Behaviour of concrete filled steel tubular (CFST) short columns externally reinforced using CFRP strips composite

被引:65
|
作者
Prabhu, G. Ganesh [1 ]
Sundarraja, M. C. [2 ]
机构
[1] Sethu Inst Technol, Dept Civil Engn, Virudunagar 626115, Tamil Nadu, India
[2] Thiagarajar Coll Engn, Dept Civil Engn, Thiruparankundram, Tamil Nadu, India
关键词
CFST members; CFRP fabrics; Strengthening Compression; Externally wrapped; COMPRESSIVE BEHAVIOR; BOND CHARACTERISTICS;
D O I
10.1016/j.conbuildmat.2013.06.038
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper focused on experimentally and analytically investigates the suitability of carbon fibre reinforced polymer (CFRP) strips composites in strengthening of CFST members under compression. The size and height of the columns were 91.5 x 91.5 x 3.6 mm and 600 mm respectively. CFRP fabrics was used as horizontal strips (lateral ties) with several other parameters such as the number of layers, width and spacing of strips.-Among the 21 columns, eighteen columns were externally strengthened by CFRP strips having a constant width of 50 mm with the spacing of 30 mm and 40 mm, and the remaining three columns were reference column. Experimental results were revealed that external wrapping of CFRP strips provides restraint against the lateral deformation effectively and delays the local buckling of steel tube. Axial deformation control and load bearing capacity of the confined columns increases as the number of layers increases in addition to that increases in the load bearing capacity mainly depends upon the proper spacing between the CFRP strips. Analytical model was proposed herein for predicting the load bearing capacity of CFRP confined CFST columns. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1362 / 1371
页数:10
相关论文
共 50 条
  • [11] Research on I steel reinforced concrete-filled GFRP tubular short columns
    Xie, Wentao
    Chen, Yu
    Han, Shaohua
    Zhou, Wenbo
    He, Kang
    THIN-WALLED STRUCTURES, 2017, 120 : 282 - 296
  • [12] Behaviour of FRP-strengthened concrete-filled steel tubular composite columns
    College of Civil Engineering, Fuzhou University, Fujian, Fuzhou 350108, China
    不详
    Harbin Gongye Daxue Xuebao, 1600, SUPPL. 2 (18-21):
  • [13] Structural behaviour of short steel-concrete composite spun tubular columns
    Song, YL
    Chen, JF
    MAGAZINE OF CONCRETE RESEARCH, 2000, 52 (06) : 411 - 418
  • [14] Tests on fiber reinforced concrete filled steel tubular columns
    Gopal, SR
    Manoharan, PD
    STEEL AND COMPOSITE STRUCTURES, 2004, 4 (01): : 37 - 48
  • [15] Constitutive relation of concrete of concrete-filled CFRP-steel tubular short columns with axial compression
    Gu, Wei
    Li, Hong-Nan
    Zhang, Mei-Na
    Dalian Ligong Daxue Xuebao/Journal of Dalian University of Technology, 2011, 51 (04): : 545 - 548
  • [16] Creep performance of concrete-filled steel tubular (CFST) columns and applications to a CFST arch bridge
    Yang, Meng-Gang
    Cai, C. S.
    Chen, Yong
    STEEL AND COMPOSITE STRUCTURES, 2015, 19 (01): : 111 - 129
  • [17] Numerical Response of Concrete-Filled Steel Tubular (CFST) Columns Externally Strengthened with FRP Composites Subjected to Cyclic Loading
    Mansour, Walid
    Osama, Bothaina
    Li, Weiwen
    Wang, Peng
    Sobuz, Md. Habibur Rahman
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2024, 18 (01)
  • [18] An experimental behaviour of concrete-filled steel tubular columns
    Zeghiche, J
    Chaoui, K
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2005, 61 (01) : 53 - 66
  • [19] Behaviour of concrete filled steel tubular columns under fire
    查晓雄
    钟善桐
    Journal of Harbin Institute of Technology, 2002, (03) : 292 - 296
  • [20] Composite hollow steel tubular columns filled using high strength concrete
    Gibbons, C
    Scott, D