Prostate brachytherapy postimplant dosimetry: A comparison of prostate quadrants

被引:35
|
作者
Sidhu, S [1 ]
Morris, WJ [1 ]
Spadinger, I [1 ]
Keyes, M [1 ]
Hilts, M [1 ]
Harrison, R [1 ]
Otto, K [1 ]
McKenzie, M [1 ]
Agranovich, A [1 ]
机构
[1] BC Canc Agcy, Vancouver, BC V5Z 4E6, Canada
关键词
prostate brachytherapy; postimplant dosimetry; treatment volume;
D O I
10.1016/S0360-3016(01)02672-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate postimplant dosimetry for different regions of the prostate gland in patients treated with transperineal (125)Iodine brachytherapy implants for low- and intermediate-risk prostate cancer. Methods and Materials: Two hundred eighty-four patients treated with permanent interstitial prostate brachytherapy comprised the study population. A nonuniform, urethral-sparing algorithm was used to plan all patients. Prostate contours were outlined on postimplant CT images. Prostate volumes were then divided into four quadrants: anterior-superior quadrant (ASQ), posterior-superior quadrant (PSQ), anterior-inferior quadrant (AIQ), and posterior-inferior quadrant (PIQ). Dose-volume histograms (DVHs) were calculated for the whole prostate and each quadrant. Results: The mean postimplant V-100 +/- 95% confidence (the percent prostate volume encompassed within the isodose surface comprising the prescription dose = 144 Gy) for the ASQ was 78.5 +/- 1.9, which was significantly lower than that of the PSQ, AIQ, and PIQ in which the V-100 +/- 95% confidence values were 94.9 +/- 0.8, 92.6 +/- 1.2, and 98.7 +/- 0.3, respectively. The mean V-100 +/- 95% confidence for the whole prostate was 90.4 +/- 0.8. Mean values for V-150 and D-90 (the minimum dose in Gy received by 90% of the target volume) for the four quadrants and the whole prostate showed similar results. Conclusions: Underdosed areas of the planning target volume (PTV), if present, were largely confined to the ASQ, which received a significantly lower dose, on average, compared to the other three quadrants of the prostate. (C) 2002 Elsevier Science Inc.
引用
收藏
页码:544 / 552
页数:9
相关论文
共 50 条
  • [41] Preimplant dosimetric parameters as predictors of postimplant quality in permanent prostate brachytherapy
    Butler, W
    Merrick, G
    Allen, Z
    MEDICAL PHYSICS, 2003, 30 (06) : 1430 - 1430
  • [42] Partial volume analysis in LDR brachytherapy of prostate cancer- comparision of intraoperative ultrasound planning and postimplant CT dosimetry
    Warszawski, A.
    Baumann, R.
    Wassermann, J.
    Machtens, S.
    Karstens, J. H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S385 - S386
  • [43] Permanent prostate brachytherapy postimplant magnetic resonance imaging dosimetry using positive contrast magnetic resonance imaging markers
    Martin, Geoffrey V.
    Pugh, Thomas J.
    Mahmood, Usama
    Kudchadker, Rajat J.
    Wang, Jihong
    Bruno, Teresa L.
    Bathala, Tharakeswara
    Blanchard, Pierre
    Frank, Steven J.
    BRACHYTHERAPY, 2017, 16 (04) : 761 - 769
  • [44] How does postimplant edema effect the rectal dose in prostate brachytherapy?
    Dicker, AP
    Waterman, FM
    RADIOLOGY, 1999, 213P : 109 - 109
  • [45] Use of sector analysis of I-125 permanent prostate brachytherapy to evaluate and compare pre- and postimplant dosimetry
    Yoosuf, Ahamed Badusha Mohamed
    Workman, Geraldine
    O'Toole, Monica M.
    Straney, Margaret
    Verghis, Rejina
    Napier, Eoin
    Mitchell, Darren M.
    JOURNAL OF CLINICAL ONCOLOGY, 2012, 30 (05)
  • [46] Registration of prostate brachytherapy seeds with prostate anatomy for improved patient dosimetry
    Gong, LX
    Cho, P
    Ben, H
    Pathak, SD
    Haynor, D
    Wallner, K
    Sutlief, S
    Kim, YM
    MEDICAL IMAGING 2002: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2002, 4681 : 567 - 575
  • [47] Influence of Zonal Dosimetry on Prostate Brachytherapy Outcomes
    Hong, C. W.
    Reddy, C. A.
    Wilkinson, D. A.
    Klein, E. A.
    Ciezki, J. P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S427 - S427
  • [48] Optimisation of rectal dosimetry in LDR prostate brachytherapy
    Mehta, S.
    Khaksar, S.
    Perna, C.
    Otter, S.
    Mikropoulos, C.
    Cunningham, M.
    Long, M. L.
    Uribe-Lewis, S.
    Uribe, J. L.
    Langley, S.
    EUROPEAN UROLOGY, 2022, 81 : S1400 - S1400
  • [49] Ultrasonography and fluoroscopic fusion for prostate brachytherapy dosimetry
    Gong, LX
    Cho, PS
    Han, BH
    Wallner, KE
    Sutlief, SG
    Pathak, SD
    Haynor, DR
    Kim, YM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (05): : 1322 - 1330
  • [50] Influence of zonal dosimetry on prostate brachytherapy outcomes
    Hong, Cheng William
    Reddy, Chandana A.
    Wilkinson, D. Allan
    Klein, Eric A.
    Ciezki, Jay P.
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2015, 7 (01) : 17 - 22