Patient-specific mean pressure drop in the systemic arterial tree, a comparison between 1-D and 3-D models

被引:35
|
作者
Reymond, Philippe [1 ]
Perren, Fabienne [2 ]
Lazeyras, Francois [3 ]
Stergiopulos, Nikos
机构
[1] Ecole Polytech Fed Lausanne, Lab Hemodynam & Cardiovasc Technol, EPFL STI IBI2 LHTC, CH-1015 Lausanne, Switzerland
[2] Univ Hosp & Med Fac Geneva, Dept Clin Neurosci, Neurosonol Unit, Geneva, Switzerland
[3] Univ Hosp & Med Fac Geneva, Dept Radiol, Geneva, Switzerland
关键词
Cerebral circulation; CFD; Wave propagation; MRA; Non-Newtonian blood; PULSE-WAVE PROPAGATION; ONE-DIMENSIONAL MODEL; BLOOD-FLOW; COMPUTER-SIMULATION; MATHEMATICAL-MODEL; VALIDATION; WILLIS; CIRCLE; CIRCULATION; NETWORKS;
D O I
10.1016/j.jbiomech.2012.07.020
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
One-dimensional models of the systemic arterial tree are useful tools for studying wave propagation phenomena, however, their formulation for frictional losses is approximate and often based on solutions for developed flow in straight non-tapered arterial segments. Thus, losses due to bifurcations, tortuosity, non-planarity and complex geometry effects cannot be accounted for in 1-D models. This may lead to errors in the estimation of mean pressure. To evaluate these errors, we simulated steady flow in a patient specific model of the entire systemic circulation using a standard CFD code with Newtonian and non-Newtonian blood properties and compared the pressure evolution along three principal and representative arterial pathlines with the prediction of mean pressure, as given by the 1-D model. Pressure drop computed from aortic root up to iliac bifurcation and to distal brachial is less than 1 mmHg and 1-D model predictions agree well with the 3-D model. In smaller vessels like the precerebral and cerebral arteries, the losses are higher (mean pressure drop over 10 mmHg from mean aortic pressure) and are consistently underestimated by the 1-D model. Complex flow patterns resulting from tortuosity, non-planarity and branching yield shear stresses, which are higher than the ones predicted by the 1-D model. In consequence, the 1-D model overestimates mean pressure in peripheral arteries and especially in the cerebral circulation. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2499 / 2505
页数:7
相关论文
共 50 条
  • [1] A systematic comparison between 1-D and 3-D hemodynamics in compliant arterial models
    Xiao, Nan
    Alastruey, Jordi
    Figueroa, C. Alberto
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2014, 30 (02) : 204 - 231
  • [2] 3-D convection models:: Are they compatible with 1-D models
    Nordlund, Å
    Stein, RF
    IMPACT OF LARGE-SCALE SURVEYS ON PULSATING STAR RESEARCH, 2000, 203 : 362 - 372
  • [3] Application Of 1-D And 3-D Models In A Regional Context
    Paydar, Z.
    Khan, S.
    Rana, T.
    MODSIM 2005: INTERNATIONAL CONGRESS ON MODELLING AND SIMULATION: ADVANCES AND APPLICATIONS FOR MANAGEMENT AND DECISION MAKING: ADVANCES AND APPLICATIONS FOR MANAGEMENT AND DECISION MAKING, 2005, : 2939 - 2945
  • [4] Computational Patient-Specific Models Based on 3-D Ultrasound Data to Quantify Uterine Arterial Flow During Pregnancy
    Pennati, Giancarlo
    Socci, Laura
    Rigano, Serena
    Boito, Simona
    Ferrazzi, Enrico
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (12) : 1715 - 1722
  • [5] Comparison of 1-D and 3-D simulations of the twisting of a thermoviscoplastic tube
    Batra, RC
    Adulla, C
    Wright, TW
    INTERNATIONAL JOURNAL OF PLASTICITY, 1996, 12 (01) : 29 - 33
  • [6] P8.13 A 1-D Model of the Systemic Arterial Tree in Mice
    L. Aslanidou
    B. Trachet
    P. Reymond
    P. Segers
    N. Stergiopulos
    Artery Research, 2014, 8 (4) : 154 - 154
  • [7] Physiologically Based Construction of Optimized 3-D Arterial Tree Models
    Schneider, Matthias
    Hirsch, Sven
    Weber, Bruno
    Szekely, Gabor
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT I, 2011, 6891 : 404 - +
  • [8] Physiological simulation of blood flow in the aorta: Comparison of hemodynamic indices as predicted by 3-D FSI, 3-D rigid wall and 1-D models
    Reymond, Philippe
    Crosetto, Paolo
    Deparis, Simone
    Quarteroni, Alfio
    Stergiopulos, Nikos
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (06) : 784 - 791
  • [9] Evaluating 3-D and 1-D mathematical models for mass transport in heterogeneous biofilms
    Morgenroth, E
    Eberl, H
    van Loosdrecht, MCM
    WATER SCIENCE AND TECHNOLOGY, 2000, 41 (4-5) : 347 - 356
  • [10] Semantic Annotation of Patient-Specific 3D Anatomical Models
    Banerjee, Imon
    Agibetov, Asan
    Catalano, Chiara Eva
    Patane, Giuseppe
    Spagnuolo, Michela
    2015 INTERNATIONAL CONFERENCE ON CYBERWORLDS (CW), 2015, : 22 - 29