Power supply harmonic filter behaviour in a twelve-pulse LCI drive system under power converter faults

被引:0
|
作者
Alcaso, AN [1 ]
Cardoso, AJM [1 ]
机构
[1] ESTG IT, Polytech Inst Guarda, P-6300559 Guarda, Portugal
关键词
D O I
10.1109/PESC.2005.1582044
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a study concerning the behaviour of harmonic filters in a twelve-pulse LCI drive system after the occurrence of an open-switch fault in the line-side power converters. The main objective of this study is to analyse the operation of the filter subjected to the new harmonics developed by the drive under faulty operating conditions, with and without the introduction of compensating modes of operation, developed with the goal of introducing fault-tolerance to these high-power adjustable speed motor drives. To validate the study some experimental results are presented for the case of the classical passive filtering. Preliminary results obtained by simulation, are also presented for the case of active filtering.
引用
收藏
页码:2893 / 2897
页数:5
相关论文
共 43 条
  • [21] Real Time Implementation of Multilevel Converter based Shunt Active Power Filter for Harmonic Compensation in Distribution System
    Tandekar, Jitendra
    Ojha, Amit
    Jain, Shailendra
    2016 7TH INDIA INTERNATIONAL CONFERENCE ON POWER ELECTRONICS (IICPE), 2016,
  • [22] Derating of transformers under harmonic currents in urban mass transit traction power supply system
    Zhang M.-R.
    Li N.
    Gong X.-D.
    Tiedao Xuebao/Journal of the China Railway Society, 2011, 33 (12): : 38 - 45
  • [23] Harmonic filtering of high-power 12-pulse rectifier loads with a selective hybrid filter system
    Basic, D
    Ramsden, VS
    Muttik, PK
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2001, 48 (06) : 1118 - 1127
  • [24] Performance Analysis of the Slip Power Recovery Induction Motor Drive System Under Unbalance Supply Voltages
    Ameen, Hilmi Fadhil
    Aula, Fadhil Toufick
    ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2021, 19 (03) : 192 - 202
  • [25] Robust Design Scheme of C-Type Filter Considering Harmonic Dynamic Characteristics of Traction Power Supply System
    Wu, Hexiang
    Zeng, Liyong
    Ren, Qingshuo
    Ai, Lei
    IEEE ACCESS, 2022, 10 : 47782 - 47791
  • [26] Harmonic compensation of a six-pulse current source controlled converter using neural network-based shunt active power filter
    Hamad, Mostafa S.
    Gadoue, Shady M.
    Williams, Barry W.
    IET POWER ELECTRONICS, 2012, 5 (06) : 747 - 754
  • [27] Supply System Based on the 18-pulse Diode Rectifier with Coupled Reactors and Integrated with the Series Active Power Filter
    Mysiak, P.
    Strzelecki, R.
    Tunia, H.
    Zymmer, K.
    2011 7TH INTERNATIONAL CONFERENCE-WORKSHOP COMPATIBILITY AND POWER ELECTRONICS (CPE), 2011, : 442 - 451
  • [28] Finite-state model predictive power control of three-phase bidirectional AC/DC converter under unbalanced grid faults with current harmonic reduction and power compensation
    Jin, Nan
    Guo, Leilei
    Gan, Chun
    Hu, Shiyang
    Dou, Zhifeng
    IET POWER ELECTRONICS, 2018, 11 (02) : 348 - 356
  • [29] An Improved SHE Algorithm and Filter Design Method for High Power Grid-Connected Converter under Unbalanced and Harmonic Distorted Grid
    Cheng, Jingling
    Chen, Dongdong
    Hu, Yaowei
    Chen, Guozhu
    2017 IEEE 26TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2017, : 594 - 599
  • [30] Control of grid-side converter of direct-drive wind power system under unbalanced voltage dips
    Zhu, Lin
    Xu, Dianguo
    Ma, Hongfei
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2007, 22 (SUPPL. 1): : 101 - 106