3D cephalometric analysis using Magnetic Resonance Imaging: validation of accuracy and reproducibility

被引:0
|
作者
Alexander Juerchott
Muhammad Abdullah Saleem
Tim Hilgenfeld
Christian Freudlsperger
Sebastian Zingler
Christopher J. Lux
Martin Bendszus
Sabine Heiland
机构
[1] Heidelberg University Hospital,Department of Neuroradiology
[2] Heidelberg University Hospital,Division of Experimental Radiology, Department of Neuroradiology
[3] Heidelberg University Hospital,Department of Oral and Maxillofacial Surgery
[4] Heidelberg University Hospital,Department of Orthodontics and Dentofacial Orthopedics
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to validate geometric accuracy and in vivo reproducibility of landmark-based cephalometric measurements using high-resolution 3D Magnetic Resonance Imaging (MRI) at 3 Tesla. For accuracy validation, 96 angular and 96 linear measurements were taken on a phantom in 3 different positions. In vivo MRI scans were performed on 3 volunteers in five head positions. For each in vivo scan, 27 landmarks were determined from which 19 angles and 26 distances were calculated. Statistical analysis was performed using Bland-Altman analysis, the two one-sided tests procedure and repeated measures one-way analysis of variance. In comparison to ground truth, all MRI-based phantom measurements showed statistical equivalence (p < 0.001) and an excellent agreement in Bland-Altman analysis (bias ranges: −0.090–0.044°, −0.220–0.241 mm). In vivo cephalometric analysis was highly reproducible among the five different head positions in all study participants, without statistical differences for all angles and distances (p > 0.05). Ranges between maximum and minimum in vivo values were consistently smaller than 2° and 2 mm, respectively (average ranges: 0.88°/0.87 mm). In conclusion, this study demonstrates that accurate and reproducible 3D cephalometric analysis can be performed without exposure to ionizing radiation using MRI.
引用
下载
收藏
相关论文
共 50 条
  • [1] 3D cephalometric analysis using Magnetic Resonance Imaging: validation of accuracy and reproducibility
    Juerchott, Alexander
    Saleem, Muhammad Abdullah
    Hilgenfeld, Tim
    Freudlsperger, Christian
    Zingler, Sebastian
    Lux, Christopher J.
    Bendszus, Martin
    Heiland, Sabine
    SCIENTIFIC REPORTS, 2018, 8
  • [2] In vivo reliability of 3D cephalometric landmark determination on magnetic resonance imaging: a feasibility study
    Alexander Juerchott
    Christian Freudlsperger
    Sebastian Zingler
    Muhammad Abdullah Saleem
    Johann M. E. Jende
    Christopher J. Lux
    Martin Bendszus
    Sabine Heiland
    Tim Hilgenfeld
    Clinical Oral Investigations, 2020, 24 : 1339 - 1349
  • [3] In vivo reliability of 3D cephalometric landmark determination on magnetic resonance imaging: a feasibility study
    Juerchott, Alexander
    Freudlsperger, Christian
    Zingler, Sebastian
    Saleem, Muhammad Abdullah
    Jende, Johann M. E.
    Lux, Christopher J.
    Bendszus, Martin
    Heiland, Sabine
    Hilgenfeld, Tim
    CLINICAL ORAL INVESTIGATIONS, 2020, 24 (03) : 1339 - 1349
  • [4] A study on the reproducibility of cephalometric landmarks when undertaking a three-dimensional (3D) cephalometric analysis
    Zamora, Natalia
    Llamas, Jose-Maria
    Cibrian, Rosa
    Gandia, Jose-Luis
    Paredes, Vanessa
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2012, 17 (04): : E678 - E688
  • [5] Reproducibility of 3D free-breathing magnetic resonance coronary vessel wall imaging
    Desai, MY
    Lai, SH
    Barmet, C
    Weiss, RG
    Stuber, M
    EUROPEAN HEART JOURNAL, 2005, 26 (21) : 2320 - 2324
  • [6] 3D Reconstruction in Magnetic Resonance Imaging
    Mikulka, J.
    Bartusek, K.
    PIERS 2010 CAMBRIDGE: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2010, : 1043 - +
  • [7] 3D imaging using magnetic resonance tomosynthesis (MRT) technique
    Kim, Min-Oh
    Zho, Sang-Young
    Kim, Dong-Hyun
    MEDICAL PHYSICS, 2012, 39 (08) : 4733 - 4741
  • [8] Investigation into accuracy and reproducibility of a 3D breast imaging system using multiple stereo cameras
    Henseler, Helga
    Khambay, Balvinder S.
    Bowman, Adrian
    Smith, Joanna
    Siebert, J. Paul
    Oehler, Susanne
    Ju, Xiangyang
    Ayoub, Ashraf
    Ray, Arup K.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2011, 64 (05): : 577 - 582
  • [9] SNR Analysis of 3D Magnetic Resonance Tomosynthesis (MRT) Imaging
    Kim, Min-Oh
    Kim, Dong-Hyun
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [10] Finite element analysis of cancellous bone structure using 3D magnetic resonance imaging
    Bruyère, K
    Carillon, Y
    Follet, H
    Monier, G
    Peyrin, F
    Rumelhart, C
    ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 2000, 108 (1-2) : 177 - 177