摘要
Background. Volumetric modulated arc therapy (VMAT) for treatment of non-small cell lung cancer (NSCLC) patients potentially changes the risk of radiation-induced pneumonitis (RP) compared to intensity modulated radiation therapy (IMRT) if the dose to the healthy lung is changed significantly. In this study, clinical IMRT plans were used as starting point for VMAT optimization and differences in risk estimates of RP between the two plan types were evaluated. Material and methods. Fifteen NSCLC patients prescribed 66 Gy in 2 Gy fractions were planned with IMRT and subsequently with single arc VMAT. Dose metrics were evaluated for target and lung together with population averaged dose volume histograms. The risk of RP was calculated using normal tissue complication probability (NTCP) models. Finally, applicability of the plans was tested through delivery on an Elekta accelerator. Results. When changing from IMRT to VMAT only modest differences were observed in the dose to the lung and target volume. On average, fractions of lung irradiated to doses between 18 Gy and 48 Gy were statistically signifi cant reduced using VMAT compared to IMRT. For the fraction of lung receiving more than 20 Gy the reduction was 1.2% percentage points: (range -0.6 2.6%). The evaluated toxicity were smaller with VMAT compared to IMRT, however only modest differences were observed in the NTCP values. The plans were delivered without any problems. The average beam on time with VMAT was 83 s. This was a reduction of 141 s (ranging from 37 s to 216 s) compared to IMRT. Conclusions. Using IMRT as reference for the VMAT optimization it was possible to implement VMAT in the clinic with no increase in estimated risk of RP. Thus, toxicity is not expected to be a hindrance to using VMAT and will profit from the shorter delivery time with VMAT compared to IMRT.
引用
收藏
页码:752 / 758
页数:7
相关论文
共 50 条
  • [41] Reduction in Dosimetric Impact of Motion Using VMAT Compared to IMRT in Hypofractionated Prostate Cancer Patients
    Ravindranath, B.
    Xiong, J.
    Happersett, L.
    Mageras, G.
    Zhang, P.
    Hunt, M.
    MEDICAL PHYSICS, 2016, 43 (06) : 3435 - 3435
  • [42] Clinical validation and benchmarking of knowledge-based IMRT and VMAT treatment planning in pelvic anatomy
    Hussein, Mohammad
    South, Christopher P.
    Barry, Miriam A.
    Adams, Elizabeth J.
    Jordan, Tom J.
    Stewart, Alexandra J.
    Nisbet, Andrew
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 (03) : 473 - 479
  • [43] Dosimetric Differences of VMAT, Non-Coplanar IMRT and IMPT for Treatment Planning of Glioblastoma Multiforme
    Nguyen, T.
    Algan, O.
    Ahmad, S.
    Herman, T.
    Herman, T. De La Fuente
    MEDICAL PHYSICS, 2019, 46 (06) : E330 - E330
  • [44] Deep learning-based IMRT treatment planning on synthetic-CT for ART in NSCLC-patients
    Callens, D.
    Vandewinckele, L.
    Berkovic, P.
    Maes, F.
    Lambrecht, M.
    Crijns, W.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1333 - S1334
  • [45] Comparing IMRT Versus VMAT Treatment Plan Quality for SRS Spine Patients
    Ulizio, V.
    Arora, V.
    Pearson, D.
    MEDICAL PHYSICS, 2018, 45 (06) : E331 - E331
  • [46] VMAT Reduces Moderate to High Integral Dose When Compared to Conventional IMRT for Treatment of Prostate Cancer
    Lubbe, W. J.
    Price, R.
    Ruth, K.
    Cherian, G.
    Kutikov, A.
    Chen, D.
    Uzzo, R.
    Buyyounouski, M.
    Ma, C.
    Horwitz, E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S446 - S446
  • [47] VMAT Compared to 3D-RT and Step and Shoot IMRT for Anal Cancer Pelvis Treatment
    Stieler, F.
    Lohr, F.
    Wolff, D.
    Steil, V.
    Abo-Madyan, Y.
    Wenz, F.
    Mai, S.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [48] SBRT Treatment Planning With VMAT Versus IMRT: Impact of Duodenal Sparing on Tumor Coverage in Patients With Locally Advanced Pancreatic Adenocarcinoma
    Kumar, R.
    Wild, A. T.
    Ziegler, M. A.
    Kang, J.
    Smith, K. S.
    Tryggestad, E.
    Ford, E.
    Wong, J.
    Hooker, T.
    Herman, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S783 - S784
  • [49] Evaluation of VMAT & IMRT Planning Strategies for Advanced Prostate Cancer Patients with Bilateral Hip Prostheses
    Xu, J.
    Cosely, T.
    Bouton, T.
    Zhang, B.
    Han, D.
    Zhou, J.
    Chen, S.
    MEDICAL PHYSICS, 2022, 49 (06) : E916 - E916
  • [50] Lethal pneumonitis in a phase I study of chemotherapy and IMRT for NSCLC: The need to investigate the accuracy of dose computation
    De Neve, W
    De Wagter, C
    RADIOTHERAPY AND ONCOLOGY, 2005, 75 (02) : 246 - 247