Prostate brachytherapy postimplant dosimetry: A comparison of prostate quadrants

被引:35
|
作者
Sidhu, S [1 ]
Morris, WJ [1 ]
Spadinger, I [1 ]
Keyes, M [1 ]
Hilts, M [1 ]
Harrison, R [1 ]
Otto, K [1 ]
McKenzie, M [1 ]
Agranovich, A [1 ]
机构
[1] BC Canc Agcy, Vancouver, BC V5Z 4E6, Canada
关键词
prostate brachytherapy; postimplant dosimetry; treatment volume;
D O I
10.1016/S0360-3016(01)02672-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate postimplant dosimetry for different regions of the prostate gland in patients treated with transperineal (125)Iodine brachytherapy implants for low- and intermediate-risk prostate cancer. Methods and Materials: Two hundred eighty-four patients treated with permanent interstitial prostate brachytherapy comprised the study population. A nonuniform, urethral-sparing algorithm was used to plan all patients. Prostate contours were outlined on postimplant CT images. Prostate volumes were then divided into four quadrants: anterior-superior quadrant (ASQ), posterior-superior quadrant (PSQ), anterior-inferior quadrant (AIQ), and posterior-inferior quadrant (PIQ). Dose-volume histograms (DVHs) were calculated for the whole prostate and each quadrant. Results: The mean postimplant V-100 +/- 95% confidence (the percent prostate volume encompassed within the isodose surface comprising the prescription dose = 144 Gy) for the ASQ was 78.5 +/- 1.9, which was significantly lower than that of the PSQ, AIQ, and PIQ in which the V-100 +/- 95% confidence values were 94.9 +/- 0.8, 92.6 +/- 1.2, and 98.7 +/- 0.3, respectively. The mean V-100 +/- 95% confidence for the whole prostate was 90.4 +/- 0.8. Mean values for V-150 and D-90 (the minimum dose in Gy received by 90% of the target volume) for the four quadrants and the whole prostate showed similar results. Conclusions: Underdosed areas of the planning target volume (PTV), if present, were largely confined to the ASQ, which received a significantly lower dose, on average, compared to the other three quadrants of the prostate. (C) 2002 Elsevier Science Inc.
引用
收藏
页码:544 / 552
页数:9
相关论文
共 50 条
  • [31] Dosimetry comparison between HDR and permanent implant prostate brachytherapy
    Wang, X
    MEDICAL PHYSICS, 2004, 31 (06) : 1881 - 1881
  • [32] Is the V150 a good quality indicator of postimplant dosimetry for I-125 permanent prostate brachytherapy?
    Zarza Moreno, M.
    Carita, L.
    Antunes, T.
    Fortunato, M.
    Rebola, J.
    Roldao, M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S334 - S335
  • [33] Impact of small prostate size on postimplant prostate dosimetry: Analysis of a large community database
    Taira, Al V.
    Merrick, Gregory S.
    Grimm, Peter
    Butler, Wayne M.
    Lief, Jonathan H.
    Morris, Mallory
    Bennett, Abbey
    BRACHYTHERAPY, 2013, 12 (03) : 222 - 227
  • [34] Ultrasound-CT fusion compared with MR-CT fusion for postimplant dosimetry in permanent prostate brachytherapy
    Bowes, David
    Crook, Juanita M.
    Araujo, Cynthia
    Batchelar, Deidre
    BRACHYTHERAPY, 2013, 12 (01) : 38 - 43
  • [35] Clinical observation and modeling of postimplant seed displacement for prostate brachytherapy
    Fu, L
    Liu, H
    Brasacchio, R
    Rubens, D
    Strang, J
    Messing, E
    Yu, Y
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S504 - S505
  • [36] Impact of transrectal ultrasound- and computed tomography-based seed localization on postimplant dosimetry in prostate brachytherapy
    Chew, Meng-Sang
    Xue, Jinyu
    Houser, Chris
    Misic, Vladimir
    Ca, Junsheng
    Cornwell, Thomas
    Handler, Jay
    Yu, Yan
    Gressen, Eric
    BRACHYTHERAPY, 2009, 8 (02) : 255 - 264
  • [37] Importance of the CT/MRI fusion method as a learning tool for CT-based postimplant dosimetry in prostate brachytherapy
    Tanaka, Osamu
    Hayashi, Shinya
    Sakurai, Kota
    Matsuo, Masayuki
    Nakano, Masahiro
    Maeda, Sunaho
    Hoshi, Hiroaki
    Deguchi, Takashi
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 (03) : 303 - 308
  • [38] In vivo dosimetry in brachytherapy of prostate cancer
    Kawczynska, M.
    Bulski, W.
    Czyzew, B.
    Garmol, D.
    Gruszczynska, E.
    Kasprowicz, A.
    Krol, M.
    Kulik, A.
    Lyczek, J.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S465 - S465
  • [39] A Dynamic Dosimetry System for Prostate Brachytherapy
    Kuo, Nathanael
    Dehghan, Ehsan
    Deguet, Anton
    Song, Danny Y.
    Prince, Jerry L.
    Lee, Junghoon
    MEDICAL IMAGING 2013: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2013, 8671
  • [40] T2*-weighted Image/T2-weighted Image Fusion in Postimplant Dosimetry of Prostate Brachytherapy
    Katayama, Norihisa
    Takemoto, Mitsuhiro
    Yoshio, Kotaro
    Katsui, Kuniaki
    Uesugi, Tatsuya
    Nasu, Yasutomo
    Matsushita, Toshi
    Kaji, Mitsumasa
    Kumon, Hiromi
    Kanazawa, Susumu
    JOURNAL OF RADIATION RESEARCH, 2011, 52 (05) : 680 - 684