Computer-Assisted Screw Size and Insertion Trajectory Planning for Pedicle Screw Placement Surgery

被引:50
|
作者
Knez, Dejan [1 ]
Likar, Bostjan [1 ]
Pernus, Franjo [1 ]
Vrtovec, Tomaz [1 ]
机构
[1] Univ Ljubljana, Fac Elect Engn, Lab Imaging Technol, SI-1000 Ljubljana, Slovenia
关键词
Pedicle modeling in 3D; pedicle morphometry; pedicle screw placement; preoperative planning; vertebral morphometry; VERTEBRAL BODIES; SPINE SURGERY; SEGMENTATION; REGISTRATION; OSTEOPOROSIS; ACCURACY; STRENGTH; IMAGES; CT;
D O I
10.1109/TMI.2016.2514530
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Pathological conditions that cause instability of the spine are commonly treated by vertebral fixation involving pedicle screw placement surgery. However, existing methods for preoperative planning are based only on geometrical properties of vertebral structures (i.e., shape) without taking into account their structural properties (i.e., appearance). We propose a novel automated method for computer-assisted preoperative planning of the thoracic pedicle screw size and insertion trajectory. The proposed method extracts geometrical properties of vertebral structures by parametric modeling of vertebral bodies and pedicles in three dimensions (3D), and combines them with structural properties, evaluated through underlying image intensities in computed tomography (CT) images while considering the guidelines for pedicle screw design. The method was evaluated on 81 pedicles, obtained from 3D CT images of 11 patients that were appointed for pedicle screw placement surgery. In terms of mean absolute difference (MAD) and corresponding standard deviation (SD), the resulting high modeling accuracy of 0.39 +/- 0.31 mm for 3D vertebral body models and 0.31 +/- 0.25 mm for 3D pedicle models created an adequate anatomical frame for 3D pedicle screw models. When comparing the automatically obtained and manually defined plans for pedicle screw placement, a relatively high agreement was observed, with MAD SD of 0.4 +/- 0.4 mm for the screw diameter, 5.8 +/- 4.2 mm for the screw length, 2.0 +/- 1.4 mm for the pedicle crossing point and 7.6 +/- 5.8 for screw insertion angles. However, a statistically significant increase of 48 +/- 26% in the screw fastening strength in favor of the proposed automated method was observed in 99% of the cases.
引用
收藏
页码:1420 / 1430
页数:11
相关论文
共 50 条
  • [1] ICAPS: An Integrative Computer-Assisted Planning System for pedicle screw insertion
    Voss, G
    Bisler, A
    Bockholt, U
    Müller-Wittig, WK
    Schäffer, A
    [J]. MEDICINE MEETS VIRTUAL REALITY 2001: OUTER SPACE, INNER SPACE, VIRTUAL SPACE, 2001, 81 : 561 - 563
  • [2] COMPUTER-ASSISTED PEDICLE SCREW PLACEMENT PLANNING: TOWARDS CLINICAL PRACTICE
    Knez, Dejan
    Nahle, Imad S.
    Vrtovec, Tomaz
    Parent, Stefan
    Kadoury, Samuel
    [J]. 2018 IEEE 15TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2018), 2018, : 249 - 252
  • [3] A novel computer-assisted technique for pedicle screw insertion
    John, P. S.
    James, C.
    Antony, J.
    Tessamma, T.
    Ananda, R.
    Dinesh, K.
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2007, 3 (01): : 59 - 63
  • [4] Improved accuracy of computer-assisted cervical pedicle screw insertion
    Kotani, Y
    Abumi, K
    Ito, M
    Minami, A
    [J]. JOURNAL OF NEUROSURGERY, 2003, 99 (03) : 257 - 263
  • [5] Computer-assisted fluoroscopic targeting system for pedicle screw insertion
    Choi, WW
    Green, BA
    Levi, ADO
    [J]. NEUROSURGERY, 2000, 47 (04) : 872 - 878
  • [6] Radiation dose for pedicle screw insertion -: Fluoroscopic method versus computer-assisted surgery
    Slomczykowski, M
    Roberto, M
    Schneeberger, P
    Ozdoba, C
    Vock, P
    [J]. SPINE, 1999, 24 (10) : 975 - 982
  • [7] Computer-assisted orthopaedic surgery (CAOS): From pedicle screw insertion to further applications
    Berlemann, U
    Langlotz, F
    Langlotz, U
    Nolte, LP
    [J]. ORTHOPADE, 1997, 26 (05): : 463 - 469
  • [8] Computer-assisted fluoroscopic targeting system for pedicle screw insertion - Comment
    Traynelis, VC
    [J]. NEUROSURGERY, 2000, 47 (04) : 878 - 878
  • [9] Radiation dose of fluoroscopic vs computer-assisted pedicle screw insertion
    Schaeren, S
    Roth, J
    Dick, W
    [J]. ORTHOPADE, 2002, 31 (04): : 392 - 396
  • [10] Computer-assisted thoracic pedicle screw placement -: An in vitro feasibility study
    Kim, KD
    Johnson, JP
    Bloch, O
    Masciopinto, JE
    [J]. SPINE, 2001, 26 (04) : 360 - 364