Dosimetric verification of treatment planning system superficial dose calculations for proton beam

被引:2
|
作者
Rah, Jeong-Eun [1 ]
Shin, Dongho [2 ]
Park, Jeong-hoon [2 ]
Hwang, Ui-Jung [3 ]
Oh, Do Hoon [1 ]
Park, Sung Yong [4 ]
机构
[1] Kwandong Univ, Coll Med, Myongji Hosp, Dept Radiat Oncol, Goyang, South Korea
[2] Natl Canc Ctr, Proton Therapy Ctr, Goyang, South Korea
[3] Natl Med Ctr, Dept Radiat Oncol, Seoul, South Korea
[4] McLaren Canc Inst, Proton Therapy Ctr, Flint, MI USA
关键词
Proton beam; Superficial dose; Glass dosimeter; Dose verification; GLASS DOSIMETER;
D O I
10.1016/j.radmeas.2013.02.015
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
To investigate the accuracy of Eclipse treatment planning system (TPS) dose calculations at the surface. It is desirable to know the accuracy of the proton treatment planning system in predicting dose at superficial region. All measurements were performed in a clinical proton beam at the National Cancer Center in Korea. Proton treatment plans were developed for a superficial planning target volume (PTV) contoured on a cylindrical polymethylmethacrylate phantom specially designed for this study. Dose was then measured at the surface and also in the PTV for these treatment plans and compared against the TPS calculations. For our study, a model GD-301 glass dosimeters were used. The proton treatment planning system overestimated the superficial dose without use of bolus as much as by 7-14% when compared to glass dosimeter. On the other hand, with use of bolus to cover the superficial region, surface dose between the calculation from Eclipse and measurement using the glass dosimeter are approximately within 3%. Published by Elsevier Ltd.
引用
收藏
页码:60 / 63
页数:4
相关论文
共 50 条
  • [1] Dosimetric Verification of HDR Treatment Planning System Dose Calculations by Farmer Chamber Measurements in Water
    Corrao, A.
    Cardarelli, G.
    Mihaylov, I.
    Curran, B.
    Sternick, E.
    MEDICAL PHYSICS, 2010, 37 (06) : 3199 - +
  • [2] THE DOSIMETRIC VERIFICATION OF A PENCIL BEAM BASED TREATMENT PLANNING SYSTEM
    KNOOS, T
    CEBERG, C
    WEBER, L
    NILSSON, P
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (10): : 1609 - 1628
  • [3] Dosimetric verification of clinical radiotherapy treatment planning system
    Kolarevic, Goran
    Jaros, Drazan
    Marosevic, Goran
    Ignjatic, Dejan
    Mirjanic, Dragoljub
    VOJNOSANITETSKI PREGLED, 2022, 79 (02) : 115 - 124
  • [4] Dosimetric verification of a clinical inverse treatment planning system
    Xing, L
    Findley, D
    Ma, L
    Ma, CM
    Forster, K
    Boyer, AL
    RADIOLOGY, 1998, 209P : 397 - 397
  • [5] Dosimetric verification of a Monte Carlo treatment planning system for MR-guided proton therapy
    Fuchs, H.
    Padilla-Cabal, F.
    Oborn, B.
    Traneus, E.
    Georg, D.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1544 - S1545
  • [6] Dosimetric verification of a commercial inverse treatment planning system
    Lei, X
    Curran, B
    Hill, R
    Holmes, T
    Ma, LJ
    Forster, KM
    Boyer, AL
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (02): : 463 - 478
  • [7] Surface and superficial dose dosimetric verification for postmastectomy radiotherapy
    Shiau, An-Cheng
    Chiu, Min-Chi
    Chen, Tung-Ho
    Chiou, Jeng-Fong
    Shueng, Pei-Wei
    Chen, Shang-Wen
    Chen, Wei-Li
    Kuan, Wei-Peng
    MEDICAL DOSIMETRY, 2012, 37 (04) : 417 - 424
  • [8] Dosimetric verification of a high dose rate brachytherapy treatment planning system in homogeneous and heterogeneous media
    Uniyal, S. C.
    Sharma, S. D.
    Naithani, U. C.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (02): : 171 - 177
  • [9] Independent verification of treatment planning system calculations
    Dabrowska-Szewczyk, Edyta
    Zawadzka, Anna
    Brzozowska, Beata
    Walewska, Agnieszka
    Kukolowicz, Pawel
    NUKLEONIKA, 2021, 66 (02) : 47 - 53
  • [10] Independent verification of treatment planning system calculations
    Dabrowska, E.
    Brzozowska, B.
    Walewska, A.
    Kukolowicz, P.
    Zawadzka, A.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S1004 - S1005