Durability Testing of a Short SOFC Stack under Direct Internal Steam Reforming of Methane

被引:2
|
作者
Fu, Qingxi [1 ]
Freundt, Pierre [2 ]
Bomhard, Jakob [1 ]
Hauler, Felix [2 ]
机构
[1] European Inst Energy Res EIFER, Emmy Noether Str 11, D-76131 Karlsruhe, Germany
[2] ElringKlinger AG, D-72581 Dettingen Unter Teck, Erms, Germany
来源
SOLID OXIDE FUEL CELLS 13 (SOFC-XIII) | 2013年 / 57卷 / 01期
关键词
OXIDE FUEL-CELL; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; ANODES;
D O I
10.1149/05701.0335ecst
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
One 5-cell SOFC stack has been tested under both hydrogen and direct internal steam reforming of methane for a total duration of 3200 hours. Electrochemical impedance spectroscopy has been used to monitor the evolution of internal resistances of all repeating units in the stack. It has been found that repeating units in the stack degraded two times faster under direct internal steam reforming of methane (6.7 - 14.4%/kh voltage degradation) than under H-2 (2.3 - 4.0%/kh). In combination with impedance results, this indicates deterioration of the anode as the main cause of degradation for operation under CH4/H2O. The degradation process is at least partially reversible when changing the gas from CH4 to H-2.
引用
收藏
页码:335 / 342
页数:8
相关论文
共 50 条
  • [1] SOFC Stacks Operating under Direct Internal Steam Reforming of Methane
    Fu, Q.
    Freundt, P.
    Bomhard, J.
    Hauler, F.
    FUEL CELLS, 2017, 17 (02) : 151 - 156
  • [2] High-entropy alloy anode for direct internal steam reforming of methane in SOFC
    Lee, Kevin X.
    Hu, Boxun
    Dubey, Pawan K.
    Anisur, M. R.
    Belko, Seraphim
    Aphale, Ashish N.
    Singh, Prabhakar
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (90) : 38372 - 38385
  • [3] Oxide catalysts in indirect internal steam reforming of methane in SOFC
    Aguiar, P
    Ramírez-Cabrera, E
    Laosiripojana, N
    Atkinson, A
    Kershenbaum, LS
    Chadwick, D
    SCIENCE AND TECHNOLOGY IN CATALYSIS 2002, 2003, 145 : 387 - 390
  • [4] Modeling of a SOFC fuelled by methane: From direct internal reforming to gradual internal reforming
    Klein, J-M
    Bultel, Y.
    Georges, S.
    Pons, M.
    CHEMICAL ENGINEERING SCIENCE, 2007, 62 (06) : 1636 - 1649
  • [5] Durability test and degradation behavior of a 2.5 kW SOFC stack with internal reforming of LNG
    Fang, Qingping
    Blum, Ludger
    Batfalsky, Peter
    Menzler, Norbert H.
    Packbier, Ute
    Stolten, Detlef
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2013, 38 (36) : 16344 - 16353
  • [6] Thermodynamic modeling of the power plant based on the SOFC with internal steam reforming of methane
    Ivanov, Peter
    ELECTROCHIMICA ACTA, 2007, 52 (12) : 3921 - 3928
  • [7] Durability of anode supported Solid Oxides Fuel Cells (SOFC) under direct dry-reforming of methane
    Lanzini, A.
    Leone, P.
    Guerra, C.
    Smeacetto, F.
    Brandon, N. P.
    Santarelli, M.
    CHEMICAL ENGINEERING JOURNAL, 2013, 220 : 254 - 263
  • [8] Performance analysis of a SOFC under direct internal reforming conditions
    Janardhanan, Vinod M.
    Heuveline, Vincent
    Deutschmann, Olaf
    JOURNAL OF POWER SOURCES, 2007, 172 (01) : 296 - 307
  • [9] SOFC Running on Steam Reforming of Biogas: External and Internal Reforming
    Authayanun, Suthida
    Pornjarungsak, Thongchat
    Prukpraipadung, Thanawat
    Saebea, Dang
    Arpornwichanop, Amornchai
    Patcharavorachot, Yaneeporn
    PRES2016: 19TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELING AND OPTIMIZATION FOR ENERGY SAVINGS AND POLLUTION REDUCTION, 2016, 52 : 361 - 366
  • [10] Performance analysis of direct steam reforming of methane in SOFC with SDC-based electrolyte
    Saebea, D.
    Authayanun, S.
    Patcharavorachot, Y.
    ENERGY REPORTS, 2020, 6 : 391 - 396