Uncertainty associated with the leaching of aerosol filters for the determination of metals in aerosol particulate matter using collision/reaction cell ICP-MS detection

被引:14
|
作者
Clough, Robert [1 ]
Lohan, Maeve C. [1 ,2 ]
Ussher, Simon J. [1 ]
Nimmo, Malcolm [1 ]
Worsfold, Paul J. [1 ]
机构
[1] Plymouth Univ, Sch Geog Earth & Environm Sci, Biogeochem Res Ctr, Plymouth PL4 8AA, Devon, England
[2] Univ Southampton, Natl Oceanog Ctr Southampton, Ocean & Earth Sci, Southampton SO14 3ZH, Hants, England
基金
英国自然环境研究理事会;
关键词
Uncertainty; Aerosol; Leach; ICP-MS; Cobalt; Iron; Lead; Vanadium; IRON; SOLUBILITY; FE; PHYTOPLANKTON;
D O I
10.1016/j.talanta.2019.02.067
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
High quality observational data with a firm uncertainty assessment are essential for the proper validation of biogeochemical models for trace metals such as iron. Typically, concentrations of these metals are very low in oceanic waters (nM and sub nM) and ICP-MS is therefore a favoured technique for quantitative analysis. Uncertainties in the measurement step are generally well constrained, even at sub-nM concentrations. However, the measurement step is only part of the overall procedure. For the determination of trace metal solubilities from aerosols in the surface ocean, aerosol collection on a filter paper followed by a leaching procedure is likely to make a significant contribution to the overall uncertainty. This paper quantifies the uncertainties for key trace metals (cobalt, iron, lead and vanadium), together with aluminium as a reference element, for a controlled, flow through laboratory leaching procedure using filters collected from three different sampling sites (Tudor Hill (Bermuda), Heraklion (Crete) and Tel-Shikmona (Israel)) and water, glucuronic acid and desferrioxamine B as leachants. Relative expanded uncertainties were in the range of 12-29% for cobalt, 12-62% for iron, 13-45% for lead and 5-11% for vanadium. Fractional solubilities for iron ranged from 0.2 +/- 0.1% to 16.9 +/- 3.5%.
引用
收藏
页码:425 / 430
页数:6
相关论文
共 49 条
  • [31] Simultaneous determination of P and S in human serum, blood plasma and whole blood by ICP-MS with collision/reaction cell technology
    Gong, Zi-Shan
    Yang, Ru
    Sun, Chuan-Qiang
    Han, Wen-Nian
    Jiang, Xue-Hui
    Xu, Shu-Xin
    Wang, Yan
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2019, 445
  • [32] Determination of Silver in Geological Samples Using Aerosol Dilution ICP-MS After Water-bath Extraction with Inverse Aqua Regia
    Wu, Yan
    Huang, Dingming
    Feng, Tong
    Jin, Lanlan
    Xiong, Dan
    Yu, Jie
    Xu, Qian
    Huang, Ruimin
    Hu, Shenghong
    ATOMIC SPECTROSCOPY, 2021, 42 (06) : 374 - 382
  • [33] Filter-based measurements of airborne particulate matter and metals in indoor environments using OPSIS SM200 system and ICP-MS
    Niu, Jianjun
    Rasmussen, Pat
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 250
  • [34] Total polyphenol content and metals determination in Spanish virgin olive oils by means of a dispersive liquid-liquid aerosol phase extraction method and ICP-MS
    Miron, Carolina
    Sanchez, Raquel
    Prats, Soledad
    Todoli, Jose-Luis
    ANALYTICA CHIMICA ACTA, 2020, 1094 (1094) : 34 - 46
  • [35] Optimisation of ICP-MS collision/reaction cell conditions for the determination of elements likely to be interfered (V, Cr, Fe, Co, Ni, As and Se) in foodstuffs
    Kadar, Ali
    Noel, Laurent
    Chekri, Rachida
    Vastel, Christelle
    Millour, Sandrine
    Guerin, Thierry
    TALANTA, 2011, 85 (05) : 2605 - 2613
  • [36] Exploiting aerosol dilution for the determination of ultra-trace elements in honey by collision/reaction cell inductively coupled plasma mass spectrometry (CRC-ICP-MS) without thermal digestion
    Doker, Serhat
    ANALYTICAL METHODS, 2017, 9 (11) : 1710 - 1717
  • [37] Evaluation of airborne particulate matter and metals data in personal, indoor and outdoor environments using ED-XRF and ICP-MS and co-located duplicate samples
    Niu, Jianjun
    Rasmussen, Pat E.
    Wheeler, Amanda
    Williams, Ron
    Chenier, Marc
    ATMOSPHERIC ENVIRONMENT, 2010, 44 (02) : 235 - 245
  • [38] Determination of As and Se in coal and coal combustion products using closed vessel microwave digestion and collision/reaction cell technology (CCT) of inductively coupled plasma mass spectrometry (ICP-MS)
    Li, Xiao
    Dai, Shifeng
    Zhang, Weiguo
    Li, Tian
    Zheng, Xin
    Chen, Wenmei
    INTERNATIONAL JOURNAL OF COAL GEOLOGY, 2014, 124 : 1 - 4
  • [39] Analysis of twenty five impurities in uranium matrix by ICP-MS with iron measurement optimized by using reaction collision cell, cold plasma or medium resolution
    Quemet, Alexandre
    Brennetot, Rene
    Chevalier, Emilie
    Prian, Edwina
    Laridon, Anne-Laure
    Mariet, Clarisse
    Fichet, Pascal
    Laszak, Ivan
    Goutelard, Florence
    TALANTA, 2012, 99 : 207 - 212
  • [40] Optimisation of the operating conditions of a quadrupole ICP-MS with hexapole collision/reaction cell for the analysis of selenium-79 in spent nuclear fuel using experimental designs
    Brennetot, Rene
    Pierry, Laurence
    Atamyan, Teoman
    Favre, Georges
    Vailhen, Dominique
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (10) : 1350 - 1358