On timing response improvement of an NE213 scintillator attached to two PMTs

被引:2
|
作者
Zare, S. [1 ]
Ghal-Eh, N. [1 ]
Bayat, E. [2 ]
机构
[1] Damghan Univ, Sch Phys, Damghan, Iran
[2] Univ Birjand, Fac Sci, Dept Phys, Bidand, Iran
关键词
Neutron-gamma discrimination; Scintillator; PMT; Timing response; PHOTRACK; DISCRIMINATION; DETECTORS; CODE;
D O I
10.1016/j.radphyschem.2013.04.036
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A 5 cm diameter by 6 cm height NE213 scintillator attached to two XP2282 PHOTONIS photomultiplier tubes (PMTs) exposed to (241)Americium-Berylium (Am-Be) neutron-gamma source has been used for timing response studies. The neutron-gamma discrimination (NGD) measurements based on a modified zero-crossing (ZC) method show that the discrimination quality, usually expressed in figure-of-merit (FoM) and peak-to-valley (P/V) values, has been improved. The timing response evaluated with Monte Carlo light transport code, PHOTRACK, also verifies this improvement. (c) 2013 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:6 / 10
页数:5
相关论文
共 50 条
  • [21] Response function of NE213 scintillator for 0.5-6 MeV neutrons measured by an improved pulse shape discrimination
    Lee, J.H.
    Lee, C.S.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 402 (01): : 147 - 154
  • [22] Absolute measurements of the response function of an NE213 organic liquid scintillator for the neutron energy range up to 206 MeV
    Nakao, N
    Kurosawa, T
    Nakamura, T
    Uwamino, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 463 (1-2): : 275 - 287
  • [23] Response function of NE213 scintillator for 0.5-6 MeV neutrons measured by an improved pulse shape discrimination
    Lee, JH
    Lee, CS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 402 (01): : 147 - 154
  • [25] Measurements of the proton light output function of the organic liquid scintillator NE213 in several detectors
    Hawkes, NP
    Adams, JM
    Bond, DS
    Croft, S
    Jarvis, ON
    Watkins, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (1-2): : 190 - 194
  • [26] Measurement of neutron-induced proton-production energy spectra with NE213 scintillator
    Kajimoto, Tsuyoshi
    Shigyo, Nobuhiro
    Ishibashi, Kenji
    Arakawa, Hiroyuki
    Haight, Robert C.
    Fotiades, Nikolaos
    RADIATION MEASUREMENTS, 2012, 47 (08) : 596 - 608
  • [27] Analytical modeling of the neutron response function of the NE213 organic liquid scintillator in the energy range of 0.2 MeV to 148 MeV
    Pour, H. Gharaghani
    Tajik, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 995
  • [28] A digital waveform discrimination system for an NE213 scintillator using a VXIbus general purpose waveform digitizer
    Kurahashi, T
    Takahashi, H
    Takada, E
    Nakazawa, M
    Iguchi, T
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 457 - 459
  • [29] Neutron measurements on Joint European Torus using an NE213 scintillator with digital pulse shape discrimination
    Esposito, B
    Bertalot, L
    Marocco, D
    Riva, M
    Kaschuck, Y
    Skopintsev, S
    Zimbal, A
    Reginatto, M
    Schuhmacher, H
    Adams, JM
    Murari, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3550 - 3552
  • [30] RESPONSE-FUNCTION MEASUREMENT OF AN NE213 SCINTILLATOR USING THE H-2(D, N)HE-3 REACTION
    AKSOY, A
    COBAN, A
    NAQVI, AA
    KHIARI, FZ
    HANLY, JM
    HOWELL, CR
    TORNOW, W
    FELSHER, PD
    ALOHALI, MA
    WALTER, RL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 337 (2-3): : 486 - 491