Inpatient long-term video-electroencephalographic monitoring event capture audiovisual diagnostic quality

被引:1
|
作者
Terman, Samuel Waller [1 ,6 ]
O'Kula, Susanna S. [2 ,3 ]
Asmar, Melissa Marie [4 ,5 ]
Davis, Kathryn A. [5 ]
Gazzola, Deana M. [3 ]
Lesanu, Rodica [1 ]
George, Laura [1 ]
Selwa, Linda M. [1 ]
Glynn, Simon M. [1 ]
Hill, Chloe E. [1 ]
机构
[1] Univ Michigan, Dept Neurol, Ann Arbor, MI USA
[2] State Univ New York Downstate Hlth Sci Univ, Dept Neurol, Brooklyn, NY USA
[3] NYU, Dept Neurol, New York, NY USA
[4] Emory Univ, Dept Neurol, Atlanta, GA USA
[5] Univ Penn, Dept Neurol, Philadelphia, PA USA
[6] Univ Michigan, Dept Neurol, Taubman 1st Floor,Recept C,1500 Med Ctr Dr,SPC 531, Ann Arbor, MI 48109 USA
关键词
EEG; Quality; Inpatient monitoring; Seizures; EPILEPSY; SAFETY; UNITS;
D O I
10.1016/j.yebeh.2022.108947
中图分类号
B84 [心理学]; C [社会科学总论]; Q98 [人类学];
学科分类号
03 ; 0303 ; 030303 ; 04 ; 0402 ;
摘要
Objectives: Long-term video-electroencephalographic monitoring (LTVEM) represents the gold-standard method to evaluate whether events represent electrographic seizures, but limited work has evaluated the quality of inpatient event capture. We evaluated the frequency of audiovisual factors impairing the ideal electroclinical correlation of seizure-like episodes during LTVEM.Methods: We retrospectively reviewed consecutive inpatient LTVEM studies (11/2019-12/2019) from three academic epilepsy centers. We evaluated all pushbutton events for audiovisual characteristics such as whether the event was narrated, whether the patient was blocked on camera, and what diagnostic challenges impaired the electroencephalographer's ability to understand either the reason the event but-ton was pushed or clinical semiology ("electroclinical correlation"). We determined the percent of events and studies with each outcome.Results: There were 154 studies with 520 pushbutton events. The pushbutton was most commonly acti-vated by patients (41%), followed by nurses (31%) or family (17%). Twenty-nine percent of events repre-sented electrographic seizures, and 78% occurred in the Epilepsy Monitoring Unit. The reason for the push was not stated in 45% of events, and inadequate narration impaired electroclinical correlation in 19% of events. At least one relevant part of the patient's body was blocked during 12% of events, but this impaired electroclinical correlation in only 1% of events. There was at least one factor impairing electro-clinical correlation in 21% of events, most commonly due to incomplete narration (N = 99), lights off (N = 15), or blankets covering the patient (N = 15). At least one factor impaired electroclinical correlation for any event in 36% of studies.Conclusion: Audiovisual factors impairing the electroencephalographer's ability to render an electroclin-ical correlation were common, particularly related to inadequate narration from bedside observers to explain the reason for pushing the button or event semiology. Future efforts to develop targeted counter-measures should address narration challenges and improve inpatient seizure monitoring quality metrics. (c) 2022 Elsevier Inc. All rights reserved.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] SAFETY OF LONG-TERM VIDEO EEG MONITORING
    Noe, Katherine
    Drazkowski, J.
    EPILEPSIA, 2008, 49 : 54 - 54
  • [22] PSYCHOGENIC SEIZURES - DIAGNOSTIC IMPORTANCE OF VIDEO-EEG AND AMBULATORY LONG-TERM MONITORING
    Dias, A., I
    Silva, R. L.
    Moreira, A. M.
    Calado, E. P.
    Leal, A. J.
    EPILEPSIA, 2010, 51 : 120 - 120
  • [23] Long-term Quality Evaluation in OTT Video
    Satti, Shahid Mahmood
    Bitto, Roland
    Keyhl, Michael
    Obermann, Matthias
    Schmidmer, Christian
    2016 PICTURE CODING SYMPOSIUM (PCS), 2016,
  • [24] THE DIAGNOSTIC POSSIBILITIES OF MOBILE EEG LONG-TERM MONITORING
    ALEXOPOULOS, T
    ZSCHOCKE, S
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1984, 57 (02): : P32 - P32
  • [25] Event-related potentials evidence for long-term audiovisual representations of phonemes in adults
    Kaganovich, Natalya
    Christ, Sharon
    EUROPEAN JOURNAL OF NEUROSCIENCE, 2021, 54 (11) : 7860 - 7875
  • [27] Using Video Capture to Investigate the Causes of Falls in Long-Term Care
    Woolrych, Ryan
    Zecevic, Aleksandra
    Sixsmith, Andrew
    Sims-Gould, Joanie
    Feldman, Fabio
    Chaudhury, Habib
    Symes, Bobbi
    Robinovitch, Stephen N.
    GERONTOLOGIST, 2015, 55 (03): : 483 - 494
  • [28] The use of long-term video-EEG monitoring in differential diagnostic problems of childhood paroxysmal events
    Fogarasi, A
    Neuwirth, M
    Hegyi, M
    Siegler, Z
    Tegzes, A
    Herczegfalvi, A
    EPILEPSIA, 2003, 44 : 70 - 70
  • [29] Long-Term Video Electroencephalographic Monitoring in <30-Week Gestational Age Infants With High-Grade Intraventricular Hemorrhage
    Rashid, Salman
    Goyal, Monisha
    Lalor, Kathryn
    Al-Robaidi, Khaled
    Shukla, Vivek
    Rahman, Fazlur
    Ramani, Manimaran
    PEDIATRIC NEUROLOGY, 2024, 150 : 44 - 47
  • [30] Automatic Event Detection for Long-term Monitoring of Hydrophone Data
    Sattar, F.
    Driessen, P. F.
    Tzanetakis, G.
    Ness, S. R.
    Page, W. H.
    2011 IEEE PACIFIC RIM CONFERENCE ON COMMUNICATIONS, COMPUTERS AND SIGNAL PROCESSING (PACRIM), 2011, : 668 - 674