Noise Analysis for Interference Waveform in Swept Source Optical Coherence Tomography

被引:0
|
作者
Sunaga, Hiroshi [1 ]
Endo, Kazuma [1 ]
Ogawa, Takafumi [1 ]
Shinagawa, Mitsuru [1 ]
Ueno, Masahiro [2 ]
Toyoda, Seiji [2 ]
Sasaki, Yuzo [2 ]
Chin, Meishin [2 ]
Sakamoto, Tadashi [2 ]
机构
[1] Hosei Univ, Fac Sci & Engn, 3-7-2 Kajino Cho, Koganei, Tokyo 1848584, Japan
[2] NTT Corp, NTT Device Innovat Ctr, 3-1 Morinosato, Atsugi, Kanagawa 2430198, Japan
关键词
SS-OCT; Simulation; Interference waveform; Voltage noise; Jitter; HIGH-SPEED; ULTRAHIGH-RESOLUTION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes a noise analysis of interference waveforms in swept source optical coherence tomography using a KTa1-XNbXO3 deflector. Noise reduction based on such analysis is needed for obtaining high-resolution images. The quality of the tomographic images depends on the signal-to-noise ratio (SNR) of the point spread functions (PSFs). The relationship between the noise of the interference waveform and the PSFs' SNR was investigated using a simulation. Two kinds of noise were revealed: voltage noise and jitter. We found that the PSFs' SNR deterioration caused by jitter was greater than that caused by voltage noise. We found that the PSFs' SNR is substantially limited by the typical jitter of 0.5 ns.
引用
收藏
页码:957 / 962
页数:6
相关论文
共 50 条
  • [41] Swept source optical coherence tomography imaging of optic disc melanocytoma
    Filloy, Alejandro
    Arias, Luis
    Ascaso, Francisco J.
    Caminal, Josep M.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 45 (03): : 313 - 314
  • [42] Swept source optical coherence tomography imaging of a series of choroidal tumours
    Filloy, Alejandro
    Caminal, Josep M.
    Arias, Luis
    Jordan, Sara
    Catala, Jaume
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2015, 50 (03): : 242 - 248
  • [43] Swept-Source Optical Coherence Tomography Features of Choroidal Nevi
    Francis, Jasmine H.
    Pang, Claudine E.
    Abramson, David H.
    Milman, Tatyana
    Folberg, Robert
    Mrejen, Sarah
    Freund, K. Bailey
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (01) : 169 - 176
  • [44] Swept-Source Optical Coherence Tomography-Supervised Biopsy
    Xu, Qiuyun
    Adabi, Saba
    Clayton, Anne
    Daveluy, Steven
    Mehregan, Darius
    Nasiriavanaki, Mohammadreza
    DERMATOLOGIC SURGERY, 2018, 44 (06) : 768 - 775
  • [45] A comparative analysis of choroidal thickness map in healthy eyes using spectral domain optical coherence tomography and swept source optical coherence tomography
    Lee, Byung Ro
    Shin, Yong Un
    Lim, Han Woong
    Lee, Sang Hyup
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [46] Frequency multiplexed long range swept source optical coherence tomography
    Zurauskas, Mantas
    Bradu, Adrian
    Podoleanu, Adrian Gh.
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (06): : 778 - 788
  • [47] Electron-injection Detectors for Swept Source Optical Coherence Tomography
    Fathipour, V.
    Mohseni, H.
    2015 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2015,
  • [48] Wavenumber calibration and phase measurement in swept source optical coherence tomography
    Shangguan Zi-Wei
    Shen Yi
    Li Peng
    Ding Zhi-Hua
    ACTA PHYSICA SINICA, 2016, 65 (03)
  • [49] Gastric and Colon Cancer Imaging with Swept Source Optical Coherence Tomography
    Luo, Site
    Liu, Hao
    Zhao, Hui
    An, Xin
    Xie, Huikai
    Huo, Li
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2017,
  • [50] Swept source optical coherence tomography based on scanning fiber probe
    Wu, Tong
    Ding, Zhihua
    Wang, Kai
    Xu, Lei
    Chen, Minghui
    Wang, Chuan
    Guangxue Xuebao/Acta Optica Sinica, 2009, 29 (SUPPL.): : 37 - 41