Comparison of Real Time Two-Dimensional with Live/Real Time Three-Dimensional Transesophageal Echocardiography in the Evaluation of Mitral Valve Prolapse and Chordae Rupture

被引:48
|
作者
Manda, Jayaprakash
Kesanolla, Saritha Kumari
Hsuing, Ming Chon [2 ]
Nanda, Navin C. [1 ]
Abo-Salem, Elsayed
Dutta, Rajarshi
Laney, Charles Allen
Wei, Jeng [2 ]
Chang, Chung-Yi [2 ]
Tsai, Shen-Kou
Hansalia, Sachin
Yin, Wei-Hsian [2 ]
Young, Mason S. [2 ]
机构
[1] Univ Alabama, Heart Stn SWB S102, Div Cardiovasc Dis, Birmingham, AL 35249 USA
[2] Cheng Hsin Med Ctr, Div Cardiovasc Dis, Taipei, Taiwan
关键词
mitral valve prolapse; mitral valve chordae rupture; three-dimensional transesophageal echocardiography; two-dimensional transesophageal echocardiography;
D O I
10.1111/j.1540-8175.2008.00832.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We compared live/real time three-dimensional transesophageal echocardiography (3D TEE) with real time two-dimensional transesophageal echocardiography (2D TEE) in the assessment of individual mitral valve (MV) segment/scallop prolapse and associated chordae rupture in 18 adult patients with a flail MV undergoing surgery for mitral regurgitation. 2D TEE was able to diagnose the prolapsing segment/scallop and associated chordae rupture correctly in only 9 of 18 patients when compared to surgery. In three of these, 2D TEE diagnosed an additional segment/scallop not confirmed at surgery. In the remaining nine patients, surgical findings were missed by 2D TEE. On the other hand with 3D TEE, the prolapsed segment/scallop and associated ruptured chords correlated exactly with the surgical findings in the operating room in 16 of 18 patients. The exceptions were two patients. In one, 3D TEE diagnosed prolapse and ruptured chordae of the A3 segment and P3 scallop, while the surgical finding was chordae rupture of the A3 segment but only prolapse without chordae rupture of the P3 scallop. In the other patient, 3D TEE diagnosed prolapse and chordae rupture of P1 scallop and prolapse without chordae rupture of the A1 and A2 segments, while at surgery chordae rupture involved A1, A2, and P1. This preliminary study demonstrates the superiority of 3D TEE over 2D TEE in the evaluation of individual MV segment/scallop prolapse and associated ruptured chordae. (ECHOCARDIOGRAPHY, Volume 25, November 2008)
引用
收藏
页码:1131 / 1137
页数:7
相关论文
共 50 条
  • [31] Real Time Three-Dimensional Transesophageal Echocardiography for Guiding Percutaneous Mitral Valvuloplasty
    Dobarro, David
    Carmen Gomez-Rubin, Maria
    Lopez-Fernandez, Teresa
    Galeote, Guillermo
    Sanchez-Recalde, Angel
    Martin-Reyes, Roberto
    Moreno-Yanguela, Mar
    Moreno, Raul
    Lopez-Sendon, Jose
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (06): : 746 - 748
  • [32] EVALUATION THE ALTERATION OF MITRAL VALVE STRUCTURES IN FUNCTIONAL MITRAL REGURGITATION USING REAL-TIME THREE-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    Bai, Wenjuan
    Li, Hui
    Rao, Li
    HEART, 2012, 98 : E172 - E173
  • [33] Evaluation the alteration of mitral valve structures in functional mitral regurgitation using real-time three-dimensional transesophageal echocardiography
    Bai, W.
    Tang, H.
    Rao, L.
    EUROPEAN HEART JOURNAL, 2012, 33 : 103 - 103
  • [34] Effect of Performing Real Time Three-Dimensional Transesophageal Echocardiography in Addition to Two-Dimensional Transesophageal Echocardiography on Operator Diagnostic Confidence
    Willens, Howard J.
    Hendel, Robert C.
    Qin, Jian Xin
    Ma, Carol
    Keith, Karen
    Torres, Silvia
    Grossman, Jay R.
    Moscucci, Mauro
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2011, 28 (02): : 235 - 242
  • [35] Thrombosis of a bileaflet prosthetic mitral valve: a real-time three-dimensional transesophageal echocardiography perspective
    Biswajit Paul
    Anil Minocha
    The International Journal of Cardiovascular Imaging, 2010, 26 : 367 - 368
  • [36] Three-dimensional versus two-dimensional transesophageal echocardiography in mitral valve repair
    Garcia-Orta, Rocio
    Moreno, Eduardo
    Vidal, Matilde
    Ruiz-Lopez, Fuensanta
    Oyonarte, Jose M.
    Lara, Juan
    Moreno, Teodoro
    Garcia-Fernandezd, Miguel A.
    Azpitarte, Jose
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (01) : 4 - 12
  • [37] Impact of real-time three-dimensional transesophageal echocardiography on procedural success for mitral valve repair
    Mori M.
    Yoshimuta T.
    Ohira M.
    Yagi M.
    Sakata K.
    Konno T.
    Kawashiri M.-A.
    Tomita S.
    Watanabe G.
    Iino K.
    Takemura H.
    Yamagishi M.
    Hayashi K.
    Journal of Echocardiography, 2015, 13 (3) : 100 - 106
  • [38] Thrombosis of a bileaflet prosthetic mitral valve: a real-time three-dimensional transesophageal echocardiography perspective
    Paul, Biswajit
    Minocha, Anil
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (04): : 367 - 368
  • [39] Mitral Valve Libman-Sacks Endocarditis Visualized by Real Time Three-Dimensional Transesophageal Echocardiography
    Shroff, Hersh
    Benenstein, Ricardo
    Freedberg, Robin
    Mehl, Sydney
    Saric, Muhamed
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (04): : E100 - E101
  • [40] The Advantages of Live/Real Time Three-Dimensional Transesophageal Echocardiography in the Assessment of Tricuspid Valve Infective Endocarditis
    Sungur, Aylin
    Hsiung, Ming C.
    Quiroz, Luis D. Meggo
    Oez, Tugba Kemaloglu
    Asaad, Ayman Haj
    Joshi, Deepak
    Doenmez, Cevdet
    Guevenc, Tolga S.
    Nanda, Navin C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (10): : 1293 - 1309