Numerical Response of Concrete-Filled Steel Tubular (CFST) Columns Externally Strengthened with FRP Composites Subjected to Cyclic Loading

被引:0
|
作者
Mansour, Walid [1 ,2 ]
Osama, Bothaina [3 ]
Li, Weiwen [1 ]
Wang, Peng [1 ,3 ]
Sobuz, Md. Habibur Rahman [4 ]
机构
[1] Shenzhen Univ, Guangdong Prov Key Lab Durabil Marine Civil Engn, Shenzhen 518060, Peoples R China
[2] Kafrelsheikh Univ, Fac Engn, Civil Engn Dept, Kafrelsheikh, Egypt
[3] Hong Kong Univ Sci & Technol, Dept Civil & Environm Engn, Hong Kong, Peoples R China
[4] Khulna Univ Engn & Technol, Dept Bldg Engn & Construct Management, Khulna 9203, Bangladesh
关键词
Concrete-filled steel tubular (CFST) columns; Cyclic loading; Finite element model; Fiber-reinforced polymers (FRPs); Absorbed energy; Stiffness; Viscous damping; FIBER-REINFORCED CONCRETE; SEISMIC BEHAVIOR; STUB COLUMNS; CONFINED CONCRETE; PERFORMANCE; STRESS; STRAIN; DUCTILITY; DESIGN; MODEL;
D O I
10.1186/s40069-024-00716-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The ultimate load-carrying capacity of concrete-filled steel tubular (CFST) columns exposed to monotonic loadings can be greatly increased by strengthening those columns, and the occurrence of the steel tube's outward buckling can be postponed. The current research aims to study the possibility of improving the structural characteristics of CFST columns exposed to cyclic loadings in terms of lateral load capacity and absorbed energy by strengthening them with different patterns of fiber-reinforced polymer (FRP) sheets. The ABAQUS software was used to create a three-dimensional (3D) non-linear finite element model (FEM) to simulate the behavior of FRP-strengthened CFST columns exposed to monotonic and cyclic loadings. After ascertaining the accuracy of the proposed model's results in successfully predicting failure patterns and lateral loads compared to the experimental results of tested specimens available in the literature, the model was used to create a parametric study. The parametric study focused on the impacts of the thickness, location, and length of the strengthening sheets on the failure pattern, lateral load-carrying capacity, stiffness, cumulative energy, absorbed energy, and viscous damping factor of the CFST columns exposed to cyclic loadings. The results revealed that the un-strengthened specimen displayed a maximum lateral load of 185 kN and a viscous damping factor of 45.2% at a lateral drift of 5.7%. On the other hand, strengthening the CFST column using five layers of FRP sheets exhibited the highest lateral load of all investigated columns (50% more than the un-strengthened specimen). Additionally, at a lateral drift of 5.7%, the decrease in viscous damping factor of CFST specimens due to strengthening using 1, 2, 3, 4, and 5 layers of FRP sheets with respect to the control specimen was 7.9%, 14.9%, 20.8%, 27.7%, and 30.3%, respectively.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Behaviour of FRP-strengthened concrete-filled steel tubular composite columns
    College of Civil Engineering, Fuzhou University, Fujian, Fuzhou 350108, China
    不详
    Harbin Gongye Daxue Xuebao, 1600, SUPPL. 2 (18-21):
  • [2] Cyclic lateral response of FRP-confined circular concrete-filled steel tubular columns
    Yu, T.
    Hu, Y. M.
    Teng, J. G.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 124 : 12 - 22
  • [3] Behaviour of concrete-filled steel columns subjected to lateral cyclic loading
    Gajalakshmi, P.
    Helena, H. Jane
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 75 : 55 - 63
  • [4] Analysis of partially concrete-filled steel tubular columns subjected to cyclic loadings
    Department of Civil and Environmental Engineering, Tokyo Denki University, Hatoyama, Hiki, Saitama 350-0394, Japan
    CMES Comput. Model. Eng. Sci., 2006, 3 (121-130):
  • [5] Analysis of partially concrete-filled steel tubular columns subjected to cyclic loadings
    Ishizawa, T
    Iura, M
    CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2006, 11 (03): : 121 - 130
  • [6] EXPERIMENTAL AND NUMERICAL MODELLING OF COMPOSITE CRISSCROSS CONCRETE-FILLED STEEL TUBULAR COLUMNS SUBJECTED TO EARTHQUAKE LOADING
    Yang, T. Y.
    Tung, Dorian P.
    Xu, Chengxiang
    PROCEEDINGS OF THE TWELFTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOLS I AND II, 2012, : 1164 - 1169
  • [7] Axial loading behavior of CFRP strengthened concrete-filled steel tubular stub columns
    Tao, Zhong
    Han, Lin-Hai
    Zhuang, Jin-Ping
    ADVANCES IN STRUCTURAL ENGINEERING, 2007, 10 (01) : 37 - 46
  • [8] ANALYSIS OF FRP-STRENGTHENED CONCRETE-FILLED STEEL TUBULAR COLUMNS UNDER AXIAL COMPRESSION
    Wang, Zhi-Bin
    Tao, Zhong
    Uy, Brian
    Han, Lin-Hai
    PROCEEDINGS OF THE FIRST INTERNATIONAL POSTGRADUATE CONFERENCE ON INFRASTRUCTURE AND ENVIRONMENT, 2009, : 485 - 492
  • [9] Behaviour of recycled aggregate concrete-filled stainless steel tubular columns subjected to lateral monotonic and cyclic loading
    Xu, Chuan -Yang
    Han, Lin-Hai
    Hou, Chao
    ENGINEERING STRUCTURES, 2023, 293
  • [10] Performance evaluation and FRP strengthening of concrete-filled steel tubular columns subjected to vehicle impact
    Hu, Bo
    Wang, Hai-Bo
    ADVANCES IN STRUCTURAL ENGINEERING, 2024, 27 (08) : 1377 - 1396