Online Diagnosis and Localization of High-Resistance Connection in PMSM With Improved Fault Indicator

被引:39
|
作者
Zhang, Jianzhong [1 ]
Hang, Jun [1 ,2 ]
Ding, Shichuan [1 ,3 ]
Cheng, Ming [1 ]
机构
[1] Southeast Univ, Sch Elect Engn, Nanjing 210096, Jiangsu, Peoples R China
[2] Anhui Univ, Coll Elect Engn & Automat, Hefei 230601, Peoples R China
[3] Anhui Univ, Natl Engn Lab Energy Saving Motor & Control Tech, Hefei 230601, Peoples R China
基金
中国国家自然科学基金;
关键词
Fault diagnosis; frequency tracking algorithm; high-resistance connection (HRC); permanent magnet machine; wind energy; INDUCTION-MOTOR DRIVES; TURN FAULTS; MACHINES; UNBALANCE; SYSTEM;
D O I
10.1109/TPEL.2016.2587670
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a method for online diagnosis and localization of high-resistance connection (HRC) in permanent magnet synchronous machine (PMSM) with an improved fault indicator. In the proposed method, the amplitude and initial phase angle of zero-sequence voltage component are both analyzed. Based on the analysis, the fault indicator with angle difference is defined for fault diagnosis and localization. It is shown that not only the HRC can be detected, but also the fault severity can be assessed and the faulty phases can be identified in this method. The simulation and experiment are carried out to verify the theoretical analysis. Both the results show that the proposed method can be effectively applied for online detection and identification of the HRC in the PMSM.
引用
收藏
页码:3585 / 3594
页数:10
相关论文
共 50 条
  • [41] Online Fault Diagnosis, Classification, and Localization in Photovoltaic Systems
    Parsa, Hamid Reza
    Sarvi, Mohammad
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 8
  • [42] IMPROVED HIGH-RESISTANCE METER FOR 3-TERMINAL OBJECTS
    KANDYBKO, AM
    MEASUREMENT TECHNIQUES USSR, 1989, 32 (06): : 578 - 581
  • [43] Numerical Simulation of an Improved Structure for High-Resistance Grate Plates
    Cao, Qun
    Cui, Zheng
    Sun, Qie
    Cheng, Lin
    CLEAN ENERGY FOR CLEAN CITY: CUE 2016 - APPLIED ENERGY SYMPOSIUM AND FORUM: LOW-CARBON CITIES AND URBAN ENERGY SYSTEMS, 2016, 104 : 407 - 412
  • [44] Improved high-resistance meter for three-terminal objects
    Kandybko, A.M.
    Measurement Techniques (English translation of Izmeritel'naya Tekhnika), 1989, 32 (06):
  • [45] IMPROVED ELECTRICAL FILTER PERFORMANCE IN TRAPPING HIGH-RESISTANCE DUST
    Sanaev, Yu. I.
    CHEMICAL AND PETROLEUM ENGINEERING, 2005, 41 (9-10) : 496 - 498
  • [46] HIGH-RESISTANCE NEUTRAL GROUNDING IN INDUSTRIAL SYSTEMS AND THE GROUND FAULT PROTECTION
    Bernardi, Gladston A. F.
    de Carvalho Filho, Jose Maria
    2013 BRAZILIAN POWER ELECTRONICS CONFERENCE (COBEP), 2013, : 1276 - 1282
  • [47] A nondestructive high-resistance fault diagnosis method of XLPE medium voltage cables based on Chirp-TDR
    Yang, Saike
    Li, Tianhui
    Pang, Xianhai
    Gu, Chaomin
    MEASUREMENT, 2024, 235
  • [48] AN ACCURATE ALGORITHM FOR HIGH-RESISTANCE EARTH-FAULT DISTANCE PROTECTION
    ELSAYED, MAH
    FIKRI, M
    ELECTRIC POWER SYSTEMS RESEARCH, 1986, 11 (02) : 95 - 101
  • [49] A novel algorithm for high-resistance earth-fault distance protection
    Ye, P
    Li, KK
    Chen, DS
    David, AK
    1996 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE PROCEEDINGS, 1996, : 475 - 480
  • [50] High-Resistance Connection Detection in Induction Motor Drives Using Signal Injection
    de la Barrera, Pablo M.
    Bossio, Guillermo R.
    Solsona, Jorge A.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (07) : 3563 - 3573