beast cancer screening;
cancer risk prediction model;
computer-aided detection for breast cancer;
early cancer detection and treatment;
risk analysis;
BREAST-CANCER RISK;
ASSESSMENT MODELS;
DENSITY;
PERFORMANCE;
RADIOMICS;
FEATURES;
TEXTURE;
MASSES;
WOMEN;
D O I:
10.1586/17434440.2015.1068115
中图分类号:
R318 [生物医学工程];
学科分类号:
0831 ;
摘要:
In this editorial article, we share our visions of how to improve the efficacy of breast cancer screening using quantitative image feature analysis methods with the medical imaging research community. Although earlier cancer detection and treatment can help reduce the mortality rates of patients with breast cancer, the most existing long-term (or lifetime) risk models do not have clinically acceptable discriminatory power at the individual level to select women for current screening. Because of such a clinical dilemma and low efficacy of breast cancer screening, it is of great importance to establish a new and more effective personalized breast cancer screening paradigm. The new computer-aided detection (CAD) approach can be applied in two application fields: analyzing negative mammograms can provide useful information to assess cancer risk, and implementing case-based cancer risk scores can develop an adaptive CAD cueing method to yield higher sensitivity and lower false-positive detection rates.
机构:
Univ Cent Marta Abreu de las Villas, Automat & Comp Syst Dept, Camajuani Rd Km 5 1-2, Santa Clara 52830, CubaUniv Cent Marta Abreu de las Villas, Automat & Comp Syst Dept, Camajuani Rd Km 5 1-2, Santa Clara 52830, Cuba
Perez-Diaz, Marlen
Orozco-Morales, Ruben
论文数: 0引用数: 0
h-index: 0
机构:
Univ Cent Marta Abreu de las Villas, Automat & Comp Syst Dept, Camajuani Rd Km 5 1-2, Santa Clara 52830, CubaUniv Cent Marta Abreu de las Villas, Automat & Comp Syst Dept, Camajuani Rd Km 5 1-2, Santa Clara 52830, Cuba
Orozco-Morales, Ruben
Suarez-Aday, Eduardo
论文数: 0引用数: 0
h-index: 0
机构:
Univ Cent Marta Abreu de las Villas, Automat & Comp Syst Dept, Camajuani Rd Km 5 1-2, Santa Clara 52830, CubaUniv Cent Marta Abreu de las Villas, Automat & Comp Syst Dept, Camajuani Rd Km 5 1-2, Santa Clara 52830, Cuba
Suarez-Aday, Eduardo
Pirchio, Rosana
论文数: 0引用数: 0
h-index: 0
机构:
Atom Energy Natl Commiss, Med Phys Dept, Buenos Aires, DF, ArgentinaUniv Cent Marta Abreu de las Villas, Automat & Comp Syst Dept, Camajuani Rd Km 5 1-2, Santa Clara 52830, Cuba
Pirchio, Rosana
VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING,
2020,
75
: 265
-
271