Patient-specific mean pressure drop in the systemic arterial tree, a comparison between 1-D and 3-D models

被引:35
|
作者
Reymond, Philippe [1 ]
Perren, Fabienne [2 ]
Lazeyras, Francois [3 ]
Stergiopulos, Nikos
机构
[1] Ecole Polytech Fed Lausanne, Lab Hemodynam & Cardiovasc Technol, EPFL STI IBI2 LHTC, CH-1015 Lausanne, Switzerland
[2] Univ Hosp & Med Fac Geneva, Dept Clin Neurosci, Neurosonol Unit, Geneva, Switzerland
[3] Univ Hosp & Med Fac Geneva, Dept Radiol, Geneva, Switzerland
关键词
Cerebral circulation; CFD; Wave propagation; MRA; Non-Newtonian blood; PULSE-WAVE PROPAGATION; ONE-DIMENSIONAL MODEL; BLOOD-FLOW; COMPUTER-SIMULATION; MATHEMATICAL-MODEL; VALIDATION; WILLIS; CIRCLE; CIRCULATION; NETWORKS;
D O I
10.1016/j.jbiomech.2012.07.020
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
One-dimensional models of the systemic arterial tree are useful tools for studying wave propagation phenomena, however, their formulation for frictional losses is approximate and often based on solutions for developed flow in straight non-tapered arterial segments. Thus, losses due to bifurcations, tortuosity, non-planarity and complex geometry effects cannot be accounted for in 1-D models. This may lead to errors in the estimation of mean pressure. To evaluate these errors, we simulated steady flow in a patient specific model of the entire systemic circulation using a standard CFD code with Newtonian and non-Newtonian blood properties and compared the pressure evolution along three principal and representative arterial pathlines with the prediction of mean pressure, as given by the 1-D model. Pressure drop computed from aortic root up to iliac bifurcation and to distal brachial is less than 1 mmHg and 1-D model predictions agree well with the 3-D model. In smaller vessels like the precerebral and cerebral arteries, the losses are higher (mean pressure drop over 10 mmHg from mean aortic pressure) and are consistently underestimated by the 1-D model. Complex flow patterns resulting from tortuosity, non-planarity and branching yield shear stresses, which are higher than the ones predicted by the 1-D model. In consequence, the 1-D model overestimates mean pressure in peripheral arteries and especially in the cerebral circulation. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2499 / 2505
页数:7
相关论文
共 50 条
  • [41] Patient-Specific 3D Printed Models of Aortic Aneurysm and Aortic Dissection
    Sun, Zhonghua
    Squelch, Andrew
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (04) : 886 - 889
  • [42] From 2D Ultrasound to Patient-Specific 3D Surface Models for Interventional Guidance
    Annangi, Pavan Kumar
    Sudhakar, Prasad
    Washburn, Mike
    2022 44TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2022, : 1516 - 1519
  • [43] Visualization of Blood Flow in AAA Patient-Specific Geometry: 3-D Reconstruction and Simulation Procedures
    Algabri, Yousif A.
    Altwijri, Omar
    Chatpun, Surapong
    BIONANOSCIENCE, 2019, 9 (04) : 966 - 976
  • [44] Visualization of Blood Flow in AAA Patient-Specific Geometry: 3-D Reconstruction and Simulation Procedures
    Yousif A. Algabri
    Omar Altwijri
    Surapong Chatpun
    BioNanoScience, 2019, 9 : 966 - 976
  • [45] Patient-specific miniplates versus patient-specific reconstruction plate: A biomechanical comparison with 3D-printed plates in mandibular reconstruction
    Steffen, Claudius
    Sellenschloh, Kay
    Willsch, Magdalena
    Soares, Ana Prates
    Morlock, Michael M.
    Heiland, Max
    Kreutzer, Kilian
    Huber, Gerd
    Rendenbach, Carsten
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 140
  • [46] A Method for 3-D Printing Patient-Specific Prosthetic Arms With High Accuracy Shape and Size
    Cabibihan, John-John
    Abubasha, M. Khaleel
    Thakor, Nitish
    IEEE ACCESS, 2018, 6 : 25029 - 25039
  • [47] Manufacturing Patient-Specific Phantoms to Treat Aneurysms Using Rotational Angiography and 3-D Modeling
    O'Hara, Ryan P.
    Iacobucci, Gary
    Russ, Megan
    Ionita, Ciprian
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2014, VOL 3, 2014,
  • [48] Patient-Specific 3D Printed Models of Renal Tumours Using Home-Made 3D Printer in Comparison with Commercial 3D Printer
    Liu, Dongting
    Sun, Zhonghua
    Chaichana, Thanapong
    Ducke, Werner
    Fan, Zhanming
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (02) : 303 - 308
  • [49] Comparison between 2.5-D and 3-D realistic models for wind field adjustment
    Ferragut, L.
    Montenegro, R.
    Montero, G.
    Rodriguez, E.
    Asensio, M. I.
    Escobar, J. M.
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2010, 98 (10-11) : 548 - 558
  • [50] A Comparison of Radial Diffusion Coefficients in 1-D and 3-D Long-Term Radiation Belt Simulations
    Drozdov, A. Y.
    Allison, H. J.
    Shprits, Y. Y.
    Elkington, S. R.
    Aseev, N. A.
    JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 2021, 126 (08)