Asynchronous Fault Location Scheme Based on Voltage Distribution for Three-Terminal Transmission Lines

被引:14
|
作者
Cao, Pulin [1 ]
Shu, Hongchun [1 ]
Yang, Bo [1 ]
Fang, Yi [2 ]
Han, Yiming [1 ]
Dong, Jun [1 ]
Yu, Tao [3 ]
机构
[1] Kunming Univ Sci & Technol, Fac Elect Power Engn, Kunming 650500, Yunnan, Peoples R China
[2] Yunnan Power Grid Corp, Relay & Protect Dept, Kunming 650000, Yunnan, Peoples R China
[3] South China Univ Technol, Coll Elect Power, Guangzhou 510640, Peoples R China
关键词
Power transmission lines; Fault location; Circuit faults; Synchronization; Impedance; Substations; Voltage distribution; faulty section identification; three-terminal transmission lines; fault location; asynchronous data; PROTECTION TECHNIQUE; CLASSIFICATION;
D O I
10.1109/TPWRD.2020.2971248
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The synchronization of the voltage and current from different terminals is generally unachievable in the power grids at mountainous area, which leads to the fault location method with synchronized data to be impossibly utilized. This paper proposes a voltage distribution based fault location scheme with asynchronous data for three-terminal transmission lines. At first, the faulty section is identified by the voltage computed from each terminal due to the boundaries formed by fault point and tee-point. Since the fault current is stable after the transients decay, the asynchronous calculated voltage and current from the terminals without faults can be synchronized by their angle differences to form the voltage and current at faulty section near the tee-point. Then, the voltage distribution of the faulty section can be obtained from the tee-point and the terminal to find the intersection point of them. In order to fully utilize the fault characteristics in the voltage and current, the earth mode and the minimum of the voltage distribution are applied to optimize the fault location results for grounding faults and multi-phase faults, respectively. Moreover, the robustness of the proposed fault location scheme is thoroughly validated by the simulation of PSCAD/EMTDC. At last, a set of the field data acquired by wave recorders is applied to test the feasibility of the proposed approach.
引用
下载
收藏
页码:2530 / 2540
页数:11
相关论文
共 50 条
  • [41] One-terminal fault location for HVDC flexible transmission lines based on wave voltage distribution features
    Li, D. (lidekun@yeah.net), 1600, Automation of Electric Power Systems Press (37):
  • [42] Setting-free Fault Section Identification and Fault Location Method for Three-terminal Lines
    Naidu, O. D.
    George, Neethu
    Yalla, Preetham
    2019 9TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY SYSTEMS (ICPES), 2019,
  • [43] Fault zone identification method for three-terminal hybrid UHVDC transmission lines based on GRU
    Xing C.
    Wei R.
    Xi X.
    Liu M.
    He X.
    Li S.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (10): : 98 - 109
  • [44] Dynamic fault locator for three-terminal transmission lines for phasor measurement units
    He, Zhengyou Y.
    Li, Xiaopeng P.
    He, Wen
    Liu, Yuping P.
    Zhang, Shu
    Mai, Ruikun K.
    Qian, Qingquan Q.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2013, 7 (02) : 183 - 191
  • [45] Traveling Wave based Adaptive Auto-reclosing and Fault Location for Three-terminal Mixed Lines
    Naidu, O. D.
    Pradhan, A. K.
    Krishnamurthy, Padmasri
    2019 IEEE PES GTD GRAND INTERNATIONAL CONFERENCE AND EXPOSITION ASIA (GTD ASIA), 2019, : 466 - 471
  • [46] A new PMU-based fault location algorithm for three-terminal
    Shen Hong-yu
    Zhang Wen-jun
    Duan Yu-bo
    Xu Jian-jun
    ADVANCES IN CHEMICAL, MATERIAL AND METALLURGICAL ENGINEERING, PTS 1-5, 2013, 634-638 : 3925 - 3929
  • [47] A new fault location method for single-circuit three-terminal transmission lines based onfault branch determination and iterative calculation
    Chen X.
    Yu L.
    Pei D.
    Yuan S.
    Xue S.
    Jiang Y.
    Li S.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2022, 50 (20): : 1 - 11
  • [48] A Synchrophasor-Based Fault Location Method for Three-Terminal Hybrid Transmission Lines With One Off-Service Line Branch
    Lee, Yu-Ju
    Chao, Ching-Hsin
    Lin, Tzu-Chiao
    Liu, Chih-Wen
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (06) : 3249 - 3251
  • [49] Fault location for two- and three-terminal parallel lines using synchronized data
    Stamp, Jason
    Girgis, Adly A.
    International Journal of Power and Energy Systems, 1999, 19 (03): : 212 - 217
  • [50] A fault-location method for application with current differential relays of three-terminal lines
    Izykowski, Jan
    Rosolowski, Eugeniusz
    Saha, Murari Mohan
    Fulezyk, Marek
    Balcerek, Przemyslaw
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (04) : 2099 - 2107