Patient-specific mean pressure drop in the systemic arterial tree, a comparison between 1-D and 3-D models

被引:35
|
作者
Reymond, Philippe [1 ]
Perren, Fabienne [2 ]
Lazeyras, Francois [3 ]
Stergiopulos, Nikos
机构
[1] Ecole Polytech Fed Lausanne, Lab Hemodynam & Cardiovasc Technol, EPFL STI IBI2 LHTC, CH-1015 Lausanne, Switzerland
[2] Univ Hosp & Med Fac Geneva, Dept Clin Neurosci, Neurosonol Unit, Geneva, Switzerland
[3] Univ Hosp & Med Fac Geneva, Dept Radiol, Geneva, Switzerland
关键词
Cerebral circulation; CFD; Wave propagation; MRA; Non-Newtonian blood; PULSE-WAVE PROPAGATION; ONE-DIMENSIONAL MODEL; BLOOD-FLOW; COMPUTER-SIMULATION; MATHEMATICAL-MODEL; VALIDATION; WILLIS; CIRCLE; CIRCULATION; NETWORKS;
D O I
10.1016/j.jbiomech.2012.07.020
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
One-dimensional models of the systemic arterial tree are useful tools for studying wave propagation phenomena, however, their formulation for frictional losses is approximate and often based on solutions for developed flow in straight non-tapered arterial segments. Thus, losses due to bifurcations, tortuosity, non-planarity and complex geometry effects cannot be accounted for in 1-D models. This may lead to errors in the estimation of mean pressure. To evaluate these errors, we simulated steady flow in a patient specific model of the entire systemic circulation using a standard CFD code with Newtonian and non-Newtonian blood properties and compared the pressure evolution along three principal and representative arterial pathlines with the prediction of mean pressure, as given by the 1-D model. Pressure drop computed from aortic root up to iliac bifurcation and to distal brachial is less than 1 mmHg and 1-D model predictions agree well with the 3-D model. In smaller vessels like the precerebral and cerebral arteries, the losses are higher (mean pressure drop over 10 mmHg from mean aortic pressure) and are consistently underestimated by the 1-D model. Complex flow patterns resulting from tortuosity, non-planarity and branching yield shear stresses, which are higher than the ones predicted by the 1-D model. In consequence, the 1-D model overestimates mean pressure in peripheral arteries and especially in the cerebral circulation. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2499 / 2505
页数:7
相关论文
共 50 条
  • [21] Comparison between 1-D and grey-box models of a SOFC
    Moradi, Ramin
    Di Carlo, Andrea
    Testa, Federico
    Del Zotto, Luca
    Bocci, Enrico
    Habib, Emanuele
    XII INTERNATIONAL CONFERENCE ON COMPUTATIONAL HEAT, MASS AND MOMENTUM TRANSFER (ICCHMT 2019), 2019, 128
  • [22] The technique for 3D printing patient-specific models for auricular reconstruction
    Flores, Roberto L.
    Liss, Hannah
    Raffaelli, Samuel
    Humayun, Aiza
    Khouri, Kimberly S.
    Coelho, Paulo G.
    Witek, Lukasz
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (06) : 937 - 943
  • [23] Patient-Specific 3D Bioprinted Models of Developing Human Heart
    Cetnar, Alexander D.
    Tomov, Martin L.
    Ning, Liqun
    Jing, Bowen
    Theus, Andrea S.
    Kumar, Akaash
    Wijntjes, Amanda N.
    Bhamidipati, Sai Raviteja
    Do, Katherine Pham
    Mantalaris, Athanasios
    Oshinski, John N.
    Avazmohammadi, Reza
    Lindsey, Brooks D.
    Bauser-Heaton, Holly D.
    Serpooshan, Vahid
    ADVANCED HEALTHCARE MATERIALS, 2021, 10 (15)
  • [24] Patient-Specific Instrumentation Accuracy Evaluated with 3D Virtual Models
    Leon-Munoz, Vicente J.
    Parrinello, Andrea
    Manca, Silvio
    Galloni, Gianluca
    Lopez-Lopez, Mirian
    Martinez-Martinez, Francisco
    Santonja-Medina, Fernando
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (07)
  • [25] Real-Time Patient-Specific ECG Classification by 1-D Convolutional Neural Networks
    Kiranyaz, Serkan
    Ince, Turker
    Gabbouj, Moncef
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (03) : 664 - 675
  • [26] PATIENT-SPECIFIC 3-D LUNG MODELING: THE FUTURE OF PRECISION LUNG CANCER SURGERY?
    Baig, Mirza Zain
    Muslim, Zaid
    Bhora, Faiz
    CHEST, 2020, 158 (04) : 1441A - 1441A
  • [27] Comparison of 3 Pediatric Pelvic Osteotomies for Acetabular Dysplasia Using Patient-specific 3D-printed Models
    Caffrey, Jason P.
    Jeffords, Megan E.
    Farnsworth, Christine L.
    Bomar, James D.
    Upasani, Vidyadhar V.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2019, 39 (03) : E159 - E164
  • [28] Carotid Web Quantification: Comparative Analysis Between 1-D, 2-D and 3-D Methods
    da Camara, Catarina Perry
    Nogueira, Raul G.
    Alhamza, Al-Bayati
    Bouslama, Mehdi
    Pisani, Leonardo
    Mohammaden, Mahmoud
    Frankel, Michael
    Haussen, Diogo C.
    STROKE, 2020, 51
  • [29] Validation of the CATHARE 1-D and 3-D reflood models against FEBA and ACHILLES experimental tests
    Lutsanych, S.
    Moretti, F.
    D'Auria, F.
    NUCLEAR ENGINEERING AND DESIGN, 2017, 321 : 266 - 277
  • [30] Using 1-D models to interpret the reflectance anisotropy of 3-D canopy targets: Issues and caveats
    Widlowski, JL
    Pinty, B
    Lavergne, T
    Verstraete, MM
    Gobron, N
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2005, 43 (09): : 2008 - 2017