Application of a high-pressure gas semi-active resettable damper to the benchmark smart base-isolated building

被引:17
|
作者
Leavitt, John [1 ]
Bobrow, James E. [1 ]
Jabbari, Faryar [1 ]
Yang, Jann N. [1 ]
机构
[1] Univ Calif Irvine, Henry Samueli Sch Engn, Irvine, CA 92697 USA
来源
STRUCTURAL CONTROL & HEALTH MONITORING | 2006年 / 13卷 / 2-3期
关键词
resetting stiffness devices; semi-active control;
D O I
10.1002/stc.109
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
We discuss the application of a new class of low-cost and high-reliability semi-active devices for the response mitigation of structures subject to earthquakes. These devices, which manipulate stiffness rather than damping, are evaluated by the smart base-isolated benchmark building. The basic motivation, idealization as a stiffness resetting damper or device, development of control logic that ensures the semi-active property, and initial testing and validation results from recently developed prototypes are discussed. The principle idea allows the use of reliable and inexpensive hydraulic or pneumatic technologies, and leads to a decentralized and easy to implement architecture. The results from the benchmark simulations show performance competitive with well-known semi-active techniques. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:748 / 757
页数:10
相关论文
共 50 条
  • [1] Semi-active seismic response control of base-isolated building with MR damper
    Soda, S
    Kusumoto, H
    Chatani, R
    Iwata, N
    Fujitani, H
    Shiozaki, Y
    Hiwatashi, T
    SMART STRUCTURES AND MATERIALS 2003: DAMPING AND ISOLATION, 2003, 5052 : 460 - 467
  • [2] Semi-active neurocontrol of a base-isolated benchmark structure
    Lee, Heon-Jae
    Yang, Guangqiang
    Jung, Hyung-Jo
    Spencer, Billie F., Jr.
    Lee, In-Won
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 682 - 692
  • [3] Robust active control of hysteretic base-isolated structures: Application to the benchmark smart base-isolated building
    Pozo, Francesc
    Montserrat, Pere Marc
    Rodellar, Jose
    Acho, Leonardo
    STRUCTURAL CONTROL & HEALTH MONITORING, 2008, 15 (05): : 720 - 736
  • [4] Application of some semi-active control algorithms to a smart base-isolated building employing MR dampers
    Jung, Hyung-Jo
    Choi, Kang-Min
    Spencer, Billie F., Jr.
    Lee, In-Won
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 693 - 704
  • [5] A design approach for semi-active and smart base-isolated buildings
    Li, Hui
    Ou, Jinping
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 660 - 681
  • [6] Semi-active and passive control of the phase I linear base-isolated benchmark building model
    Xu, Zhou
    Agrawal, Anil K.
    Yang, Jann N.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 626 - 648
  • [7] Semi-active control of base-isolated structures
    Oliveira, F.
    Gil de Morais, P.
    Suleman, A.
    ICSI 2015 THE 1ST INTERNATIONAL CONFERENCE ON STRUCTURAL INTEGRITY FUNCHAL, 2015, 114 : 401 - 409
  • [8] Semi-active control of nonlinear smart base-isolated structures using MR damper: sensitivity and reliability analyses
    Etedali, Sadegh
    Zamani, Abbas-Ali
    SMART MATERIALS AND STRUCTURES, 2022, 31 (06)
  • [9] GA-optimized FLC-driven semi-active control for phase-II smart nonlinear base-isolated benchmark building
    Ali, Sk. Faruque
    Ramaswamy, Ananth
    STRUCTURAL CONTROL & HEALTH MONITORING, 2008, 15 (05): : 797 - 820
  • [10] Semi-Active Fuzzy Control of Tuned Mass Damper to Reduce Base-Isolated Building Response under Harmonic Excitation
    Djedoui, Nassim
    Ounis, Abdelhafid
    Mahdi, Abdeddaim
    Zahrai, Seyed Mehdi
    JORDAN JOURNAL OF CIVIL ENGINEERING, 2018, 12 (03) : 435 - 448