Noise Analysis for Interference Waveform in Swept Source Optical Coherence Tomography

被引:0
|
作者
Sunaga, Hiroshi [1 ]
Endo, Kazuma [1 ]
Ogawa, Takafumi [1 ]
Shinagawa, Mitsuru [1 ]
Ueno, Masahiro [2 ]
Toyoda, Seiji [2 ]
Sasaki, Yuzo [2 ]
Chin, Meishin [2 ]
Sakamoto, Tadashi [2 ]
机构
[1] Hosei Univ, Fac Sci & Engn, 3-7-2 Kajino Cho, Koganei, Tokyo 1848584, Japan
[2] NTT Corp, NTT Device Innovat Ctr, 3-1 Morinosato, Atsugi, Kanagawa 2430198, Japan
关键词
SS-OCT; Simulation; Interference waveform; Voltage noise; Jitter; HIGH-SPEED; ULTRAHIGH-RESOLUTION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes a noise analysis of interference waveforms in swept source optical coherence tomography using a KTa1-XNbXO3 deflector. Noise reduction based on such analysis is needed for obtaining high-resolution images. The quality of the tomographic images depends on the signal-to-noise ratio (SNR) of the point spread functions (PSFs). The relationship between the noise of the interference waveform and the PSFs' SNR was investigated using a simulation. Two kinds of noise were revealed: voltage noise and jitter. We found that the PSFs' SNR deterioration caused by jitter was greater than that caused by voltage noise. We found that the PSFs' SNR is substantially limited by the typical jitter of 0.5 ns.
引用
收藏
页码:957 / 962
页数:6
相关论文
共 50 条
  • [1] Phase-noise analysis of swept-source optical coherence tomography systems
    Ling, Yuye
    Gan, Yu
    Yao, Xinwen
    Hendon, Christine P.
    OPTICS LETTERS, 2017, 42 (07) : 1333 - 1336
  • [2] Swept Source Optical Coherence Tomography: a Review
    Yasin Alibhai A.
    Or C.
    Witkin A.J.
    Current Ophthalmology Reports, 2018, 6 (1) : 7 - 16
  • [3] Advances in swept-source optical coherence tomography and optical coherence tomography angiography
    Zheng, Fang
    Deng, Xiaofeng
    Zhang, Qi
    He, Jingliang
    Ye, Panpan
    Liu, Shan
    Li, Peng
    Zhou, Jian
    Fang, Xiaoyun
    ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH, 2023, 3 (02): : 67 - 79
  • [4] Analysis of performance improvement in a swept source for optical coherence tomography applications
    Yang, Zhiwei
    Wu, Xu
    Ouyang, Deqin
    Sun, Huibin
    Ruan, Shuangchen
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2020, 59 (03)
  • [5] Noise Reduction of Swept-Source Optical Coherence Tomography via Compressed Sensing
    Luo, Site
    Guo, Qiang
    Zhao, Hui
    An, Xin
    Zhou, Liang
    Xie, Huikai
    Tang, Jianyu
    Wang, Xiao
    Chen, Hongwei
    Huo, Li
    IEEE PHOTONICS JOURNAL, 2018, 10 (01):
  • [6] Handheld swept source optical coherence tomography angiography
    Liu, Gangjun
    Yang, Jianlong
    Liu, Liang
    Campbell, J. Peter
    Huang, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [7] Swept source optical coherence tomography in globe perforation
    Dubey, Devashish
    Shanmugam, Mahesh
    Ramanjulu, Rajesh
    Mishra, K. C. Divyansh
    Doshi, Bindiya
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (10) : 1697 - +
  • [8] MHz Swept Source Optical Coherence Tomography of the Choriocapillaris
    Schmoll, Tilman
    Niederleithner, Michael
    Britten, Anja
    Matten, Philipp
    Bello, Simon
    Kubach, Sophie
    Drexler, Wolfgang
    Leitgeb, Rainer
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (11)
  • [9] Fast Broadband Swept Source for Optical Coherence Tomography
    Cordes, A. H.
    Vilela de Faria, G.
    von der Weid, J. P.
    2009 SBMO/IEEE MTT-S INTERNATIONAL MICROWAVE AND OPTOELECTRONICS CONFERENCE (IMOC 2009), 2009, : 143 - 146
  • [10] Swept Source optical coherence tomography of choroidal nevi
    Michalewska, Zofia
    Michalewski, Janusz
    Nawrocki, Jerzy
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2016, 51 (04): : 271 - 276