Uncertainty associated with the leaching of aerosol filters for the determination of metals in aerosol particulate matter using collision/reaction cell ICP-MS detection

被引:14
|
作者
Clough, Robert [1 ]
Lohan, Maeve C. [1 ,2 ]
Ussher, Simon J. [1 ]
Nimmo, Malcolm [1 ]
Worsfold, Paul J. [1 ]
机构
[1] Plymouth Univ, Sch Geog Earth & Environm Sci, Biogeochem Res Ctr, Plymouth PL4 8AA, Devon, England
[2] Univ Southampton, Natl Oceanog Ctr Southampton, Ocean & Earth Sci, Southampton SO14 3ZH, Hants, England
基金
英国自然环境研究理事会;
关键词
Uncertainty; Aerosol; Leach; ICP-MS; Cobalt; Iron; Lead; Vanadium; IRON; SOLUBILITY; FE; PHYTOPLANKTON;
D O I
10.1016/j.talanta.2019.02.067
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
High quality observational data with a firm uncertainty assessment are essential for the proper validation of biogeochemical models for trace metals such as iron. Typically, concentrations of these metals are very low in oceanic waters (nM and sub nM) and ICP-MS is therefore a favoured technique for quantitative analysis. Uncertainties in the measurement step are generally well constrained, even at sub-nM concentrations. However, the measurement step is only part of the overall procedure. For the determination of trace metal solubilities from aerosols in the surface ocean, aerosol collection on a filter paper followed by a leaching procedure is likely to make a significant contribution to the overall uncertainty. This paper quantifies the uncertainties for key trace metals (cobalt, iron, lead and vanadium), together with aluminium as a reference element, for a controlled, flow through laboratory leaching procedure using filters collected from three different sampling sites (Tudor Hill (Bermuda), Heraklion (Crete) and Tel-Shikmona (Israel)) and water, glucuronic acid and desferrioxamine B as leachants. Relative expanded uncertainties were in the range of 12-29% for cobalt, 12-62% for iron, 13-45% for lead and 5-11% for vanadium. Fractional solubilities for iron ranged from 0.2 +/- 0.1% to 16.9 +/- 3.5%.
引用
收藏
页码:425 / 430
页数:6
相关论文
共 49 条
  • [21] Polyatomic interference removal using a collision reaction interface for plutonium determination in the femtogram range by quadrupole ICP-MS
    Olufson, Kylie P.
    Moran, Grainne
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 308 (02) : 639 - 647
  • [22] Polyatomic interference removal using a collision reaction interface for plutonium determination in the femtogram range by quadrupole ICP-MS
    Kylie P. Olufson
    Grainne Moran
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 308 : 639 - 647
  • [23] Improved chromium determination in various food matrices using dynamic reaction cell ICP-MS
    Hammer, D
    Nicolas, M
    Andrey, D
    ATOMIC SPECTROSCOPY, 2005, 26 (06) : 203 - 208
  • [24] Determination of 90Sr in large mass of apples and cabbages by triple quadruple collision/reaction cell ICP-MS
    Zhong, Ningjie
    Zhao, Xinghong
    Li, Lili
    Xu, Changkun
    Huang, Shenghui
    Zhao, Lifei
    Zhao, Yonggang
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2025, 334 (01) : 131 - 140
  • [25] A simple, rapid method for simultaneous determination of multiple elements in serum by using an ICP-MS equipped with collision cell
    Guofu Zhang
    Fengquan Zhang
    Wannian Liu
    Chili Liu
    Jing You
    Meichen Tian
    Tingting Cao
    Jing Jiang
    Zhongzhi Yang
    Hui Wu
    Weidong Wu
    BMC Chemistry, 17
  • [26] A simple, rapid method for simultaneous determination of multiple elements in serum by using an ICP-MS equipped with collision cell
    Zhang, Guofu
    Zhang, Fengquan
    Liu, Wannian
    Liu, Chili
    You, Jing
    Tian, Meichen
    Cao, Tingting
    Jiang, Jing
    Yang, Zhongzhi
    Wu, Hui
    Wu, Weidong
    BMC CHEMISTRY, 2023, 17 (01)
  • [27] Applications of hydrogen as a collision and reaction cell gas for enhanced measurement capability applied to low level stable and radioactive isotope detection using ICP-MS/MS
    Russell, B.
    Goddard, S. L.
    Mohamud, H.
    Pearson, O.
    Zhang, Y.
    Thompkins, H.
    Brown, R. J. C.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (12) : 2704 - 2714
  • [28] Elemental and isotopic determination of lead (Pb) in particulate matter in the Brazilian city of GoiA¢nia (GO) using ICP-MS technique
    Gemeiner, Hendryk
    Dourado, Thiago de Araujo
    Sulato, Everton Tiago
    Galhardi, Juliana Aparecida
    Fernandes Gomes, Ana Carla
    de Almeida, Eduardo
    Menegario, Amauri Antonio
    Gastmans, Didier
    Kiang, Chang Hung
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2017, 24 (25) : 20616 - 20625
  • [29] Elemental and isotopic determination of lead (Pb) in particulate matter in the Brazilian city of Goiânia (GO) using ICP-MS technique
    Hendryk Gemeiner
    Thiago de Araujo Dourado
    Everton Tiago Sulato
    Juliana Aparecida Galhardi
    Ana Carla Fernandes Gomes
    Eduardo de Almeida
    Amauri Antonio Menegário
    Didier Gastmans
    Chang Hung Kiang
    Environmental Science and Pollution Research, 2017, 24 : 20616 - 20625
  • [30] Uncertainty contributions to the measurement of dissolved Co, Fe, Pb and V in seawater using flow injection with solid phase preconcentration and detection by collision/reaction cell-quadrupole ICP-MS
    Clough, Robert
    Sela, Hagit
    Milne, Angela
    Lohan, Maeve C.
    Tokalioglu, Serife
    Worsfold, Paul J.
    TALANTA, 2015, 133 : 162 - 169