Echo-time range effects on gradient-echo based myelin water fraction mapping at 3T

被引:10
|
作者
Lee, Hongpyo [1 ]
Nam, Yoonho [2 ]
Kim, Dong-Hyun [1 ]
机构
[1] Yonsei Univ, Dept Elect & Elect Engn, 50 Yonsei Ro, Seoul 03722, South Korea
[2] Catholic Univ Korea, Seoul St Marys Hosp, Dept Radiol, Coll Med, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
IN-VIVO; RELAXATION; FREQUENCY; BRAIN; ORIENTATION; MODEL; VISUALIZATION; ATLAS; MRI;
D O I
10.1002/mrm.27564
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the effect of the range of TE on multi-echo gradient echobased myelin water fraction (MWF) mapping at 3 T. Methods: Myelin water fraction estimation was performed using 3 widely used models: magnitude multipool, magnitude 3-pool, and complex 3-pool model. Simulations were conducted using a hollow cylinder model with susceptibility anisotropy. The TE range was varied, and its effect on MWF estimation was observed. The same analysis was also performed with in vivo data from 4 healthy volunteers. Results: Different MWFs were obtained depending on the range of TE data acquired. In the simulations, the results of both magnitude models had a bias with respect to the true values: a maximum bias of up to 20% for the multipool model, and a maximum bias of up to 8% for the 3-pool model. This bias was reduced using the complex 3-pool model (maximum bias was under 2%). These effects were also found in the in vivo data. The MWF values using the complex model was most stable with respect to the TE range. Conclusion: The results of the simulation and in vivo data suggest that MWF values fitted using magnitude models are more influenced by the TE range collected for fitting than using the complex model. The complex model is helpful in mitigating bias due to dependencies over the TE range selection.
引用
收藏
页码:2799 / 2807
页数:9
相关论文
共 50 条
  • [31] A comparison of multiband and multiband multiecho gradient-echo EPI for task fMRI at 3 T
    Fazal, Zahra
    Gomez, Daniel E. P.
    Llera, Alberto
    Marques, Jose P. R. F.
    Beck, Thomas
    Poser, Benedikt A.
    Norris, David G.
    HUMAN BRAIN MAPPING, 2023, 44 (01) : 82 - 93
  • [32] MS Lesions Are Better Detected with 3D T1 Gradient-Echo Than with 2D T1 Spin-Echo Gadolinium-Enhanced Imaging at 3T
    Crombe, A.
    Saranathan, M.
    Ruet, A.
    Durieux, M.
    de Roquefeuil, E.
    Ouallet, J. C.
    Brochet, B.
    Dousset, V.
    Tourdias, T.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (03) : 501 - 507
  • [33] Microvascular BOLD contribution at 4 and 7 T in the human brain: Gradient-echo and spin-echo fMRI with suppression of blood effects
    Duong, TQ
    Yacoub, E
    Adriany, G
    Hu, XP
    Ugurbil, K
    Kim, SG
    MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (06) : 1019 - 1027
  • [34] Evaluation of optimised 3D turbo spin echo and gradient echo MR pulse sequences of the knee at 3T and 1.5T
    Abdulaal, O. M.
    Rainford, L.
    MacMahon, P. J.
    Kenny, P.
    Carty, F.
    Galligan, M.
    Cradock, A.
    Alhazmi, F. H.
    McGee, A.
    RADIOGRAPHY, 2021, 27 (02) : 389 - 397
  • [35] Optimized multi-echo gradient-echo magnetic resonance imaging for gray and white matter segmentation in the lumbosacral cord at 3 T
    Bueler, Silvan
    Yiannakas, Marios C.
    Damjanovski, Zdravko
    Freund, Patrick
    Liechti, Martina D.
    David, Gergely
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [36] Optimized multi-echo gradient-echo magnetic resonance imaging for gray and white matter segmentation in the lumbosacral cord at 3 T
    Silvan Büeler
    Marios C. Yiannakas
    Zdravko Damjanovski
    Patrick Freund
    Martina D. Liechti
    Gergely David
    Scientific Reports, 12
  • [37] Vascular contributions to pattern analysis: Comparing gradient and spin echo fMRI at 3T
    Thompson, Russell
    Correia, Marta
    Cusack, Rhodri
    NEUROIMAGE, 2011, 56 (02) : 643 - 650
  • [38] Dobutamine stress tagging and gradient-echo imaging for detection of coronary heart disease at 3 T
    Thomas, D.
    Meyer, C.
    Strach, K.
    Naehle, C. P.
    Mazraeh, J.
    Gampert, T.
    Schild, H. H.
    Sommer, T.
    BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (997): : 44 - 50
  • [39] Comparison of Spin-Echo T1-and T2-Weighted and Gradient-Echo T1-Weighted Images at 3T in Evaluating Very Preterm Neonates at Term-Equivalent Age
    Sarikaya, B.
    McKinney, A. M.
    Spilseth, B.
    Truwit, C. L.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (05) : 1098 - 1103
  • [40] Echo time optimization for J-difference editing of glutathione at 3T
    Chan, Kimberly L.
    Puts, Nicolaas A. J.
    Snoussi, Karim
    Harris, Ashley D.
    Barker, Peter B.
    Edden, Richard A. E.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (02) : 498 - 504