3D Stent Recovery from One X-Ray Projection

被引:0
|
作者
Demirci, Stefanie [1 ]
Bigdelou, Ali [1 ]
Wang, Lejing [1 ]
Wachinger, Christian [1 ]
Baust, Maximilian [1 ]
Tibrewal, Radhika [1 ]
Ghotbi, Reza [2 ]
Eckstein, Hans-Henning [3 ]
Navab, Nassir [1 ]
机构
[1] Tech Univ Munich, Comp Aided Med Procedures, D-8000 Munich, Germany
[2] Klinikum Munchen Pasing, Vasc Surg, Munich, Germany
[3] Klinikum Rechts Der Isar, Dept Vasc Surg, Munich, Germany
关键词
REGISTRATION;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In the current clinical workflow of endovascular abdominal aortic repairs (EVAR) a stent graft is inserted into the aneurysmatic aorta under 2D angiographic imaging. Due to the missing depth information in the X-ray visualization, it is highly difficult in particular for junior physicians to place the stent graft in the preoperatively defined position within the aorta. Therefore, advanced 3D visualization of stent grafts is highly required. In this paper, we present a novel algorithm to automatically match a 3D model of the stent graft to an intraoperative 2D image showing the device. By automatic preprocessing and a global-to-local registration approach, we are able to abandon user interaction and still meet the desired robustness. The complexity of our registration scheme is reduced by a semi-simultaneous optimization strategy incorporating constraints that correspond to the geometric model of the stent graft. Via experiments on synthetic, phantom, and real interventional data, we are able to show that the presented method matches the stent graft model to the 2D image data with good accuracy.
引用
收藏
页码:178 / +
页数:2
相关论文
共 50 条
  • [31] X-ray lithography for 3D microfluidic applications
    Romanato, F
    Tormen, M
    Businaro, L
    Vaccari, L
    Stomeo, T
    Passaseo, A
    Di Fabrizio, E
    MICROELECTRONIC ENGINEERING, 2004, 73-4 : 870 - 875
  • [32] Quantification for 3D micro X-ray fluorescence
    Mantouvalou, Ioanna
    Malzer, Wolfgang
    Kanngiesser, Birgit
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 77 : 9 - 18
  • [33] 3D Stereo Algorithm for X-ray Units
    Miroshnychenko, S., I
    Volkov, E. V.
    2014 IEEE 34TH INTERNATIONAL CONFERENCE ON ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2014, : 316 - 318
  • [34] Calibration of X-ray projections in 3D reconstruction
    Wang, P
    Mou, XQ
    Qin, ZY
    Cai, YL
    VISUALIZATION AND OPTIMIZATION TECHNIQUES, 2001, 4553 : 44 - 49
  • [35] Factorization method for the 3D X-ray transform
    Defrise, M.
    Inverse Problems, 1995, 11 (05):
  • [36] MICROFOCUS X-RAY SOURCES FOR 3D MICROTOMOGRAPHY
    FLYNN, MJ
    HAMES, SM
    REIMANN, DA
    WILDERMAN, SJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3): : 312 - 315
  • [37] VISUALISATION OF DYNAMIC ADSORPTION BY 2D X-RAY RADIOGRAPHY AND 3D X-RAY μ-TOMOGRAPHY
    Almazan-Almazan, M. C.
    Leonard, A.
    Toye, D.
    Lodewyckx, P.
    Pirard, J. P.
    Lopez-Garzon, F. J.
    Blacher, S.
    CHARACTERISATION OF POROUS SOLIDS VIII, 2009, (318): : 233 - 239
  • [38] X-ray imaging of laser produced plasmas by a compound 3D x-ray lens
    Garanin, R. V.
    Pavlov, G. A.
    Suslov, N. A.
    Treushnikov, V. M.
    Treushnikov, V. V.
    Zhidkov, N. V.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [39] 3D dynamic measurement of coronary arteries from X-ray images
    Department of Electronic and Communication Engineering, North China Electric Power University, Baoding 071003, Hebei, China
    不详
    Iran. J. Electr. Comput. Eng., 2007, 2 (141-147):
  • [40] Bayesian 3D X-ray reconstruction from incomplete noisy data
    Vengrinovich, V
    Denkevich, Y
    Tillack, GR
    MAXIMUM ENTROPY AND BAYESIAN METHODS, 1999, 105 : 73 - 81