One-terminal fault location for HVDC flexible transmission lines based on wave voltage distribution features

被引:3
|
作者
机构
[1] Song, Guobing
[2] Li, Dekun
[3] Jin, Donghui
[4] Ran, Mengbing
[5] Jin, Xingfu
[6] Guo, Runsheng
来源
Li, D. (lidekun@yeah.net) | 1600年 / Automation of Electric Power Systems Press卷 / 37期
关键词
Refraction - Voltage distribution measurement - HVDC power transmission - Location - Electric fault location - Wavefronts;
D O I
10.7500/AEPS20130221007
中图分类号
学科分类号
摘要
A one-terminal fault location method for high voltage direct current (HVDC) Flexible transmission lines based on distributed parameter model is proposed. As high-capacity capacitors are connected to both ends of HVDC Flexible transmission lines, in the network of one-mode fault component, the voltage travelling waves have the following two features: total reflection of voltage traveling wave occurring at both DC buses of two-terminal HVDC transmission system and at the fault point the refraction of traveling wave stronger than the reflection; the polarity of voltage traveling wave changed due to reflection rather than refraction. Then, the voltage distribution of the first reflected wave at the measuring point and its forward path can be calculated. Finally, the strongest positive switching point in the voltage distribution can be found, and the distance from this point to the opposite terminal is the fault distance. This method has a satisfactory precision and is not affected by transition resistance theoretically. Besides, there is no need to artificially recognize the wave front of the traveling wave and the automation of fault location is easy to implement by use of the proposed algorithm. Simulation results show this method is applicable to the whole line. © 2013 State Grid Electric Power Research Institute Press.
引用
下载
收藏
相关论文
共 50 条
  • [1] Transient Fault Location for HVDC Transmission Lines Based on Voltage Distribution and One-Terminal Information
    Li Bao-de
    Tan Jian-cheng
    2014 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2014,
  • [3] Fault location in transmission lines using one-terminal postfault voltage data
    De Pereira, CE
    Zanetta, LC
    IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (02) : 570 - 575
  • [4] Impedance-traveling wave assembled algorithm of one-terminal fault location for transmission lines
    Zheng, Xiu-Yu
    Ding, Jian-Yong
    Huang, Na
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (06): : 18 - 21
  • [5] Fault Location for Interline Fault of Parallel Transmission Lines Using One-terminal Data
    Xu, Gang
    Yu, Sheng
    Xu, Zhenyu
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 2014 - +
  • [6] Long Transmission Lines Fault Location Based on Parameter Identification Using One-Terminal Data
    Wang, Bin
    Suonan, Jiale
    Liu, Heqing
    Song, Guobing
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [7] Fault location by one-terminal measurement in distribution network
    韩凤玲
    王毅
    董慧峰
    Journal of Harbin Institute of Technology(New series), 2001, (01) : 90 - 93
  • [8] Time-domain fault location algorithm based on one-terminal current of parallel transmission lines
    School of Electric Engineering, Xi'an Jiaotong University, Xi'an 710049, China
    Zhongguo Dianji Gongcheng Xuebao, 2007, 7 (52-57):
  • [9] Study on impedance-traveling wave assembled algorithm in one-terminal fault location system for transmission lines
    Zheng, Xiuyu
    Li, Xiaoming
    Ding, Jianyong
    Duan, Zhiyuan
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 1723 - 1726