Inpatient long-term video-electroencephalographic monitoring event capture audiovisual diagnostic quality

被引:1
|
作者
Terman, Samuel Waller [1 ,6 ]
O'Kula, Susanna S. [2 ,3 ]
Asmar, Melissa Marie [4 ,5 ]
Davis, Kathryn A. [5 ]
Gazzola, Deana M. [3 ]
Lesanu, Rodica [1 ]
George, Laura [1 ]
Selwa, Linda M. [1 ]
Glynn, Simon M. [1 ]
Hill, Chloe E. [1 ]
机构
[1] Univ Michigan, Dept Neurol, Ann Arbor, MI USA
[2] State Univ New York Downstate Hlth Sci Univ, Dept Neurol, Brooklyn, NY USA
[3] NYU, Dept Neurol, New York, NY USA
[4] Emory Univ, Dept Neurol, Atlanta, GA USA
[5] Univ Penn, Dept Neurol, Philadelphia, PA USA
[6] Univ Michigan, Dept Neurol, Taubman 1st Floor,Recept C,1500 Med Ctr Dr,SPC 531, Ann Arbor, MI 48109 USA
关键词
EEG; Quality; Inpatient monitoring; Seizures; EPILEPSY; SAFETY; UNITS;
D O I
10.1016/j.yebeh.2022.108947
中图分类号
B84 [心理学]; C [社会科学总论]; Q98 [人类学];
学科分类号
03 ; 0303 ; 030303 ; 04 ; 0402 ;
摘要
Objectives: Long-term video-electroencephalographic monitoring (LTVEM) represents the gold-standard method to evaluate whether events represent electrographic seizures, but limited work has evaluated the quality of inpatient event capture. We evaluated the frequency of audiovisual factors impairing the ideal electroclinical correlation of seizure-like episodes during LTVEM.Methods: We retrospectively reviewed consecutive inpatient LTVEM studies (11/2019-12/2019) from three academic epilepsy centers. We evaluated all pushbutton events for audiovisual characteristics such as whether the event was narrated, whether the patient was blocked on camera, and what diagnostic challenges impaired the electroencephalographer's ability to understand either the reason the event but-ton was pushed or clinical semiology ("electroclinical correlation"). We determined the percent of events and studies with each outcome.Results: There were 154 studies with 520 pushbutton events. The pushbutton was most commonly acti-vated by patients (41%), followed by nurses (31%) or family (17%). Twenty-nine percent of events repre-sented electrographic seizures, and 78% occurred in the Epilepsy Monitoring Unit. The reason for the push was not stated in 45% of events, and inadequate narration impaired electroclinical correlation in 19% of events. At least one relevant part of the patient's body was blocked during 12% of events, but this impaired electroclinical correlation in only 1% of events. There was at least one factor impairing electro-clinical correlation in 21% of events, most commonly due to incomplete narration (N = 99), lights off (N = 15), or blankets covering the patient (N = 15). At least one factor impaired electroclinical correlation for any event in 36% of studies.Conclusion: Audiovisual factors impairing the electroencephalographer's ability to render an electroclin-ical correlation were common, particularly related to inadequate narration from bedside observers to explain the reason for pushing the button or event semiology. Future efforts to develop targeted counter-measures should address narration challenges and improve inpatient seizure monitoring quality metrics. (c) 2022 Elsevier Inc. All rights reserved.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Safety study of long-term video-electroencephalogram monitoring
    Ley, M.
    Vivanco, R.
    Massot, A.
    Jimenez, J.
    Roquer, J.
    Rocamora, R.
    NEUROLOGIA, 2014, 29 (01): : 21 - 26
  • [32] Long-Term Quantification of Beach Users Using Video Monitoring
    Guillen, Jorge
    Garcia-Olivares, Antonio
    Ojeda, Elena
    Osorio, Andres
    Chic, Oscar
    Gonzalez, Raul
    JOURNAL OF COASTAL RESEARCH, 2008, 24 (06) : 1612 - 1619
  • [33] A Prospective Study on the Cost-Effective Utilization of Long-Term Inpatient Video-EEG Monitoring in a Developing Country
    Chemmanam, Thomas
    Radhakrishnan, Ashalatha
    Sarma, Sankara P.
    Radhakrishnan, Kurupath
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2009, 26 (02) : 123 - 128
  • [34] LONG-TERM MONITORING OF EEG AND POLYGRAPHY - DIAGNOSTIC-SIGNIFICANCE
    BREZNY, I
    BURANOVA, D
    SABAKA, Z
    BARTKO, D
    DRSKOVA, A
    MIKLASOVA, A
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1988, 70 (01): : P4 - P4
  • [35] Diagnostic evolution of vestibular neuritis after long-term monitoring
    Kim, Sunghoon
    Jung, Yoon Kun
    Kim, Min Ji
    Kim, Kyu-Sung
    Kim, Hyun Ji
    BRAZILIAN JOURNAL OF OTORHINOLARYNGOLOGY, 2022, 88 : S14 - S17
  • [36] Long-Term Water Quality Monitoring of a Transboundary River
    Kuzniar, Antoni
    Kowalczyk, Agnieszka
    Kostuch, Marek
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2014, 23 (03): : 1009 - 1015
  • [37] Frequent Additional Epileptogenic Abnormalities Detected with Inpatient Long-Term EEG Monitoring
    Khalid, Ehtesham
    Siddiqui, Khurram
    Sinha, Shobhit
    NEUROLOGY, 2013, 80
  • [38] In-hospital and home-based long-term monitoring of focal epilepsy with a wearable electroencephalographic device: Diagnostic yield and user experience
    Macea, Jaiver
    Bhagubai, Miguel
    Broux, Victoria
    De Vos, Maarten
    Van Paesschen, Wim
    EPILEPSIA, 2023, 64 (04) : 937 - 950
  • [39] The role of patient companions in long-term video-EEG monitoring
    Dericioglu, N
    Albakir, M
    Saygi, S
    SEIZURE-EUROPEAN JOURNAL OF EPILEPSY, 2000, 9 (02): : 124 - 127
  • [40] LONG-TERM VIDEO-ELECTROENCEPHALOGRAPHY IN A CANINE EPILEPSY MONITORING UNIT
    Poma, R.
    Ives, J. R.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2010, 24 (03) : 738 - 738