This paper studies composite action in concrete filled tubes (CFT) that have dimensions and proportions like those used in U.S. practice. CFT applications in buildings and the importance of bond stress and interface conditions to behavior are noted, past research is summarized, and the combined results are analyzed. An experimental study is described and evaluated. It is shown that shrinkage can be very detrimental to bond stress capacity, and the importance of shrinkage depends upon the characteristics of the concrete, the diameter of the tube, and the surface condition at the inside of the tube. The bond capacity is smaller with large diameter tubes and large d/t ratios. The bond capacity is interrelated with slip at the steel concrete interface. An exponential distribution of bond stress is expected prior to slip, and a more uniform distribution occurs after slip. An equation that estimates the bond stress capacity is developed, and this leads to design recommendations at different performance levels.
引用
收藏
页码:477 / 484
页数:8
相关论文
共 50 条
  • [21] Concrete-filled FRP tubes tested
    不详
    CIVIL ENGINEERING, 2000, 70 (03): : 28 - 28
  • [22] Improved Composite Effect of Square Concrete-Filled Steel Tubes with Diagonal Binding Ribs
    Zhou, Zheng
    Gan, Dan
    Zhou, Xuhong
    JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (10)
  • [23] Performance of composite frame consisting of steel beams and concrete filled tubes under fire loading
    Shariati, Mahdi
    Grayeli, Mohammad
    Shariati, Ali
    Naghipour, Morteza
    STEEL AND COMPOSITE STRUCTURES, 2020, 36 (05): : 587 - 602
  • [24] Seismic performance of precast composite shear walls reinforced by concrete-filled steel tubes
    Wu, Liwei
    Tian, Ying
    Su, Youpo
    Chen, Haibin
    ENGINEERING STRUCTURES, 2018, 162 : 72 - 83
  • [25] Modeling of prestressed concrete-filled circular composite tubes subjected to bending and axial loads
    Mandal, S
    Fam, A
    JOURNAL OF STRUCTURAL ENGINEERING, 2006, 132 (03) : 449 - 459
  • [26] Behavior of square hollow steel tubes and steel tubes filled with concrete
    Guo, Lanhui
    Zhang, Sumei
    Kim, What-Jung
    Ranzi, Gianluca
    THIN-WALLED STRUCTURES, 2007, 45 (12) : 961 - 973
  • [27] Experimental Research on Concrete-Filled GFRP Tubes and GFRP-Steel Composite Tubes under Axial Compressive Load
    Wang, Xiaolu
    Zha, Xiaoxiong
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 2052 - 2055
  • [28] Comparative structural performance of composite filled tubes
    Padmaja, M.
    Murty, V. V. V. S.
    Rao, N. V. Ramana
    INTERNATIONAL JOURNAL FOR COMPUTATIONAL METHODS IN ENGINEERING SCIENCE & MECHANICS, 2019, 20 (06): : 477 - 486
  • [29] Composite action of concrete-filled double circular steel tubular stub columns
    Wang, Liping
    Cao, Xing-xing
    Ding, Fa-xing
    Luo, Liang
    Sun, Yi
    Liu, Xue-mei
    Su, Hui-lin
    STEEL AND COMPOSITE STRUCTURES, 2018, 29 (01): : 77 - 90
  • [30] Composite action of hollow concrete-filled circular steel tubular stub columns
    Fu, Qiang
    Ding, Fa-xing
    Zhang, Tao
    Wang, Liping
    Fang, Chang-jing
    STEEL AND COMPOSITE STRUCTURES, 2018, 26 (06): : 693 - 703