Composite action in concrete filled tubes

被引:262
|
作者
Roeder, CW [1 ]
Cameron, B
Brown, CB
机构
[1] Univ Washington, Seattle, WA 98195 USA
[2] Skilling Ward Magnusson & Barkshire, Seattle, WA 98101 USA
[3] Oregon State Univ, Corvallis, OR 97331 USA
来源
JOURNAL OF STRUCTURAL ENGINEERING-ASCE | 1999年 / 125卷 / 05期
关键词
D O I
10.1061/(ASCE)0733-9445(1999)125:5(477)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper studies composite action in concrete filled tubes (CFT) that have dimensions and proportions like those used in U.S. practice. CFT applications in buildings and the importance of bond stress and interface conditions to behavior are noted, past research is summarized, and the combined results are analyzed. An experimental study is described and evaluated. It is shown that shrinkage can be very detrimental to bond stress capacity, and the importance of shrinkage depends upon the characteristics of the concrete, the diameter of the tube, and the surface condition at the inside of the tube. The bond capacity is smaller with large diameter tubes and large d/t ratios. The bond capacity is interrelated with slip at the steel concrete interface. An exponential distribution of bond stress is expected prior to slip, and a more uniform distribution occurs after slip. An equation that estimates the bond stress capacity is developed, and this leads to design recommendations at different performance levels.
引用
收藏
页码:477 / 484
页数:8
相关论文
共 50 条
  • [31] Composite Flexural Behavior of Full-Scale Concrete-Filled Tubes without Axial Loads
    Probst, Aaron D.
    Kang, Thomas H-K
    Ramseyer, Chris
    Kim, Uksun
    JOURNAL OF STRUCTURAL ENGINEERING, 2010, 136 (11) : 1401 - 1412
  • [32] Ductility Characteristics of Partially Restrained Beam-to-Column Composite Connections in Concrete Filled Square Tubes
    Park, Suhee
    Choi, Sungmo
    Park, Youngwook
    Kim, Yosuk
    Kim, Jinho
    ADVANCES IN STRUCTURAL ENGINEERING, 2008, 11 (05) : 565 - 575
  • [33] Axial performance of GGBFS concrete filled steel tubes
    Ahmad, Subhan
    Kumar, Ajay
    Kumar, Kamal
    STRUCTURES, 2020, 23 : 539 - 550
  • [34] Foundation connections for circular concrete-filled tubes
    Lehman, Dawn E.
    Roeder, Charles W.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 78 : 212 - 225
  • [35] Moment capacity of concrete filled double skin tubes
    Zhao, X. L.
    Choi, A.
    TUBULAR STRUCTURES XIII, 2010, : 583 - 590
  • [36] Concrete filled double skin circular tubes: a review
    Essopjee, Yoosuf
    Dundu, Morgan
    CONSTRUCTION MATERIALS AND STRUCTURES, 2014, : 1068 - 1073
  • [37] Splicing of precast concrete-filled FRP tubes
    Zhu, Zhenyu
    Ahmad, Iftekhar
    Mirmiran, Amir
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2006, 10 (04) : 345 - 356
  • [38] Analysis of local stability of the rectangular tubes filled with concrete
    Kanishchev, R. A.
    MAGAZINE OF CIVIL ENGINEERING, 2016, 64 (04): : 59 - 68
  • [39] Axially loaded concrete-filled steel tubes
    Srinivasan, CN
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1999, 125 (10): : 1202 - 1206
  • [40] Bond behavior in concrete-filled steel tubes
    Tao, Zhong
    Song, Tian-Yi
    Uy, Brian
    Han, Lin-Hai
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 120 : 81 - 93