Probing Temperature Inside Planar SOFC Short Stack, Modules, and Stack Series

被引:9
|
作者
Yu, Rong [1 ]
Guan, Wanbing [1 ]
Zhou, Xiao-Dong [1 ,2 ]
机构
[1] Chinese Acad Sci, Ningbo Inst Mat Technol & Engn, 1219 Zhongguan West Rd, Ningbo 315201, Zhejiang, Peoples R China
[2] Univ South Carolina, Dept Chem Engn, 541 Main St, Columbia, SC 29208 USA
关键词
OXIDE FUEL-CELL; THERMAL-STRESS ANALYSIS; ANODE-SUPPORTED SOFCS; PERFORMANCE;
D O I
10.1007/s11837-016-2155-z
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Probing temperature inside a solid oxide fuel cell (SOFC) stack lies at the heart of the development of high-performance and stable SOFC systems. In this article, we report our recent work on the direct measurements of the temperature in three types of SOFC systems: a 5-cell short stack, a 30-cell stack module, and a stack series consisting of two 30-cell stack modules. The dependence of temperature on the gas flow rate and current density was studied under a current sweep or steady-state operation. During the current sweep, the temperature inside the 5-cell stack decreased with increasing current, while it increased significantly at the bottom and top of the 30-cell stack. During a steady-state operation, the temperature of the 5-cell stack was stable while it was increased in the 30-cell stack. In the stack series, the maximum temperature gradient reached 190A degrees C when the gas was not preheated. If the gas was preheated and the temperature gradient was reduced to 23A degrees C in the stack series with the presence of a preheating gas and segmented temperature control, this resulted in a low degradation rate.
引用
收藏
页码:247 / 253
页数:7
相关论文
共 50 条
  • [31] Application of Multivariable Regression Model for SOFC Stack Temperature Estimation in System Environment
    Halinen, M.
    Pohjoranta, A.
    Pennanen, J.
    Kiviaho, J.
    FUEL CELLS, 2015, 15 (05) : 749 - 756
  • [32] Durability Testing of a Short SOFC Stack under Direct Internal Steam Reforming of Methane
    Fu, Qingxi
    Freundt, Pierre
    Bomhard, Jakob
    Hauler, Felix
    SOLID OXIDE FUEL CELLS 13 (SOFC-XIII), 2013, 57 (01): : 335 - 342
  • [33] Analyzing different planar biogas-fueled SOFC stack designs and their effects on the flow uniformity
    Ashraf, Muhammad Adeel
    Rashid, Kashif
    Rahimipetroudi, Iman
    Kim, Hyeon Jin
    Dong, Sang Keun
    ENERGY, 2020, 190
  • [34] Degradation Analysis of an SOFC Short Stack Subject to 10,000 h of Operation
    Fang, Qingping
    de Haart, Ute
    Schaefer, Dominik
    Thaler, Florian
    Rangel-Hernandez, Victor
    Peters, Roland
    Blum, Ludger
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (14)
  • [35] 3D transient thermomechanical behaviour of a full scale SOFC short stack
    Peksen, M.
    Al-Masri, A.
    Blum, L.
    Stolten, D.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2013, 38 (10) : 4099 - 4107
  • [36] Numerical evaluation of a parallel fuel feeding SOFC-PEFC system using seal-less planar SOFC stack
    Yokoo, M
    Watanabe, K
    Arakawa, M
    Yamazaki, Y
    JOURNAL OF POWER SOURCES, 2006, 153 (01) : 18 - 28
  • [37] SOFC Stack Internal Temperature Estimation Based on Spatial-temporal Distribution Laws
    Zhao, Weiqi
    Jiang, Jianhua
    Zhang, Haobo
    Qin, Hongchuan
    Li, Xi
    Li, Jian
    2020 CHINESE AUTOMATION CONGRESS (CAC 2020), 2020, : 381 - 385
  • [38] Fabrication and characterization of low-temperature SOFC stack based on GDC electrolyte membrane
    Ding, Jiao
    Liu, Jiang
    Yin, Guoqiang
    JOURNAL OF MEMBRANE SCIENCE, 2011, 371 (1-2) : 219 - 225
  • [39] Development of Residential SOFC CHP System with Flatten Tubular Segmented-in-Series Cells Stack
    Yoshida, H.
    Seyama, T.
    Sobue, T.
    Yamashita, S.
    SOLID OXIDE FUEL CELLS 12 (SOFC XII), 2011, 35 (01): : 97 - 103
  • [40] 3D model calculation for the planar SOFC using multi-channel and stack models
    Yakabe, H
    Ogiwara, T
    Yasuda, I
    SOLID OXIDE FUEL CELLS VII (SOFC VII), 2001, 2001 (16): : 1022 - 1031