a calibration sensitivity of 0.945 mA M-1 were obtained. The method was applied to the analysis of sotalol tablets, and applicability of the method to direct assays of spiked human serum and urine fluids was investigated.
引用
收藏
页码:291 / 298
页数:8
相关论文
共 50 条
  • [11] Electrochemical Behavior and Voltammetric Determination of Curcumin at Electrochemically Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Zhang, Dongdong
    Ouyang, Xiaoyan
    Ma, Jing
    Li, Lingzhi
    Zhang, Yanmin
    ELECTROANALYSIS, 2016, 28 (04) : 749 - 756
  • [12] Study and Electrochemical Determination of Tyrosine at Graphene Nanosheets Composite Film Modified Glassy Carbon Electrode
    Behpour, M.
    Masoum, S.
    Meshki, M.
    JOURNAL OF NANOSTRUCTURES, 2013, 3 (02) : 243 - 251
  • [13] Amperometric Sensing of Hydrogen Peroxide Using Graphene Oxide-Alizarin Modified Glassy Carbon Electrode
    Muhammet, Sinan Mithat
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (06):
  • [14] Amperometric sensing of catechol using a glassy carbon electrode modified with ferrocene covalently immobilized on graphene oxide
    Elancheziyan, Mari
    Manoj, Devaraj
    Saravanakumar, Duraisamy
    Thenmozhi, Kathavarayan
    Senthilkumar, Sellappan
    MICROCHIMICA ACTA, 2017, 184 (08) : 2925 - 2932
  • [15] Amperometric sensing of catechol using a glassy carbon electrode modified with ferrocene covalently immobilized on graphene oxide
    Mari Elancheziyan
    Devaraj Manoj
    Duraisamy Saravanakumar
    Kathavarayan Thenmozhi
    Sellappan Senthilkumar
    Microchimica Acta, 2017, 184 : 2925 - 2932
  • [16] Amperometric nonenzymatic determination of glucose based on a glassy carbon electrode modified with nickel(II) oxides and graphene
    Xiaohua Zhu
    Qifang Jiao
    Chuyi Zhang
    Xiaoxi Zuo
    Xin Xiao
    Yong Liang
    Junmin Nan
    Microchimica Acta, 2013, 180 : 477 - 483
  • [17] Amperometric nonenzymatic determination of glucose based on a glassy carbon electrode modified with nickel(II) oxides and graphene
    Zhu, Xiaohua
    Jiao, Qifang
    Zhang, Chuyi
    Zuo, Xiaoxi
    Xiao, Xin
    Liang, Yong
    Nan, Junmin
    MICROCHIMICA ACTA, 2013, 180 (5-6) : 477 - 483
  • [18] Electrochemical determination of caffeine in beverage using graphene oxide modified glassy carbon electrode
    Murugan, E.
    Poongan, A.
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2021, 28 (05) : 528 - 536
  • [19] Voltammetric Determination of Gallic Acid with a Glassy Carbon Electrode modified with Reduced Graphene Oxide
    Lisnund, Sireerat
    Blay, Vincent
    Chansaenpak, Kantapat
    Pinyou, Piyanut
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (08): : 7214 - 7227
  • [20] Electrochemical determination of adenine using a glassy carbon electrode modified with graphene oxide and polyaniline
    Sharma, Vimal
    Hynek, David
    Trnkova, Libuse
    Hemzal, Dusan
    Marik, Marian
    Kizek, Rene
    Hubalek, Jaromir
    MICROCHIMICA ACTA, 2016, 183 (04) : 1299 - 1306