Aortic Vessel Wall Magnetic Resonance Imaging at 3.0 Tesla: A Reproducibility Study of Respiratory Navigator Gated Free-Breathing 3D Black Blood Magnetic Resonance Imaging

被引:22
|
作者
Roes, Stijntje D. [2 ]
Westenberg, Jos J. M. [2 ]
Doornbos, Joost [2 ]
van der Geest, Rob J. [3 ]
Angelie, Emmanuelle [3 ]
de Roos, Albert [2 ]
Stuber, Matthias [1 ,4 ,5 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21287 USA
[2] Leiden Univ, Med Ctr, Dept Radiol, Leiden, Netherlands
[3] Leiden Univ, Med Ctr, Dept Image Proc, Leiden, Netherlands
[4] Johns Hopkins Univ, Dept Med, Baltimore, MD 21287 USA
[5] Johns Hopkins Univ, Dept Elect & Comp Engn, Div MR Res, Baltimore, MD 21287 USA
基金
美国国家卫生研究院;
关键词
aortic vessel wall; 3T MRI; reproducibility; black-blood; respiratory motion suppression; HUMAN ATHEROSCLEROTIC LESIONS; LIPID-LOWERING THERAPY; HIGH-RESOLUTION; THORACIC AORTA; AUTOMATIC SEGMENTATION; RISK-FACTORS; CORONARY; PLAQUES; SIMVASTATIN; MRI;
D O I
10.1002/mrm.21798
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate a free-breathing three-dimensional (3D) dual inversion-recovery (DIR) segmented k-space gradient-echo (turbo field echo [TFE]) imaging sequence at 3T for the quantification of aortic vessel wall dimensions. The effect of respiratory motion suppression on image quality was tested. Furthermore, the reproducibility of the aortic vessel wall measurements was investigated. Seven healthy subjects underwent 3D DIR TFE imaging of the aortic vessel wall with and without respiratory navigator. Subsequently, this sequence with respiratory navigator was performed twice In 10 healthy subjects to test its reproducibility. The signal-to-noise (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and vessel wall volume (VWV) were assessed. Data were compared using the paired t-test, and the reproducibility of VWV measurements was evaluated using intraclass correlation coefficients (ICCs). SNR, CNR, and vessel wall sharpness were superior in scans performed with respiratory navigator compared to scans performed without. The ICCs concerning intraobserver, interobserver, and interscan reproducibility, were excellent (0.99, 0.94, and 0.95, respectively). In conclusion, respiratory motion suppression substantially improves image quality of 3D DIR TFE imaging of the aortic vessel wall at 3T. Furthermore, this optimized technique with respiratory motion suppression enables assessment of aortic vessel wall dimensions with high reproducibility. Magn Reson Med 61:35-44, 2009. (C) 2008 Wiley-Liss, Inc.
引用
收藏
页码:35 / 44
页数:10
相关论文
共 50 条
  • [31] 3D cephalometric analysis using Magnetic Resonance Imaging: validation of accuracy and reproducibility
    Alexander Juerchott
    Muhammad Abdullah Saleem
    Tim Hilgenfeld
    Christian Freudlsperger
    Sebastian Zingler
    Christopher J. Lux
    Martin Bendszus
    Sabine Heiland
    Scientific Reports, 8
  • [32] 3D cephalometric analysis using Magnetic Resonance Imaging: validation of accuracy and reproducibility
    Juerchott, Alexander
    Saleem, Muhammad Abdullah
    Hilgenfeld, Tim
    Freudlsperger, Christian
    Zingler, Sebastian
    Lux, Christopher J.
    Bendszus, Martin
    Heiland, Sabine
    SCIENTIFIC REPORTS, 2018, 8
  • [33] Non-Rigid Motion Compensation in Free-Breathing Myocardial Perfusion Magnetic Resonance Imaging
    Wollny, G.
    Ledesma-Carbayo, M. J.
    Kellman, P.
    Santos, A.
    COMPUTERS IN CARDIOLOGY 2008, VOLS 1 AND 2, 2008, : 465 - +
  • [34] Magnetic resonance coronary angiography with 3D TrueFISP: breath-hold versus respiratory gated imaging
    So, NMC
    Lam, WWM
    Li, D
    Chan, AKY
    Sanderson, JE
    Metreweli, C
    BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (926): : 116 - 121
  • [35] Fourier-Based Linear Systems Description of Free-Breathing Pulmonary Magnetic Resonance Imaging
    Capaldi, D. P. I.
    Svenningsen, S.
    Cunningham, I. A.
    Parraga, G.
    MEDICAL IMAGING 2015: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2015, 9417
  • [36] Fast, free-breathing and motion-minimized techniques for pediatric body magnetic resonance imaging
    Camilo Jaimes
    John E. Kirsch
    Michael S. Gee
    Pediatric Radiology, 2018, 48 : 1197 - 1208
  • [37] Fast, free-breathing and motion-minimized techniques for pediatric body magnetic resonance imaging
    Jaimes, Camilo
    Kirsch, John E.
    Gee, Michael S.
    PEDIATRIC RADIOLOGY, 2018, 48 (09) : 1197 - 1208
  • [38] Quantification of coronary wall enhancement by cardiovascular magnetic resonance imaging: reproducibility study
    Varma, N.
    Indermuehle, A.
    Peel, S.
    Hussain, T.
    Greil, G.
    Botnar, R.
    Nagel, E.
    Puntmann, V.
    EUROPEAN HEART JOURNAL, 2012, 33 : 1023 - 1023
  • [39] Reproducibility of Black Blood Dynamic Contrast-Enhanced Magnetic Resonance Imaging in Aortic Plaques of Atherosclerotic Rabbits
    Calcagno, Claudia
    Vucic, Esad
    Mani, Venkatesh
    Goldschlager, Gregg
    Fayad, Zahi A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (01) : 191 - 198
  • [40] Routine 3D Magnetic Resonance Imaging of Joints
    Kijowski, Richard
    Gold, Garry E.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (04) : 758 - 771