Radiation dose for pedicle screw insertion -: Fluoroscopic method versus computer-assisted surgery

被引:136
|
作者
Slomczykowski, M
Roberto, M
Schneeberger, P
Ozdoba, C
Vock, P
机构
[1] Univ Bern, Inselspital, Dept Orthopaed, CH-3012 Bern, Switzerland
[2] Univ Bern, Inselspital, Dept Radiooncol, CH-3012 Bern, Switzerland
[3] Univ Bern, Inselspital, Dept Neuroradiol, CH-3012 Bern, Switzerland
[4] Univ Bern, Inselspital, Dept Diagnost Radiol, CH-3012 Bern, Switzerland
[5] Nicholas Copernicus Univ, Dept Orthopaed & Traumatol, Lodz, Poland
关键词
computer-assisted surgery; dose; fluoroscopy; radiation;
D O I
10.1097/00007632-199905150-00009
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Comparison of the radiation dose between the traditional fluoroscopic approach and computed tomography (CT)-based computer-assisted surgery for pedicle screw placement was determined. Objectives. To evaluate the radiation dose delivered by fluoroscopy-controlled pedicle screw placement versus insertion guided by computer. To define the CT computer-assisted protocol, involving lower radiation exposure for the patient, that still provides acceptable image quality. Summary of Background Data. There are no published data describing the dose delivered in CT-based image-guided surgery, and there are few studies in which the;;organ dose and the effective dose delivered during pedicle screw insertion that is performed traditionally with fluoroscopic control are described. Methods. Dose measurements were performed on two types (REMAB and RANDO) of anthropomorphic phantoms. Thermoluminescent dosimeters were used to measure the organ dose. Both phantoms were exposed to the fluoroscopic x-ray beam. The representative intraoperative scenario was determined by observation of 20 consecutive surgical interventions featuring pedicle screw implantation. For the CT dose measurement only, the REMAB phantom was used with two types of CT scanners. Three scanning protocols were evaluated: sequential, spiral optimized, and sequential optimized. Optimization of the scanning protocol included changes of anode current. The CT images were subsequently processed to achieve three-dimensional reconstruction of the lumbar spine for the computer-assisted intervention. Results. Organ and effective doses were higher in any of the CT examinations than in the fluoroscopic procedure. There was a slight difference between doses registered during optimized spiral scanning and doses in the calculated optimized sequential CT protocol. Optimized sequential scanning was associated with an effective dose 40% lower than that in nonoptimized sequential scanning. The small anatomic structures of the spine could be easily recognized on each of the three-dimensional reconstructions, and all of them were suitable for use in computer-assisted surgery. Conclusions. Percutaneous pedicle screw insertion in the lumbar region of the spine, performed using fluoroscopic control, requires a lower radiation dose than do CT scans necessary for computer-assisted surgery. The CT radiation dose can be significantly decreased by optimization of the scanner settings for computer-assisted surgery. The advantages of computer-assisted surgery justify CT scans, when based on correctly chosen indications.
引用
收藏
页码:975 / 982
页数:8
相关论文
共 50 条
  • [1] Radiation dose for pedicle screw insertion -: Fluoroscopic method versus computer-assisted surgery -: Point of view
    Singer, KP
    SPINE, 1999, 24 (10) : 983 - 983
  • [2] Radiation dose of fluoroscopic vs computer-assisted pedicle screw insertion
    Schaeren, S
    Roth, J
    Dick, W
    ORTHOPADE, 2002, 31 (04): : 392 - 396
  • [3] Computer-assisted fluoroscopic targeting system for pedicle screw insertion
    Choi, WW
    Green, BA
    Levi, ADO
    NEUROSURGERY, 2000, 47 (04) : 872 - 878
  • [4] Computer-assisted fluoroscopic targeting system for pedicle screw insertion - Comment
    Traynelis, VC
    NEUROSURGERY, 2000, 47 (04) : 878 - 878
  • [5] Computer-assisted fluoroscopic navigation of pedicle screw insertion - An in vivo feasibility study
    Fu, TS
    Chen, LH
    Wong, CB
    Lai, PL
    Tsai, TT
    Niu, CC
    Chen, WJ
    ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (06): : 730 - 735
  • [6] Radiation dose and fluoroscopy time of conventional versus fluoroscopic computer assisted pedicle screw implantation
    Linhardt, O
    Perlick, L
    Lüring, C
    Stern, U
    Plitz, W
    Grifka, J
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2005, 143 (02): : 175 - 178
  • [7] Computer-Assisted Screw Size and Insertion Trajectory Planning for Pedicle Screw Placement Surgery
    Knez, Dejan
    Likar, Bostjan
    Pernus, Franjo
    Vrtovec, Tomaz
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (06) : 1420 - 1430
  • [8] A novel computer-assisted technique for pedicle screw insertion
    John, P. S.
    James, C.
    Antony, J.
    Tessamma, T.
    Ananda, R.
    Dinesh, K.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2007, 3 (01): : 59 - 63
  • [9] Improved accuracy of computer-assisted cervical pedicle screw insertion
    Kotani, Y
    Abumi, K
    Ito, M
    Minami, A
    JOURNAL OF NEUROSURGERY, 2003, 99 (03) : 257 - 263
  • [10] Computer-assisted orthopaedic surgery (CAOS): From pedicle screw insertion to further applications
    Berlemann, U
    Langlotz, F
    Langlotz, U
    Nolte, LP
    ORTHOPADE, 1997, 26 (05): : 463 - 469