Comparison of Real Time Two-Dimensional with Live/Real Time Three-Dimensional Transesophageal Echocardiography in the Evaluation of Mitral Valve Prolapse and Chordae Rupture

被引:48
|
作者
Manda, Jayaprakash
Kesanolla, Saritha Kumari
Hsuing, Ming Chon [2 ]
Nanda, Navin C. [1 ]
Abo-Salem, Elsayed
Dutta, Rajarshi
Laney, Charles Allen
Wei, Jeng [2 ]
Chang, Chung-Yi [2 ]
Tsai, Shen-Kou
Hansalia, Sachin
Yin, Wei-Hsian [2 ]
Young, Mason S. [2 ]
机构
[1] Univ Alabama, Heart Stn SWB S102, Div Cardiovasc Dis, Birmingham, AL 35249 USA
[2] Cheng Hsin Med Ctr, Div Cardiovasc Dis, Taipei, Taiwan
关键词
mitral valve prolapse; mitral valve chordae rupture; three-dimensional transesophageal echocardiography; two-dimensional transesophageal echocardiography;
D O I
10.1111/j.1540-8175.2008.00832.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We compared live/real time three-dimensional transesophageal echocardiography (3D TEE) with real time two-dimensional transesophageal echocardiography (2D TEE) in the assessment of individual mitral valve (MV) segment/scallop prolapse and associated chordae rupture in 18 adult patients with a flail MV undergoing surgery for mitral regurgitation. 2D TEE was able to diagnose the prolapsing segment/scallop and associated chordae rupture correctly in only 9 of 18 patients when compared to surgery. In three of these, 2D TEE diagnosed an additional segment/scallop not confirmed at surgery. In the remaining nine patients, surgical findings were missed by 2D TEE. On the other hand with 3D TEE, the prolapsed segment/scallop and associated ruptured chords correlated exactly with the surgical findings in the operating room in 16 of 18 patients. The exceptions were two patients. In one, 3D TEE diagnosed prolapse and ruptured chordae of the A3 segment and P3 scallop, while the surgical finding was chordae rupture of the A3 segment but only prolapse without chordae rupture of the P3 scallop. In the other patient, 3D TEE diagnosed prolapse and chordae rupture of P1 scallop and prolapse without chordae rupture of the A1 and A2 segments, while at surgery chordae rupture involved A1, A2, and P1. This preliminary study demonstrates the superiority of 3D TEE over 2D TEE in the evaluation of individual MV segment/scallop prolapse and associated ruptured chordae. (ECHOCARDIOGRAPHY, Volume 25, November 2008)
引用
收藏
页码:1131 / 1137
页数:7
相关论文
共 50 条
  • [41] Incremental Value of Live/Real Time Three-Dimensional Transesophageal Echocardiography over the Two-Dimensional Modality in the Assessment of Cardiac Lymphoma
    Thind, Munveer
    Hsiung, Ming C.
    Gok, Gulay
    Elsayed, Mahmoud
    Joson, Marisa
    Nanda, Navin C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (04): : 671 - 676
  • [42] Incremental Value of Live/Real Time Three-Dimensional over Two-Dimensional Transesophageal Echocardiography in the Assessment of Atrial Septal Pouch
    Elsayed, Mahmoud
    Hsiung, Ming C.
    Meggo-Quiroz, L. David
    Elguindy, Mostafa
    Uygur, Begum
    Tandon, Rohit
    Guvenc, Tolga
    Keser, Nurgul
    Vural, Mustafa G.
    Bulur, Serkan
    Chahwala, Jugal R.
    Abtahi, Firoozeh
    Nanda, Navin C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (12): : 1858 - 1867
  • [43] Clinical utility of new real time three-dimensional transthoracic echocardiography in assessment of mitral valve prolapse
    Hirata, Kumiko
    Pulerwitz, Todd
    Sciacca, Robert
    Otsuka, Ryo
    Oe, Yukiko
    Fujikura, Kana
    Oe, Hiroki
    Hozumi, Takeshi
    Yoshiyama, Minoru
    Yoshikawa, Junichi
    Di Tullio, Marco
    Homma, Shunichi
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2008, 25 (05): : 482 - 488
  • [44] Live three-dimensional transesophageal echocardiography in mitral valve surgery
    MA NingLI ZhianMENG Xu and YANG Ya Department of Ultrasonography Department of Cardiac Surgery Beijing Anzhen HospitalCapital Medical UniversityBeijing China
    中华医学杂志(英文版), 2008, (20) : 2037 - 2041
  • [45] Live three-dimensional transesophageal echocardiography in mitral valve surgery
    Ma Ning
    Li Zhi-An
    Meng Xu
    Yang Ya
    CHINESE MEDICAL JOURNAL, 2008, 121 (20) : 2037 - 2041
  • [46] Real-Time Three-Dimensional Transesophageal Echocardiography for Assessment of Mitral Valve Functional Anatomy in Patients With Prolapse-Related Regurgitation
    La Canna, Giovanni
    Arendar, Iryna
    Maisano, Francesco
    Monaco, Fabrizio
    Collu, Egidio
    Benussi, Stefano
    De Bonis, Michele
    Castiglioni, Alessandro
    Alfieri, Ottavio
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (09): : 1365 - 1374
  • [47] Implementation of Real-Time Three-Dimensional Transesophageal Echocardiography for Mitral Balloon Valvuloplasty
    Eng, Marvin H.
    Salcedo, Ernesto E.
    Kim, Michael
    Quaife, Robert A.
    Carroll, John D.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (06) : 994 - 998
  • [48] Real Time Three-Dimensional Transesophageal Echocardiography in Partial Posteromedial Papillary Muscle Rupture
    Havins, Jeremiah
    Lick, Scott
    Boor, Paul
    Arora, Harvinder
    Ahmad, Masood
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2013, 30 (06): : E179 - E181
  • [49] Anterior mitral leaflet perforation identified by real time three-dimensional transesophageal echocardiography
    Cheng, Hsiao-Liang
    Cheng, Ya-Jung
    Lai, Chia-Hsin
    CARDIOLOGY JOURNAL, 2012, 19 (01) : 89 - 91
  • [50] Usefulness of Live/Real Time Three-Dimensional Transesophageal Echocardiography in the Assessment of Severe Mitral Annuloplasty Ring Dehiscence
    Piatkowski, Radoslaw
    Janusz, Kochanowski
    Scislo, Piotr
    Opolski, Grzegorz
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (03): : E80 - E81