Semi-active control of seismically excited base-isolated building model with friction pendulum systems

被引:4
|
作者
Xu, Zhou [2 ]
Agrawal, Anil K. [1 ]
机构
[1] CUNY City Coll, Dept Civil Engn, New York, NY 10031 USA
[2] Weidlinger Associates INC, New York, NY 10014 USA
来源
关键词
semi-active friction control; friction base isolator; structural response control;
D O I
10.1002/stc.271
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, effectiveness of various semi-active friction control strategies in protecting the base-isolated benchmark building model with fricion pendulum systems as isolators and subject to various prescribed near-field ground motions has been investigated. These friction control strategies include semi-active discontinuous pulse filter (SADPF) controller, semi-active continuous pulse filter (SACPF) controller and visco-elastic friction (VEF) controller. In addition, the linear passive viscous (LPV) damper is also considered for cmparison. Both the SACPF and SADPF controllers are designed by using the augmented structure-pulse filter model recently proposed by the authors. Simulation results indicate that all these displacement may be accompained by an increase in superstructure response quantities. The SACPF controller is found to be the most effective among semi-active controllers, including Sample Lyapunov controller, in the sense that (i) increase in superstructure response quantities is quite minimal or these response quantities are decreased as the base displacement is reduced, (ii) there is no amplification in peak base acceleration and (iii) the control force does not have chattering-type characterostocs and control force is applied only when peak base displacement is significant. Copyright (c) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:769 / 784
页数:16
相关论文
共 50 条
  • [21] Semi-active control of friction driven systems
    Nitsche, R
    Gaul, L
    PROCEEDINGS OF IMAC-XIX: A CONFERENCE ON STRUCTURAL DYNAMICS, VOLS 1 AND 2, 2001, 4359 : 64 - 70
  • [22] Optimization of semi-active control of seismically excited buildings using genetic algorithms
    Pourzeynali, S.
    Mousanejad, T.
    Scientia Iranica, 2010, 17 (1 A) : 26 - 38
  • [23] Optimization of Semi-Active Control of Seismically Excited Buildings Using Genetic Algorithms
    Pourzeynali, S.
    Mousanejad, T.
    SCIENTIA IRANICA TRANSACTION A-CIVIL ENGINEERING, 2010, 17 (01): : 26 - 38
  • [24] Seismic protection of base-isolated structures using semi-active MR dampers
    Tse, T
    Chang, CC
    ADVANCES IN BUILDING TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 529 - 536
  • [25] Simplified Linear Static Analysis for Base-Isolated Buildings with Friction Pendulum Systems
    Liu, Tao
    Zordan, Tobia
    Briseghella, Bruno
    Zhang, Qilin
    STRUCTURAL ENGINEERING INTERNATIONAL, 2014, 24 (04) : 490 - 502
  • [26] Real-time hybrid simulation for a base-isolated building with the transmissibility-based semi-active controller
    Rabiee, Ramin
    Chae, Yunbyeong
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2022, 33 (17) : 2228 - 2240
  • [27] Application of a high-pressure gas semi-active resettable damper to the benchmark smart base-isolated building
    Leavitt, John
    Bobrow, James E.
    Jabbari, Faryar
    Yang, Jann N.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 748 - 757
  • [28] A novel robust optimum control algorithm and its application to semi-active controlled base-isolated structures
    Zhang, Dongbin
    Pan, Peng
    Zeng, Yi
    Guo, Youming
    BULLETIN OF EARTHQUAKE ENGINEERING, 2020, 18 (05) : 2431 - 2460
  • [29] A novel robust optimum control algorithm and its application to semi-active controlled base-isolated structures
    Dongbin Zhang
    Peng Pan
    Yi Zeng
    Youming Guo
    Bulletin of Earthquake Engineering, 2020, 18 : 2431 - 2460
  • [30] Seismic reduction of semi-active base-isolated structures based on multi-level fuzzy control
    Zhao D.-H.
    Li Y.-X.
    Li H.-N.
    Qian H.
    Li, Yong-Xing, 1600, Chinese Vibration Engineering Society (35): : 78 - 84